Datasheet

Specifications

This section lists basic platform specifications. For further details, refer to the hardware installation manuals on www.juniper.net/techpubs/hardware/.

Specification

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M7i

M10i

M20

M40e

M320

 

 

 

 

 

 

 

Physical

Dimensions

3.5 x 17.5 x 18 in

8.75 x 17.5 x 18 in

14 x 17.4 x 21 in

35 x 17.4 x 26 in

34.8 x 17.4 x 25.7 in

 

(H x W x D)

8.9 x 44.5 x 45.7 cm

22.2 x 44.5 x 45.7 cm

35.6 x 44.3 x 53.3 cm

88.9 x 44.3 x 73.7 cm

88.4 x 44.3 x 65.1 cm

 

 

 

 

 

 

 

 

Maximum Weight

38.2 lbs / 17.3 Kg

79 lbs / 36 Kg

150 lbs / 68 kg

370.5 lbs / 168 kg

439 / 199.6 kg

 

 

 

 

 

 

 

 

Mounting

Front or center

Front or center

Front or center

Front or center

Front or center

 

 

 

 

 

 

 

DC System Input

 

10 A at –48 VDC

12 A at –48 VDC

24 A at -48 VDC

54 A at -48 VDC

65 A at -48 VDC

Power (Fully

 

378 watts

576 watts

1,200 watts

2,600 watts

3,150 watts

Loaded)

 

 

 

 

 

 

 

 

 

 

 

 

 

DC Input Power

Nominal Voltage

-48, -60 VDC

-48, -60 VDC

-48, -60 VDC

-48, -60 VDC

-48, -60 VDC

Supply (per

 

 

 

 

 

 

individual power

 

 

 

 

 

 

supply)

Operating Range

-42 to -72 VDC

-42 to -72 VDC

-42 to -72 VDC

-42 to -72 VDC

-42 to -72 VDC

 

 

 

 

 

 

 

 

Power

378 watts

576 watts

1,200 watts

3,150 watts

2,000 watts

 

 

 

 

 

 

 

 

Current Rating

10 A at –48 VDC

12 A at –48 VDC

24 A at -48 VDC

65 A at -48 VDC*

42A at -48 VDC

 

 

 

 

 

 

 

 

# of power supplies required (non-

1/2

2/4

1/2

1/2

2/4

 

redundant/ redundant)

 

 

 

 

 

 

 

 

 

 

 

 

AC System Input

 

4 to 2 A

8 to 4 A

12 to 6 A

15 to 13 A

17 A to 14 A

Power (Fully

 

100 to 240 VAC

100 to 240 VAC

200 to 240 VAC

200 to 240 VAC

200 to 240 VAC

Loaded)

 

47 to 63 Hz

47 to 63 Hz

47 to 63 Hz

47 to 63 Hz

47-63 Hz

 

 

400 watts

800 watts

1,950 watts

3,000 watts

3,500 watts

 

 

 

 

 

 

 

AC Input Power

 

100, 120, 200, 208,

100, 120, 200, 208,

100, 120, 200, 208,

200, 208, 220,

200, 208, 220, 240 VAC

Supply (per

 

220, 240 VAC

220, 240 VAC

220, 240 VAC

240 VAC

 

individual power

 

 

 

 

 

 

supply)

 

 

 

 

 

 

Operating Range

90 to 264 VAC

90 to 264 VAC

90 to 264 VAC

180 to 264 VAC

180 to 264 VAC

 

 

 

 

 

 

 

 

 

Power

400 watts

800 watts

1,200 watts

3,000 watts

1,750 watts

 

 

 

 

 

 

 

 

Current Rating

4 to 2 A

8 to 4 A

12 to 6 A

16 A

10 to 8.5 A

 

 

100 to 240 VAC

100 to 240 VAC

100 to 240 VAC

200 to 240 VAC

200 to 240 VAC

 

 

 

 

 

 

 

 

# of power supplies required (non-

1/2

2/3

1/2

1/2

3/4

 

redundant/ redundant)

 

 

 

 

 

 

 

 

 

 

 

 

* The M40e router does not require circuit breakers greater than 60 A, and does not draw greater input current than 54 A.

 

 

* The depth of all chassis are measured from the front flange to the rear of the product. Please add 4-6" for cables and airflow clearance.

 

 

 

 

 

 

 

 

Image 5
Contents Access Agnostic with Leading Density Consistent Services to All CustomersSeries Routing Platforms Enhanced for the EdgeRich Packet Processing Features BenefitsHighly Reliable Robust SecuritySeries Routers MplsVPN Key Components M20 RouterDescription SpecificationsFPC Compact Forwarding Engine Board System and Switch BoardMB Ssram Miscellaneous Control Subsystem Control Board GB DramOrdering Information