Bryston Front Panel, 6BSST THREE CHANNEL POWER AMPLIFIER, SST POWER switch, LED Indicators

Page 6
Front Panel

6BSST THREE CHANNEL POWER AMPLIFIER

Front Panel

1. 'SST POWER' switch

The front panel label 'SST POWER', is a touch sensitive membrane switch used to apply or remove a/c line power to the 6BSST circuitry. Push firmly the center of the switch until the power-up sequence begins. Push again and the 6BSST will power-down. ( Note: the rear circuit breaker must be on for the 6BSST to power-up)

2. LED Indicators

Each 6BSST channel has a LED indicator to monitor the following channel conditions:

UNLIT

-

indicates channel has no power.

RED -

 

indicates channel is muted (power-up-down sequence)

GREEN

-

indicates channel operation is normal.

FLASHING RED - indicates channel clipping.

ORANGE -

indicates channel thermal shutdown.

Power up sequence

After pushing the 'SST POWER' switch, each channel led will turn from unlit to red (mute). When the power supplies have stabilized the channel will come out of mute and the led will change to green (normal operation).

Unlit led ( No power )

The 6BSST channel led when unlit indicates no A/C mains power is present at the channel. If all channel led indicators are unlit the 6BSST probably needs only to be powered on. A single led not lighting possibly indicates blown channel fuses. When checking fuses switch off the circuit breaker on the rear panel, or unplug the power cord. Use only the specified quick-acting 4 amp 250V 5mm x 20mm fuses. See page 6 for the fuse locations.

Clipping ( flashing red )

Clipping occurs when the channel output level no longer can follow the level increase at the input (Over driven outeeput condition). When a 6BSST channel is driven into clipping the channel led will change from green to red then back to green when the level is reduced ( Flashing Red ). Momentary clipping can be tolerated, however it indicates that maxi- mum un-distorted power has been surpassed and potential speaker damage may result if overload conditions persist. Any amplifier that is constantly operated into clipping indicates a more powerful amplifier is needed for that application.

Thermal Shutdown ( orange )

The 6BSST channel has thermal shutdown circuitry to prevent damage due to overheating.

Should thermal shutdown occur, the channel will mute, and the channel led will turn orange indicating this condition. When the channel has cooled to a safe operating condition the channel will return to normal operation.

Persistent Thermal shutdown indicates steps need to be taken to increase airflow across the channel or channels heat sink. ( Also see installation section on ventilation ).

4

Image 6
Contents Instructions For Bryston SST Series Amplifiers Model 6BSSTPower Control Panel Table of ContentsRear Panel Input Settings/Connections 5.1 Typical Home Theatre SetupA/C power Warranty see back page for detailsWiring the 6BSST also see rear panel description IntroductionRear Panel Input / Output Connections 6BSST THREE CHANNEL POWER AMPLIFIER 6. Output binding posts & polarity7. Rear Handle Page 2 Fig 1. SST POWER switch Front Panel6BSST THREE CHANNEL POWER AMPLIFIER 2. LED IndicatorsControl Voltage equipped source Power Control Panelfig W 4 to 12v ac or dcDO NOT REMOVE Rack Mounting InstructionsREMOVE 6-32SCREWS FROM THIS SIDE REMOVE 3-32SCREWS FROM THIS SIDEPRECAUTION Typical 5.1 Home Theatre SetupPowered Subwoofer Left Front6BSST THREE CHANNEL POWER AMPLIFIER Typical Band-passNoise Typical THD+N Harmonic ContentPower supply artifacts are all below -95dBu balanced input with 23dB gain shown8 ohm 300w .01dB 20Khz 4 ohm 500w .1dB 20Khz Typical Phase ResponseTypical Frequency Response 4 ohm 600w 8 ohm 300w4v balanced input shown Typical THD+N SweepTypical IMD Sweep 4 ohm 600w 8 ohm 300w8 ohm reference Damping FactorTypical Crosstalk channel 2 reading with channels 1 & 3 driven toTechnical Specifications WeightNEWPORT VERMONT. U.S.A. PHONE: 802- 334-1201FAX: BRYSTON 20 -YEARWARRANTYBRYSTON SERVICE U.S.A. 70 COVENTRY ST SUITE #5 CHECK OUR WEB SITE AT www@bryston.ca