DP6-MLPS1
Power Supply
M4533-0607
INSTRUCTION
SHEET
Shop online at: omega.com
For latest product manuals: omegamanual.info
| PROVIDES +12 VDC POWER FOR THE DP63000x SERIES | |
UL Recognized Component, | 12 VDC OUTPUT @ 400 mA | |
File # E313607 | ||
| ||
| EASILY ATTACHED TO BACK OF DP63000x |
DESCRIPTION
The Model
Caution: The maximum output current of the
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
CAUTION: Read complete instructions prior | CAUTION: |
to installation and operation of the unit. | Risk of electric shock. |
|
|
DIMENSIONS In inches (mm) |
SPECIFICATIONS
1.POWER REQUIREMENTS:
2.POWER OUTPUT: +16 VDC max @ 4 mA
11.5VDC min @ 400 mA
3.ENVIRONMENTAL CONDITIONS:
Operating Temperature: 0 to 60°C
Storage Temperature:
Operating and Storage Humidity: 85% max.
Altitude: Up to 2000 meters
4.CERTIFICATIONS AND COMPLIANCES: SAFETY
UL Recognized Component, File # E313607, UL
Recognized to U.S. and Canadian requirements under the Component Recognition Program of Underwriters Laboratories, Inc.
Output meets Class 2 power requirements per UL 1310.
IEC
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for Measurement, Control and Laboratory use.
Immunity to Industrial Locations: |
| ||
Electrostatic discharge | EN | Criterion A | |
|
| 4 kV contact discharge | |
|
| 8 kV air discharge | |
Electromagnetic RF fields | EN | Criterion A | |
|
| 10 V/m | |
Fast transients (burst) | EN | Criterion A | |
|
| 2 kV power | |
|
| 1 kV signal | |
Surge | EN | Criterion B | |
|
| 1 kV | |
|
| 2 kV | |
|
| 1 kV signal | |
RF conducted interference | EN | Criterion A | |
|
| 3 V/rms | |
Voltage dip/interruptions | EN | Criterion A | |
Emissions: |
| 0.5 cycle | |
EN 55011 | Class B | ||
|
Notes:
1. Criterion A: Normal operation within specified limits.
2. Criterion B: Temporary loss of performance from which the unit self- recovers.
5. CONSTRUCTION: High impact black plastic. Mounting hardware included. Installation Category II, Pollution Degree 2.
6. CONNECTION: Two position terminal block which accepts one 14 AWG wire (torque terminal screws to 5
7. WEIGHT: 2 oz (47 g)
LP0696X