Omega DP6-MLPS1 instruction sheet Description, Safety Summary, Specifications

Page 1

DP6-MLPS1

Power Supply

M4533-0607

INSTRUCTION

SHEET

Shop online at: omega.com e-mail: info@omega.com

For latest product manuals: omegamanual.info

 

PROVIDES +12 VDC POWER FOR THE DP63000x SERIES

UL Recognized Component,

12 VDC OUTPUT @ 400 mA

File # E313607

 

 

EASILY ATTACHED TO BACK OF DP63000x

DESCRIPTION

The Model DP6-MLPS1 is a +12 VDC power supply designed to attach to the rear of the DP63000x Series. The DP6-MLPS1 can be powered from an 85- 250 VAC source.

Caution: The maximum output current of the DP6-MLPS1 is 400 mA. Check the specifications of the specific counter(s)/indicators(s) and sensors(s) being used to ensure that total current requirements do not exceed 400 mA.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

CAUTION: Read complete instructions prior

CAUTION:

to installation and operation of the unit.

Risk of electric shock.

 

 

DIMENSIONS In inches (mm)

SPECIFICATIONS

1.POWER REQUIREMENTS: 85-250 VAC, 50/60 Hz, 14 VA.

2.POWER OUTPUT: +16 VDC max @ 4 mA

11.5VDC min @ 400 mA

3.ENVIRONMENTAL CONDITIONS:

Operating Temperature: 0 to 60°C

Storage Temperature: -30 to 75°C

Operating and Storage Humidity: 85% max. (non-condensing) from 0°C to 50°C.

Altitude: Up to 2000 meters

4.CERTIFICATIONS AND COMPLIANCES: SAFETY

UL Recognized Component, File # E313607, UL 61010-1, CSA C22.2 No. 61010-1

Recognized to U.S. and Canadian requirements under the Component Recognition Program of Underwriters Laboratories, Inc.

Output meets Class 2 power requirements per UL 1310.

IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use, Part 1.

ELECTROMAGNETIC COMPATIBILITY

Emissions and Immunity to EN 61326: Electrical Equipment for Measurement, Control and Laboratory use.

Immunity to Industrial Locations:

 

Electrostatic discharge

EN 61000-4-2

Criterion A

 

 

4 kV contact discharge

 

 

8 kV air discharge

Electromagnetic RF fields

EN 61000-4-3

Criterion A

 

 

10 V/m

Fast transients (burst)

EN 61000-4-4

Criterion A

 

 

2 kV power

 

 

1 kV signal

Surge

EN 61000-4-5

Criterion B

 

 

1 kV L-L,

 

 

2 kV L&N-E power

 

 

1 kV signal

RF conducted interference

EN 61000-4-6

Criterion A

 

 

3 V/rms

Voltage dip/interruptions

EN 61000-4-11

Criterion A

Emissions:

 

0.5 cycle

EN 55011

Class B

 

Notes:

1. Criterion A: Normal operation within specified limits.

2. Criterion B: Temporary loss of performance from which the unit self- recovers.

5. CONSTRUCTION: High impact black plastic. Mounting hardware included. Installation Category II, Pollution Degree 2.

6. CONNECTION: Two position terminal block which accepts one 14 AWG wire (torque terminal screws to 5 inch-lbs. [0.56 N-m]).

7. WEIGHT: 2 oz (47 g)

LP0696X