LevelOne POH-0850TX user manual System Setup & Control interface

Page 12

device current configuration to the utility system and enable auto refresh function. Port Specific Control: each port specific function control and relate parameters

display.

Parametric Information: port parameters information display.

System Setup & Control

Master Enable: Enable/Disable the control of GUI. You must enable this item to do the port controlling.

Calibrate System: when the system can’t do the port controlling, please remove the PD device and enable this function to calibrate internal system.

PD Discovery R (ohms): set the PD resistor value range for the system detecting. The default value range is 19000~26500. You can adjust the upper and lower limit value when the system can’t detect the PD resistor in the default range. Please refer to the “Discover R (ohms)” value in Parametric Information section to adjust the upper and lower limit value. After you have adjusted the upper or lower limit value, please unplug and then plug in the PD device.

Figure 4-2. System Setup & Control interface

10

Image 12
Contents POH-0850TX Contents Features IntroductionPackage Contents Physical Dimension LED IndicatorsHardware Description Front PanelPower On Status Color Description PowerPower Off Rear PanelNetwork Application PC orSoftware Utility Installation Page Remove/ Add application Power Over Ethernet Connecting to PoE GUI ManagementSystem Setup & Control System Setup & Control interfaceDevice Setting System InformationDevice Setting interface Power Device Classification Current Usage Power W Port Specific ControlPort Specific Control interface Class Usage Maximum power of levels at Parametric InformationTechnical Specification Power consumption WeightOperating environment Operating Temperature Humidity TemperatureAppendix Console Port Pin AssignmentsDTE Pin # RXD