Appendix D – Ground Loop Phenomenon

Appendix D - Ground Loop Phenomenon

What is Ground Loop?

Ground loop Phenomenon occurs when two (or more) pieces of equipment are connected together with a common ground and a different ground potential exists at each location. This current can cause the connected equipment to experience noise that in turn causes data transmission errors. In the extreme this ground current can cause equipment malfunction or even destruction.

Cabling Recommendations

When connecting the OMG-CONV-485-ISOIin a RS-485 network, care should be taken that both ends of the network are not isolated from ground (see Figure 8). This “floating” ground condition could cause the capacitive or inductive coupling of voltages that will cause a break down in the DC to DC converter circuit or in the opto-isolator circuit. This condition will cause data errors and possibly destruction of the receiver circuit.

Isolation Barrier

A

Isolated Adapter

DATA+

DATA-

Ground

B

Non

Isolated

Adapter

Figure 9 – OMG-CONV-485-ISOIcabling example

OMG-CONV-485-ISO

Page 16

Image 20
Contents User’sGuide Canada MexicoBenelux Czech RepublicContents Figures Factory Default Settings IntroductionOverview What’s IncludedCard Setup RS-485 Enable ModesCommunication Mode Examples Dip switch SW1 Dip switch SW1, RS-422Line Termination and Receiver Echo Off/On FunctionElectrical Interface Examples Dip switch SW2 RS-422 with Termination and Receiver EchoOperating System Installation For Windows Users RS-485 Two-Wire and RS-485 Four-Wire Slave Installation Other Operating Systems System Installation Please NoteRS-422/485 Pin Assignments 6 Position Screw Terminal Connector Pin Assignments RS-232 Signals DB-25 FemaleTechnical Description Specifications Environmental SpecificationsPhysical Dimensions ManufacturingAppendix a Troubleshooting Appendix B How To Get Assistance RS-422 Appendix C Electrical InterfaceRS-232 RS-485 What is Ground Loop? Appendix D Ground Loop PhenomenonCabling Recommendations Isolated AdapterAsynchronous Communications Bit Diagram Appendix E Asynchronous Communications688 Appendix F Silk-ScreenAppendix G Compliance Notices WARRANTY/DISCLAIMER Temperature