SUPER MICRO Computer 5037C-T user manual Security Settings, Administrator Password, User Password

Page 81

 

 

 

 

 

 

 

 

Chapter 7: BIOS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7-7

Security Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BIOS SETUP UTILTY

 

 

 

 

 

 

Main

Advanced Event Logs IPMI

Boot

Security

Exit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Password Description

 

 

 

 

Set Setup Administrator

 

 

 

If ONLY the administrator’s password is set,

 

Pasword.

 

 

 

 

 

 

 

 

 

then this only limits access to Setup and is

 

 

 

 

 

 

 

 

 

only asked for when entering Setup.

 

 

 

 

 

 

 

 

 

If ONLY the User’s password is set, then this

 

 

 

 

 

 

is a power on password and must be entered to

 

 

 

 

 

 

boot or enter Setup. In Setup the User will

 

 

 

 

 

 

 

 

 

have Administrator rights.

 

 

 

 

 

 

 

 

 

The password must be 3 to 20 characters long.

 

 

 

 

 

 

Access Level

Administrat

 

 

 

 

 

 

 

 

 

 

 

 

Administrator Password

 

 

 

 

 :

Select Screen

 

 

 

User Password

 

 

 

 

 

 

 

 

 

 

 

:

Select Item

 

 

 

 

 

 

 

 

 

 

 

 

Boot Sector Virus Protection

[Disabled]

 

Enter:

Select

 

 

 

+/- :

Change Opt.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F1 :

General Help

 

 

 

 

 

 

 

 

 

F2 :

Previous Values

 

 

 

 

 

 

 

 

 

F3 :

Optimized Defaults

 

 

 

 

 

 

 

 

 

F4 :

Save & Exit

 

 

 

 

 

 

 

 

 

ESC :

Exit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Version x.xx.xxxx. Copyright (C) 2010 American Megatrends, Inc.

 

 

 

 

 

 

 

 

 

 

 

 

If the Administrator password is defined ONLY - this controls access to the BIOS setup ONLY.

If the User's password is defined ONLY - this password will need to be entered during each system startup or boot, and will also have Administrator rights in the setup.

Passwords must be at least 3 and up to 20 characters long.

Administrator Password

Press Enter to create a new, or change an existing Administrator password.

User Password:

Press Enter to create a new, or change an existing User password.

Boot Sector Virus Protection

When Enabled, the BIOS displays a warning when any program (or virus) issues a Disk Format command or attempts to write to the boot sector of the hard disk drive. The options are Enabled and Disabled.

4-19

Image 81
Contents Super Manual Revision Release Date December 14 Preface About This ManualManual Organization Bios Advanced Chassis SetupPreface Table of Contents Chapter Advanced Chassis Setup Viii Overview Chapter IntroductionMotherboard Features Chassis Features Intel C204 Chipset System Block Diagram Headquarters Contacting SupermicroEurope Asia-PacificPage Unpacking the System Chapter System SetupRemoving the Side Covers System AccessAccessing the Inside of the System Page Chapter System Interface PowerControl Panel Button Control Panel LEDsOverheat/Fan Fail HDDElectrical Safety Precautions Chapter System SafetyGeneral Safety Precautions ESD Precautions Installing the Onboard Battery Operating PrecautionsChapter Advanced Motherboard Setup Installing the LGA1155 Processor Processor and Heatsink InstallationPage Page Thermal Grease Heatsink Fins Installing an Active Fan CPU HeatsinkPage Unplug the PWR cord Removing the HeatsinkConnecting Data Cables Connecting CablesConnecting Power Cables Connecting the Control PanelI/O Ports Front Control Panel Header Pins JF1Installing DIMMs Installing MemoryMemory Support DDR3 Unbuffered ECC Udimm MemoryPossible System Memory Allocation & Availability Installing Dimm into SlotInstalling Expansion Cards Full-Height, Full-Length Expansion Card SetupAdding PCI Expansion Cards Jumper Description Default Motherboard DetailsDescription State/Status LAN1/LAN2 Connector DescriptionATX Power Connector Connector DefinitionsProcessor Power Connector Power LEDReset Button Power ButtonOverheat OH/Fan Fail/Front UID LED Universal Serial Bus USB Serial PortsEthernet Ports Chassis Intrusion Fan HeadersATX PS/2 Keyboard and PS/2 Mouse Ports External SpeakerPower Supply I2C Connector Onboard Power LEDTrusted Platform Module Header Wake-On-LANUnit ID Switch DOM PWR ConnectorSgpio 0/1 Headers Wake-On-LAN JwolVGA Enable/Disable Jumper SettingsExplanation of Jumpers Cmos ClearLAN Port Enable/Disable PCI Slot SMB EnableWatch Dog Enable USB Wake-UpOnboard Indicators Sata Ports Sata Drive ConnectionsDriver Installation Display Screen Installing DriversSuperDoctor III Interface Display Screen Health Information SuperDoctorSuperDoctor III Interface Display Screen Remote Control Page Tools Required Chapter Advanced Chassis SetupRotating the Hard Drive Cage Rotating the Hard Drive CageRemoving and Installing 3.5 Hard Drives Removing and Installing Hard DrivesRemoving a Hard Drive from the Carrier Removing and Installing 2.5 Hard Drives Removing and Installing 2.5 Hard DrivesRemoving the 2.5 Hard Drives Installing a 3.5 Device Installing a 3.5 DeviceFan Failure System FansInstalling the Front Cooling Fan Optional Installing the Front Cooling Fan OptionalReplacing the Power Supply Power SupplyHow To Change the Configuration Data Starting Bios Setup UtilityChapter IntroductionHow to Start the Setup Utility Main SetupSystem Time/System Date ProcessorSystem Memory BOOT Feature Advanced Setup ConfigurationsProcessor & Clock Options Intel Hyper Threading Technology Power TechnologyActive Processor Cores State CoordinationChipset Configuration VT-d Active State Power ManagementPcie Maximum Payload Size PCI Express PortIDE/SATA Configuration PCIe/PCI/PnP Configuration Super IO Device Configuration Remote Access ConfigurationHardware Health Configuration Fan Speed Control ModeFan1 ~ Fan4, FanA Reading CPU Temperature Display ModeACPI Configuration Event LogsIpmi Configuration X9SCi-LN4F, X9SCA-F Only BMC SupportWait For BMC When SEL Full Erase Log Select Yes, On every reset or NoBMC Self Test Log System Event LogConfiguration Source BMC Network ConfigurationBoot Options Priority Boot SettingsBoot Option #1, Boot option #2, Boot Option #3, etc Delete Boot OptionAdministrator Password Security SettingsUser Password Boot Sector Virus ProtectionExit Options Restore DefaultsSave Changes and Exit Discard Changes and ExitSave As User Defaults Restore User DefaultsBoot Override Page Bios Error Beep Codes Appendix a Bios Error Beep CodesError Message Beep Code/LEDPage Processors Appendix B System SpecificationsWeight Appendix B System Specifications

5037C-T specifications

The Super Micro Computer 5037C-T is a robust and versatile workstation that caters to a variety of applications, particularly in fields such as data analysis, virtualization, and high-performance computing. Engineered for reliability and performance, the 5037C-T is built on Supermicro’s commitment to delivering innovative solutions tailored to meet the demands of modern computing.

One of the notable features of the 5037C-T is its support for dual Intel Xeon E5-2600 v3/v4 processors. This capability allows users to leverage advanced multi-threading technology, significantly boosting performance in resource-intensive tasks. The workstation can accommodate up to 1TB of DDR4 memory across its 16 DIMM slots, ensuring ample memory for demanding applications and complex workflows.

Storage options in the 5037C-T are extensive. It supports both SATA and SAS drives, enabling various configurations that can include a combination of traditional hard disks and high-speed solid-state drives. This flexibility allows users to optimize their storage solutions based on performance requirements and budget constraints. The system also features a hot-swappable drive bay, aiding in maintenance and upgrades.

Connectivity is another strong point for the 5037C-T. It offers multiple PCIe slots, facilitating the installation of additional graphics cards or network adapters. With support for NVIDIA GPUs, the workstation can be tailored for GPU-intensive tasks like rendering, artificial intelligence, and machine learning, making it a suitable choice for professionals in creative and scientific fields.

In terms of networking, the workstation comes equipped with dual 10 Gigabit Ethernet ports, enhancing data transfer rates and ensuring minimal latency in communication. This is particularly beneficial for environments that rely on high-speed data access and transfer, such as cloud computing or large data processing.

Cooling and thermal management are crucial components of the 5037C-T’s design. The system includes advanced cooling technologies that ensure optimal temperatures are maintained, even under heavy workloads. This not only enhances performance but also contributes to the longevity of the components.

In summary, the Super Micro Computer 5037C-T combines powerful processing capabilities, extensive memory support, flexible storage options, and robust networking features, making it a top choice for enterprises looking for a reliable and high-performance workstation. Its adaptability to various workloads and applications underscores Supermicro's commitment to providing cutting-edge solutions for today’s computing challenges.