LevelOne GSW-2476 user manual CE Mark Declaration of Conformance for EMI and Safety EEC

Page 4

COMPLIANCES

CE Mark Declaration of Conformance for EMI and Safety (EEC)

This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the compliance with these Directives, the following standards were applied:

RFI Emission:

• Limit class A according to EN 55022:1998

 

• Limit class A for harmonic current emission according to

 

EN 61000-3-2/1995

 

• Limitation of voltage fluctuation and flicker in low-voltage supply

 

system according to EN 61000-3-3/1995

Immunity:

• Product family standard according to EN 55024:1998

 

• Electrostatic Discharge according to EN 61000-4-2:1995

 

(Contact Discharge: ±4 kV, Air Discharge: ±8 kV)

 

Radio-frequency electromagnetic field according to EN 61000-4-3:1996

 

(80 - 1000 MHz with 1 kHz AM 80% Modulation: 3 V/m)

 

• Electrical fast transient/burst according to EN 61000-4-4:1995 (AC/

 

DC power supply: ±1 kV, Data/Signal lines: ±0.5 kV)

 

• Surge immunity test according to EN 61000-4-5:1995

 

(AC/DC Line to Line: ±1 kV, AC/DC Line to Earth: ±2 kV)

 

• Immunity to conducted disturbances, Induced by radio-frequency

 

fields: EN 61000-4-6:1996 (0.15 - 80 MHz with

 

1 kHz AM 80% Modulation: 3 V/m)

 

• Power frequency magnetic field immunity test according to

 

EN 61000-4-8:1993 (1 A/m at frequency 50 Hz)

 

• Voltage dips, short interruptions and voltage variations immunity test

 

according to EN 61000-4-11:1994 (>95% Reduction @10 ms, 30%

 

Reduction @500 ms, >95% Reduction @5000 ms)

LVD:

• EN 60950-1:2001

Warning: Do not plug a phone jack connector in the RJ-45 port. This may damage this device.

iv

Image 4
Contents LevelOne Page Compliances FCC Class aCE Mark Declaration of Conformance for EMI and Safety EEC Power Cord Safety Safety ComplianceWarnhinweis Faseroptikanschlüsse Optische Sicherheit Power Cord Set Environmental Statement End of Product Life SpanManufacturing Materials DocumentationAudience PurposeRelated Publications Table of Contents Configuring the Switch Making Network ConnectionsGlossary Index Xii Tables XiiiFigures 26 Igmp Snooping Configuration -37 -27 Igmp Snoop Status Xvi Chapter OverviewSwitch Architecture Network Management OptionsPort and Power Status LEDs Description of Hardware10/100/1000BASE-T Ports SFP SlotsPort SFP Web Smart Switch Power Supply Socket Features and BenefitsConnectivity Performance ExpandabilityManagement Introduction to Switching Chapter Network PlanningApplication Examples Collapsed BackboneCentral Wiring Closet Central Wiring ClosetRemote Connections with Fiber Cable Remote Connections with Fiber CableMaking Vlan Connections Making Vlan ConnectionsApplication Notes Installing the Switch Selecting a SiteEthernet Cabling RJ-45 ConnectionsEquipment Checklist Package ContentsMounting Optional Rack-Mounting EquipmentInstalling the Switch Attaching the Brackets Desktop or Shelf Mounting Attaching the Adhesive FeetInstalling an SFP Transceiver Inserting an SFP Transceiver into a SlotConnecting to a Power Source Power SocketConnecting Network Devices Chapter Making Network ConnectionsTwisted-Pair Devices Cabling GuidelinesConnecting to PCs, Servers, Hubs and Switches Making Twisted-Pair ConnectionsNetwork Wiring Connections Wiring Closet ConnectionsFiber Optic SFP Devices Making Connections to SFP Transceivers Connectivity Rules 1000BASE-T Cable RequirementsMbps Gigabit Ethernet Collision Domain Maximum 1000BASE-T Gigabit Ethernet Cable LengthMbps Fast Ethernet Collision Domain Mbps Ethernet Collision DomainCable Labeling and Connection Records Configuring the Switch Using the Web InterfaceNavigating the Web Browser Interface HomeWeb Page Configuration Buttons Configuration OptionsPanel Display Switch Main Menu Main MenuQOS Web Configuration Displaying Status OverviewTrunk Information Switch Information Showing Port Statistics Port StatisticsPort Statistics Parameter DescriptionThis Ethernet segment Bytes Frames Total number of frames including bad packets Displaying System Name Setting the Switch’s IP Address System NameConfiguring the Logon Password Field AttributesReset to Factory Defaults ToolsReset to Factory Defaults Upgrade Firmware Upload/Download Configuration 10 Restart Switch Set boot ImageRestart Switch Static MAC Address ConfigurationStatic MAC Add Static MACCounter Config 13 Static MAC Address ConfigurationPort Configuration 14 Counter Configuration15 Port Configuration Storm Control Port Mirroring 16 Port Broadcast ControlCable Diagnostic 17 Port Mirroring18 Cable Diagnostics Trunks MembershipTrunk Configuration 19 Trunk MembershipVlan Settings Introduction to VLANsField Attributes Configuring the Switch 21 Vlan Settings Vlan Memembership 22 802.1Q Vlan Configuration QoS Disabled QOS Settings802.1p 24 QoS Settings Security25 Management Access Filter Configuration Settings Field Attributes Igmp Snoop26 Igmp Snooping Configuration Igmp Status 27 Igmp Snoop Status Diagnosing Switch Indicators Appendix a TroubleshootingTable A-1 Troubleshooting Chart Installation Power and Cooling ProblemsIn-Band Access Reset the Switch Troubleshooting Appendix B Cables Twisted-Pair Cable and Pin Assignments10BASE-T/100BASE-TX Pin Assignments Table B-1 10/100BASE-TX MDI and MDI-X Port PinoutsStraight-Through Wiring Figure B-2 Straight-through WiringCrossover Wiring Figure B-3 Crossover Wiring1000BASE-T Pin Assignments Cable Testing for Existing Category 5 CableTable B-2 1000BASE-T MDI and MDI-X Port Pinouts Adjusting Existing Category 5 Cabling to Run 1000BASE-T Fiber StandardsAppendix C Specifications Physical CharacteristicsSwitch Features Management FeaturesStandards CompliancesSoftware Loading CE Mark EmissionsSpecifications 1000BASE-T GlossaryAuto-Negotiation Bandwidth CollisionCollision Domain End StationFull Duplex Gigabit EthernetIeee Ieee 802.3abMedia Access Control MAC LayerLink Segment Local Area Network LANRedundant Power Supply RPS RJ-45 ConnectorSwitched Ports Transmission Control Protocol/Internet Protocol TCP/IPGlossary-6 Index NumericsIndex-2 Index-3 Index-4 Page GSW-2476 E082006-JC-R01 149100011100H