Murphy Annunciators and Magnetic Switches manual Vac/Vdc

Page 3

 

 

 

 

518PH Aallows for SWICHGAGE® and/or

 

 

 

 

N.C. contacts to be wired “Closed Loop” (in

 

 

 

 

series). Any contact open or SWICHGAGE®

 

 

 

 

contact close in the circuit shunt trips the

 

 

R

 

518PH. Specify 12 or 24 VDC. Contacts 10

G

NC

SW1

SW2 B

amps 24V. 14 amp fuse.

 

 

 

 

518APH Allows for SWICHGAGE® and/or

 

 

 

 

N.C. contacts to be wired “Closed Loop” (in

 

 

 

 

series). Any contact open or SWICHGAGE®

 

 

 

 

contact close in the circuit shunt trips the

 

 

 

 

518APH. Specify 12 or 24 VDC. Contacts 10

 

 

 

 

amps 24V. 14 amp fuse.

 

 

R

 

 

GNO

NC

SW1 SW2 B

518E Same as 518APH but recommended

 

 

 

 

for high vibration application where nuisance

 

 

 

 

shutdowns typically occur due to higher than

 

 

 

 

normal vibrations (ie. wood chippers) 12 Volt

 

 

 

 

only.

520APH Same as 518APH except with 30

 

 

second time delay before trip on one SWICH-

 

 

GAGE® contact input but immediate trip on the

 

 

second SWICHGAGE® contact input. Typical

 

TD

use is for immediate stop of engine from oil

 

R

pressure or coolant temperature, but delayed

GNO NC

SW1 SW2 B

shutdown from alignment switches on center

 

 

pivot irrigation system. Specify 12 or 24 VDC

 

 

and length of time delay. Time delays are

 

*

available from 5 to 120 seconds. Contacts 10 amps

 

24 V. 14 amp fuse.

 

 

 

 

 

 

 

 

 

 

 

 

 

760A/760AF/761APH Use for distribu-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tor ignition or diesel. Time delay lockout of

 

 

 

 

 

 

 

 

 

 

SWICHGAGE® contacts on start-up only; cus-

 

 

 

 

 

 

TD

 

 

 

 

 

 

 

 

 

 

 

 

tomer wired for delayed or immediate trip on

 

 

 

 

 

 

 

 

 

 

shutdown. Breaks and makes circuits when

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tripped. 760A resets automatically when the

 

 

 

 

 

 

 

 

 

 

 

G NO NC

 

S B

shutdown signal is removed or power is

 

 

 

 

 

 

 

 

 

 

 

 

removed. 761APH has manual reset. 760AF is

 

 

 

 

 

 

 

 

 

 

760A with inline fuse. Must specify 12 or 24

 

 

 

 

 

*

 

VDC, and length of time delay. Optional time delays: 15, 30

 

 

 

 

 

 

(standard) or 60 seconds. Contacts 10 amps 24 V. 14 amp fuse. Models 760A and 761APH carry the CE mark.

NOTE : The 760A cannot be adequately protected by a circuit breaker in a dead short condition with a battery as the power source. The circuit breaker will take a finite amount of time to react, during which time the circuit board of the 760A will be dam- aged beyond repair. Fuses are the optimal method for protecting the 760A.

 

 

 

822PH Used in Murphy TR-assemblies as

 

 

 

master disconnect. 24 VAC coil energizes

 

 

 

when SWICHGAGE® contact closes to

 

 

 

ground; breaks and makes circuit when

 

 

 

tripped. Manual reset.

NO

NC

C

SW

M4264 Series Detects loss of

 

 

 

 

 

magneto/CD ignition output and transfers con-

 

 

 

 

 

tacts for customer use. Contacts 10 amps; 48

 

 

 

 

 

VAC/VDC.

Sensing

 

 

 

M42641CD transfers SPDT dry contacts when

 

 

 

Circuit

 

 

 

 

tripped.

 

 

 

 

 

BY

IGN

NO

NC

IGN

C

G

NC

SW

C

521PH Use with N.C. SWICHGAGE® or switches to ground magneto or CD ignition when tripped. Trip coil energized to run, de- energized to shutdown when N.C.

contacts open. Specify 12 or 24* VDC. Contacts 10 amps 24 V.

G

NO

NC

S

B

R129A A SPDT relay with 10 amp dry contacts. Specify 12 or 24 VDC. Contacts 10 amps 24 VDC. 14 amp fuse.

6

1

2

3

4

5

MS2111 Replaces 221PH w/72 ohm coil. Used with NICS-78 non-incendive control system. Service part only.

ETS30S All solid-state time delay for energized to stop circuits such as solenoids. When a shutdown signal is received, the ETS30S applies power to the shutdown device for 30 seconds and then disconnects the power. Input power 12 or 24 VDC.

* Complies with EMC Council directive 89/336/EEC regarding electromagnetic compatibility.

78793B page 3 of 4

Image 3
Contents Features DescriptionApplication 117/117PH Use to shutdown 12V thru TletaleVAC/VDC Configurations Available AccessoriesETS30S