DIP Switch Settings
The factory default settings are as follows: 1 2 3 4 5 6 7 8
ON
OFF
DIP Switch Functions
(*Note: the indicates the switch position)
SW | Function |
|
|
| ON state / OFF state | ||
1 | Hot Key Mode: <Ctrl>+<Alt>+<Shift> | ON: enabled / OFF: disabled | |||||
2 | Hot Key Mode: Double <Ctrl> |
| ON: enabled / OFF: disabled | ||||
3 | Hot Key Mode: Double <Scroll Lock> | ON: enabled / OFF: disabled | |||||
4 | Country Setting bit 1 |
|
| (see following table) | |||
5 | Country Setting bit 2 |
|
| ( | “ | ) | |
6 | Country Setting bit 3 |
|
| ( | “ | ) | |
7 | Country Setting bit 4 |
|
| ( | “ | ) | |
8 | Power Mode Setting |
|
| ON: | the switch device is always ON. | ||
|
|
|
|
| OFF: | the switch device turns ON if any connected | |
|
|
|
|
|
| host is turned ON. | |
The country code (language) settings are as follows: For Sun Microsystems plat home only | |||||||
Country Setting | SW4 | SW5 | SW6 | SW7 |
|
| |
JPN |
| ON | ON | ON | ON |
|
|
USA |
| ON | ON | ON | OFF |
|
|
GBR |
| ON | ON | OFF | ON |
|
|
GER |
| ON | ON | OFF | OFF |
|
|
FRA |
| ON | OFF | ON | ON |
|
|
ESP |
| ON | OFF | ON | OFF |
|
|
SWE |
| ON | OFF | OFF | ON |
|
|
POR |
| ON | OFF | OFF | OFF |
|
|
TPE |
| OFF | ON | ON | ON |
|
|
KOR |
| OFF | ON | ON | OFF |
|
|
ITA |
| OFF | ON | OFF | ON |
|
|
UNIX |
| OFF | ON | OFF | OFF |
|
|
NOR |
| OFF | OFF | ON | ON |
|
|
BEL |
| OFF | OFF | ON | OFF |
|
|
DEN |
| OFF | OFF | OFF | ON |
|
|
|
|
|
|
|
|
|
|
Switching the KVM While Using SUN Hosts
When using only Sun hosts, you can change KVM switches without turning off the power to a Sun host. Disconnect the connector from the KVM side only when changing them. Leave the host side connectors attached(This function is available for USB interface only).
Note: When using PC/AT hosts, if all connections are USB type, you can similarly change KVM switches without turning off the power to the hosts.