Float Actuated Oil Level Swichgage® instrument
Revised
Catalog Section 15
L100
L120
L127/L128
For Small Engines and Pumps
■See Oil Level and Condition Without Shutting Down
■Shutdown or Alarm on Low Lube Level
■Adjustable Limit Switch for Alarm and/or Shutdown
■Save on Reduced Downtime and Repair Costs
■ Simple Installation | ** |
|
Description
These float actuated Oil Level Swichgage instru- ments are a combination oil level sight gage and adjustable, low and/or high limit switch. The limit switches are normally open during opera-
Application
The level instruments described above can be used on a variety of crankcases, pump gearcases, or oil
L100†: Small engines and pumps with
L100W†: Small engines and pumps with vented crankcase.
L120†: Machined surface on crankcase such as Witte,
L127: Machined surface on crankcase, specifi- cally,
L128: Machined surface on crankcase, specifical- ly, Arrow and Continental Emsco/Climax.
Specifications
■Maximum Pressure Rating (all models): 30 psi (207 kPa) [2.07 bar]
■L100 and L100W Case: Die cast aluminum Float: Brass
Rating: 2 A @ 30 VAC/DC
Vent Fitting: 1/4 in. (6 mm) tube x 1/8 NPT
Inlet Fitting: Hex Nipple 1/4 NPT
Hardware (shipped loose) L100:
•Copper Tubing: 1/4 x 48 in. dia. (6 mm x 1.2 m)
•Reducer Bushing: 1/2 NPT x 1/4 NPT
•Close Nipple: 1/2 NPT
•Tee: 1/2 NPT, black pipe
•Wire: 16 AWG x 24 in. (1.5 mm2 x 610 mm)
L100W:
•Vent Tube: 1/4 x
•Reducer Bushing: 3/4 NPT x 1/4 NPT
•Close Nipple: 3/4 NPT
•Tee: 3/4 NPT, black pipe
•Wire: 16 AWG x 24 in. (1.5 mm2 x 610 mm)
■L120
Case: Cast Aluminum
Float: Brass
Rating: 2 A @ 30 VAC/DC
Mounting Bolts:
■L127 and L128
Case: TROGAMID® Nylon
Float: Brass
Rating: 2 A @ 30 VAC/DC
Wire: 16 AWG x 48 in. (1.5 mm2 x 1.2 m)
Mounting Bolts:
•L127:
•L128:
Warranty
A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm
†Models available with high and low options. See How to Order on reverse side.
**Products covered by this bulletin comply with EMC Council directive 89/336/EEC regarding electromagnetic compatibility except as noted.