Seagate ST3450856FC manual

Page 2

©2007, 2008, Seagate Technology LLC All rights reserved. Publication number: 100465943, Rev. D

August 2008

Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology LLC in the United States and/or other countries. Cheetah, SeaTools and SeaTDD are either trademarks or reg- istered trademarks of Seagate Technology LLC or one of its affiliated companies in the United States and/ or other countries. All other trademarks or registered trademarks are the property of their respective own- ers.

One gigabyte, or GB, equals one billion bytes when referring to hard drive capacity. Accessible capacity may vary depending on operating environment and formatting. Quantitative usage examples for various applications are for illustrative purposes. Actual quantities will vary based on various factors, including file size, file format, features and application software. Seagate reserves the right to change, without notice, product offerings or specifications.

Image 2
Contents ST3146356FC ST3450856FCST3300656FC Page Contents Installation Physical/electrical specificationsDefect and error management Interface requirementsSeagate Technology support services Cheetah 15K.6 FC Product Manual, Rev. D Scope Model Number Full Disk Encryption FDECheetah 15K.6 FC Product Manual, Rev. D Electromagnetic compatibility Applicable standards and reference documentationStandards Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Reference documents Ncits TR-20Cheetah 15K.6 FC Product Manual, Rev. D General description Standard features Reliability Media descriptionPerformance Formatted capacitiesFactory-installed options User-installed accessoriesSeek performance characteristics Performance characteristicsInternal drive characteristics Access timeStart/stop time Format command execution time minutesGeneral performance characteristics 176 144 100Caching write data Prefetch/multi-segmented cache controlCache operation Prefetch operation Recoverable Errors Reliability specificationsError rates Unrecoverable ErrorsInterface errors Reliability and serviceSeek errors Preventive maintenancePerformance impact 4 S.M.A.R.TControlling S.M.A.R.T MillisecondsPredictive failures Temperature Log Page 0DhDetermining rate Thermal monitorDST failure definition State of the drive prior to testingDrive Self Test DST ImplementationExtended test Function Code 010b Short and extended testsShort test Function Code 001b Log page entriesProduct repair and return information Product warrantyShipping Cheetah 15K.6 FC Product Manual, Rev. D DC power requirements Physical/electrical specificationsAC power requirements ST3450856FC DC power requirements Gbit Amps ST3450056FC DC power requirements Gbit AmpsST3300656FC DC power requirements Gbit Amps ST3300056FC DC power requirements Gbit AmpsST3146356FC DC power requirements Gbit Amps ST3146756FC DC power requirements Gbit AmpsConducted noise immunity General DC power requirement notesPower sequencing Current profilesTypical ST3450856FC current profiles Typical ST3450056FC current profiles Typical ST3300656FC current profiles Typical ST3300056FC current profiles Typical ST3146356FC current profiles Typical ST3146756FC current profiles Power dissipation 450GB models300GB models 146GB models TemperatureEnvironmental limits Relative humidity Effective altitude sea levelShock Package size Packaged/product weight Drop heightShock and vibration Recommended mounting Acoustics Air cleanlinessVibration Corrosive environmentRoHS compliance statement Mechanical specifications Mounting configuration dimensionsDrive error recovery procedures Defect and error managementDrive internal defects/errors Page FC-AL system errors Background Media ScanIdle Read After Write Media Pre-ScanDeferred Auto-Reallocation Drive orientation InstallationDrive ID/option selection CoolingDrive mounting GroundingPage Cheetah 15K.6 FC Product Manual, Rev. D Link services supported Type of frame FC-AL featuresFibre Channel link service frames Interface requirementsFC Scsi FCP response codes Function name Response code Fibre Channel task management functionsFibre Channel task management responses Fibre Channel port login NPort login Plogi payload BytesNPort Login Accept ACC payload Bytes Fibre Channel port login acceptFibre Channel Process Login Process Login Plri payloadProcess Login Accept ACC payload Bytes Fibre Channel Process Login AcceptFibre Channel fabric login Fabric Login Flogi payload BytesFibre Channel fabric accept login Fabric Login Accept ACC payload BytesFibre Channel Arbitrated Loop options Scsi commands supportedDual port support FC-AL options supportedSupported commands Cheetah 15K.6 FC Product Manual, Rev. D Cheetah 15K.6 FC Product Manual, Rev. D Supported commands Cheetah 15K.6 FC inquiry data Bytes Data hex Mode Sense dataInquiry data Page Mode Data Header 000000 Cheetah 15K.6 FC Product Manual, Rev. D Supported Feature or condition Miscellaneous operating features and conditionsMiscellaneous features Miscellaneous statusPhysical description Physical characteristicsFC-AL physical interface Pin descriptions Connector requirementsElectrical description FC-AL transmitters and receivers FC-SCA pin descriptions Pin Signal name Signal typePin Signal name Signal type Power Fault LED OutMotor start controls Enable port bypass signalsActive LED Out Parallel Enclosure Services Interface ESI 11 SEL6 through SEL0 ID linesHex Dec SettingArbitrated loop physical address Alpa values Device control codes Signal characteristicsTTL input characteristics FC Differential input LED driver signalsFC Differential output Receive eye diagram Eye diagram data values Link rate GHz Cheetah 15K.6 FC Product Manual, Rev. D Presales Support Seagate Technology support servicesInternet Technical SupportData Recovery Services Call CenterToll-freeDirect dialFAX Warranty ServiceData Recovery Services Authorized Service Centers Index NumericsFC-AL Flogi Plogi Page See also cooling
Related manuals
Manual 94 pages 61.27 Kb