www.seagate.com
2.9Acoustics
Drive acoustics are measured as overall
Note
For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined by the following equation:
(Number of seeks per second = 0.4 / (average latency + average access time
Table 3 Fluid Dynamic Bearing (FDB) motor acoustics
| Idle* | Performance Seek |
|
|
|
4 Disks | 2.3 bels (typical) | 2.8 bels (typical) |
(4TB) | 2.5 bels (max) | 3.0 bels (max) |
|
|
|
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and power to operational levels.
2.10Test for Prominent Discrete Tones (PDTs)
Seagate follows the
2.11Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequeny (RF) environments defined in Table 4.
Table 4 Radio frequency environments
Test | Description | Performance | Reference | |
level | standard | |||
|
| |||
|
|
|
| |
Electrostatic discharge | Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV | B | ||
|
|
|
| |
Radiated RF immunity | 80MHz to 1,000MHz, 3 V/m, | A | ||
| 80% AM with 1kHz sine |
| ENV50204: 95 | |
| 900MHz, 3 V/m, 50% pulse modulation @ 200Hz |
|
| |
|
|
|
| |
Electrical fast transient | ± 1 kV on AC mains, ± 0.5 kV on external I/O | B | ||
|
|
|
| |
Surge immunity | ± 1 kV differential, ± 2 kV common, | B | ||
| AC mains |
|
| |
|
|
|
| |
Conducted RF immunity | 150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz | A | ||
| sine |
|
| |
|
|
|
| |
Voltage dips, interrupts | 0% open, 5 seconds | C | ||
| 0% short, 5 seconds | C |
| |
| 40%, 0.10 seconds | C |
| |
| 70%, 0.01 seconds | B |
| |
|
|
|
|
Seagate Terascale HDD Product Manual, Rev. B | 14 |