CEM/B/040 Rev C
Product Highlights
Connect to existing read head technology
The DCM 150 is suitable for installations where customers want to connect existing read head technology to any of CEM’s intelligent controller products like webEntry or the S9032/ S9064 with AC2000 SE. Unlike the CEM range of card readers the DCM 150 does not provide local database support for
Ease of Installation
Visual confirmation of board, relay and comms transmit/receive
status is provided via LEDs allowing easy installation and simplifying the diagnostic process. An onboard LED provides visual alerts to help when a number of DCM’s are banked in close proximity to one another.
High quality connectors simplify the installation process and allow simple drop in replacement in the event of hardware failure. Board configuration is achieved via a small number of jumpers and requires no specialist tools.
TECHNICAL SPECIFICATIONS
Physical |
| Inputs continued | Break Glass Sense |
|
|
| Fire Alarm Sense |
Size |
|
| Power Fail |
- Board Only | 180 x 120 x 20mm |
| Tamper |
| (7.1” x 4.7” x 0.8”) |
| Battery Low (reported internally) |
- Enclosure | 460 x 250 x 90mm |
| Dedicated Power Fail Input |
| (18” x 10” x 3.5”) |
| * = 4 state tamper protected inputs |
Weight |
| Outputs | Two 12V or 24V open collector outputs |
- Board Only 0.1Kg |
|
| limited to 1.5A |
- Enclosure 5.00kg |
|
| (Door Lock and External Sounder) |
Housing | Wall mounting 1.2mm steel enclosure |
| Two Relays rated at 35V@2A |
Colour | Grey | Reader capacity | 2 Weigand/Mag Stripe interfaces (data/ |
Power |
|
| data, clock/data) |
- Board Only: |
| Configuration | Operational parameters are downloaded |
- Voltage | 11 – 15Vdc | from host computer. |
|
- Current |
| Communication Interface | |
Consumption | 300mA (excluding locks | ||
| and heads) | To Readers | Weigand/Mag Stripe interface (data/data, |
Enclosure: |
| ||
Voltage |
| clock/data) | |
Current |
| - Connection | 2 part screw terminals |
Consumption | 450mA (excluding locks and heads) | To System Host | RS485 multidrop cable runs using copper |
Backup Battery | Integral charging circuit provided with |
| wire with maximum length of 1.2km |
| enclosure and space battery |
| without repeater |
| (Battery not supplied). | - Connection | 2 part screw terminals |
Environmental |
| Product Codes |
|
- Temperature |
| ||
- Humidity | 95% non condensing | DCM/150/105 | DCM 150 (Board Only) |
LED Indicators | Power, Link to host, Comms Tx/Rx, Fault / | ||
| Tamper, Lock and Relay Status | DCM/150/101 | DCM 150 (Includes enclosure, board & |
|
|
| power supply/battery charger) |
Functionality |
|
|
|
Inputs | * Door Position |
|
|
| * Lock Status |
|
|
| * Exit Push Button |
|
|
| * General Purpose |
|
|
Product specifications and availability is subject to change without notice. Certain product names mentioned herein may be trade names and/or registered trademarks of their companies.
CEM Systems Ltd Unit 4 Ravenhill Business Park Ravenhill Road Belfast BT6 8AW Northern Ireland | www.cemsys.com |
Tel: +44 (0)28 9045 6767 Fax: +44 (0)28 9045 4535 email: cem.sales@tycoint.com |