Server Technology CW-8H technical specifications Branch Circuit Protection

Page 1

Sentry : Solutions for the Data Center Equipment Cabinet

Key Features

>Remote Power Management: Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere in the world. Or, power-off unused power receptacles

>High Power Distribution: 120V, 208V, or 230V power; 20 or 30-Amp power input feed options

>High Density: Single power input feed; 8 outlets per 1U enclosure

>IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP, FTP, SNTP, Syslog, LDAP, LDAPS, TACACS and RS-232 access

>Add an Expansion Module: Daisy chain the Switched CDU Expansion Module (CW/CX) for power management of separate power circuits from a single IP address

>Environmental Monitoring: Each Switched CDU supports two temperature & humidity probes and reports conditions thru the Web interface

>SNMP Traps: Provide automated alerts for power and environmental conditions

>Input Current Monitor: Precisely measure the aggregate current draw (in amps) on each power circuit. On-site verification of the input current with the LED digital display. Remote verification via browser or serial screen.

>Power-up Sequencing: Prevent an in-rush power overload

Sentry Switched CDU

CW-8H

High-Density Power Distribution

The Switched CDU’s combine remote configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP-based alerts and email alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups.

Only the Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 branch circuit protection; SSL & SSH security; and SNMP-based input current monitoring.

Additional Benefits:

Branch Circuit Protection

The Sentry CDU Family meets the new UL 60950-1 requirement for branch circuit protection.

Attention! The Sentry CDU products meet the above criteria by providing overcurrent protection with UL-listed Bussman SC fuses for each branch circuit. The CW-8H contains fuses within the enclosure.

Input Current Monitoring

The CDU’s exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital displays on the CDU enclosure report the input current of each phase or branch circuit.

Temperature and Humidity

The Switched CDU supports two external probes. Each of these probes measure both temperature and humidity. Receive SNMP-based alert notifications when conditions exceed defined thresholds.

Image 1
Contents Branch Circuit Protection Temperature and HumidityInput Current Monitoring Accessories Power Cord OptionsAgency Approvals Communications and Security