Omega Vehicle Security DAQ-16 Start of Conversion Register, 3 DAC0 Register, 4 DAC1 Register

Page 27

4.1.2Start of Conversion Register

The start of conversion register is 16-bit write only and performs two functions:

1.When configured for internal triggering, writing a "0" to this register generates the software trigger, starting the data conversion process.

2.Writing a "0" to this register at any time resets the VALID bit in the control word register. This allows the VALID bit to be reset at any time during the conversion

process or before the event of an external trigger.

4.1.3DAC0 Register

An output to this register causes the lower twelve bits of data to be converted to an analog output on D/A converter channel 0. The four most significant bits of data are ignored. This register is 16-bit write only.

4.1.4DAC1 Register

An output to this register causes the lower twelve bits of data to be converted to an analog output on D/A converter channel 1. The four most significant bits of data are ignored. This register is 16-bit write only.

The remaining four registers are contained in an 8254 counter/timer.

4.1.5Clock Rate Register (low word)

The low word of the clock divider is contained in counter 0 of an 8254 counter/timer. The output of this counter is cascaded into the input of counter 1 to produce a 32-bit timer. Mode 2 must be selected for counter 0 with a minimum count of 2. This register is 8-bit read/write.

4.1.6Clock Rate Register (high word)

The high word of the clock divider is contained in counter 1 of the 8254 counter/timer. Mode 2 must be selected for counter 1 with a minimum count of 2. This register is 8-bit read/write.

4.1.7Multi-Function Timer Register

The multi-function timer is implemented using counter 2 of the 8254 counter/timer. Mode 2 must be selected for this timer with a minimum count of 2. This register is 8-bit read/write.

4.1.88254 Control Word/Status Register

This register is used to program the mode and report the status of the 8254 counter/timer. This register is 8-bit read/write.

DAQ-16 Users Manual

27

Image 27
Contents 15,1*,1 WARRANTY/DISCLAIMER Servicing North America For immediate technical or application assistanceServicing Europe Page Standards to which Conformity is Declared Manufacturers NameManufacturers Address Application of Council DirectiveTable of Contents List of Figures and Tables Introduction InstallationDAQ-16 Specifications Maximum Input Voltage Amplifier Range Analog to Digital ConverterJumper J7 Configuration Volt range Unipolar Bipolar Binary 2s complement Voltage Binary ’s Complement Digital to Analog Converters Gain = Digital Input/OutputChannel Bipolar UnipolarI/O Base Address Selection Base AddressClock Selection Internal Clock External Clock Start of Conversion Trigger Selection10. Jumpers J8 and J9 Configuration Direct Memory AccessExternal Interrupt InterruptsExternal Connections Page Control Word Register Register DescriptionCHSL2 CHSL1 CHSL0 4 DAC1 Register Multi-Function Timer RegisterStart of Conversion Register 3 DAC0 RegisterProgramming the 8254 Counter/Timer Counter 1 Clock rate register high word Version January 28