Multi-Tech Systems LED Indicators, Power Supply LED, Adjustment of the PS9600 Power Supply

Page 16

PS9600 Power Supply User Guide

Introduction

This chapter provides information needed to identify and fix problems with the PS9600 power supply module. Problems can be observed on the CommPlete system’s front panel LEDs, the control PC’s screen, or via audio alarm or alarm report. In addition, problems can be found when performing the Diagnostic Tests documented elsewhere in the CommPlete Communications Server User Guide.

LED Indicators

The CommPlete Communication Server’s front panels contains the following indicators.

MR9600 controller LEDs.

Modem card LEDs. The number of LEDs on your modem card may vary, depending on the type of modem card in your chassis. Please refer to your modem’s user guide for LED descriptions.

PS9600 power supply LED.

The PS9600 power supply LED is described below. Each of the other LED indicators is described in the applicable manual.

Power Supply LED

This LED goes out if one of the PS9600 power supply outputs goes low or fails altogether. In normal operation it is lit. The recovery procedure to be used depends on whether the CommPlete chassis has one or two PS9600 power supplies installed.

Indication:

LED is on (either one or two PS9600s installed).

Meaning:

The power supply (or supplies) are operating properly.

Recovery:

No action required.

Indication:

LED is off (one PS9600 installed).

Meaning:

At least one of the outputs is low or out.

Recovery:

Turn off the power supply, remove it, and check the fuse. Replace the fuse if it is blown;

 

call Technical Support if the fuse is good (Chapter 5).

Indication:

LED is off (two PS9600s are installed).

Meaning:

At least one of the outputs is low or out. Power is being supplied by the second PS9600.

Recovery:

Turn off the PS9600 that has the LED off, and remove the PS9600. Replace the fuse if it is

 

blown; call Technical Support if the fuse is good (Chapter 5).

Adjustment of the PS9600 Power Supply

For optimal operation of the CommPlete Communications Server, the 5 V output of the PS9600 power supply should be adjusted to 5.1 VDC. The 5-volt test points are located on the back of the chassis between the power supply fans.

10

CommPlete Communications Server

Image 16
Contents PS9600 Power Supply User Guide Page Federal Communications Commission Statement CommPlete Communications Server Table of Contents CommPlete Communications Server Introduction Introduction FeaturesDescription Technical Specifications Manual OrganizationPage Installation Pre-Installation Notes Installation ProcedureOperation Power Switch Power IndicatorSolving Problems Power Supply LED LED IndicatorsAdjustment of the PS9600 Power Supply Important Safety Considerations Fuse ReplacementInsertion and Removal of a Power Supply Safety Disconnect DeviceIndex PS9600 Power Supply User Guide