ICP DAS USA I-7540D user manual ¾ Example

Page 80

¾Example:

Command: 99$P1140400000000FFFFFFFF00

Response: OK

Set the setting of CAN specification=2.0A, CAN baud rate= 125 Kbps, acceptance code=00000000, acceptance mask=FFFFFFFF, disable error response, disable timestamp response into the i-7540D and the 7540D response “OK” command to mean that the configuration of CAN has been changed.

Note: This command can only be accepted by 7540D’s port 10000

i-7540D CAN-Ethernet Gateway User’s Manual (Version 1.4, April/2008)

80

Image 80
Contents I-7540D CAN-Ethernet Gateway Table of Contents 106 Introduction Features Specifications 7540D Software Utility tool ApplicationVxComm Technology Page Block Diagram HardwarePin Assignment Pin assignment on the i-7540D1 RS-232 & RS-485 & Power supply Interface Pin Name DescriptionPin No Signal Description Connect to can BusEthernet Connect RX+Terminator resistor settings XC100 I/O expansion board Layout J3 Jumper Selection Power LED LED IndicationCan bus indicator LED Condition DescriptionCondition Description 3 5-digits 7-Segment LED Displays Page Page VxComm Utility 7540D UtilityMiniOS7 Utility I-7540D Utility I-7540D UtilityInstall i-7540D Utility Install & uninstall the i-7540D UtilityReady to Install the Program dialog You can find i-7540D Utility at the Start in the task bar Uninstall i-7540D Utility 10 Modify, repair, or remove the program dialog 12 Maintenance Complete dialog How to configure the module parameters 13 i-7540D’s IP settingPage Page RS-232/RS485 IP/Gateway/Mask Web ID/Password Can Pair Status How to set the Bus Timing Registers How to set the Acceptance Code and Mask RTRPage Enable Error Response Enable Time-stamp Response How to change web ID/PASSWORD configuration Page How to test the module transmission performance 18 Send and receive can messages 19 Timer mode to send can message How to use can Bus Pair Connection Can Pair StatusApplication 01 one-to-one communication Application 02 one-to-many communication broadcast Page Maintenance ConfigureMiniOS7 Utility Supported connection waysInstall the MiniOS7 Utility PC Diagnostic tools Page Page Page Page VxComm Utility Support Command List Port 10003 Command Format CommandCRPort 10000 Command Format 99Command #PWPWTIIILDD…CR ¾ Syntax tIIILDD…CR Represent a standard 2.0A data frame¾ Response ¾ NoteTiiilcr ¾ Syntax TiiilcrEIIIIIIIILDD…CR Eiiiiiiiilcr ¾ Syntax Eiiiiiiiilcr¾ Syntax 99S Command character ¾ Response 99SCan status register list AsciiToHexFF Name Value Function ¾ Syntax 99C ¾ Example Command 99C99C ¾ Syntax 99RA ¾ Example Command 99RA99RA 99#P01 ¾ Syntax 99#P01¾ Example 99#P02 ¾ Syntax 99#P02¾ Example 10 99#P1 ¾ Syntax 99#P1¾ Example Command 99#P1 11 99#P1B ¾ Example 12 99$P0105BBDSP ¾ Syntax 99$P0105BBDSP¾ Example 13 99$P0205BBDSP ¾ Syntax 99$P0205BBDSP¾ Example 14 99$P114PBCC…MM…ET ¾ Syntax 99$P114PBCCCCCCCCMMMMMMMMET¾ Example 15 99$P1B04TTRR ¾ Syntax 99$P1B04TTRR16 99#PWID ¾ Syntax 99#PWID17 99#PWPW 18 99$PWIDLLxxxxx… ¾ Syntax 99$PWIDLLxxxxx…19 99$PWPWLLxxxxx… ¾ Syntax 99$PWPWLLxxxxx…Supported by the firmware v1.06 or later 20 99#PPC¾ Syntax 99#PPC 21 99#PPIP ¾ Syntax 99#PPIP22 99$PPCLLABC ¾ Syntax 99$PPCLLABC23 99$PPIPxxx… ¾ Syntax 99$PPIPxxx…General Error codes for commands from port VxComm Applications OverviewArchitecture Ports mapping Installing the VxComm Driver Driverpc 8000cd\\Napdos\7188e\TCP\vxcomm\driverpc\Page Adding an i-7540D and configuring the VxComm Driver Timeout ms field Command Port fieldCheck Duplicated IP option Connect to Server optionUse 7188E/8000E current setting Fixed Configuration Re-assign COM number for all subsequent ports optionKeep Alive Time ms field Connection-Broken ms fieldPort7000 Port field Connect Timeout ms fieldCommand TCP Port field Page Removing an i-7540D Click the Exit button to finish this utility Uninstalling the VxComm Driver Page Hardware SoftwareI-7540D Utility tool T12381122334455667788 Diagnostics and Troubleshooting DiagnosticsPage Page „ Example 2 Close-Loop Testing Page „ Example 3 External-Devices Testing Series module 7520 MaleMalePage Trouble Shooting Page Page Page Error Code Only For i-7540D’s COM3 can port
Related manuals
Manual 8 pages 56.44 Kb

I-7540D specifications

The ICP DAS USA I-7540D is an advanced industrial field gateway designed to provide seamless communication between remote I/O devices and various industrial protocols. This device plays a crucial role in modern automation systems, enabling data acquisition and control over diverse industrial environments.

One of the key features of the I-7540D is its support for multiple communication protocols, including Modbus TCP/IP and MQTT. This versatility allows users to integrate the device into various industrial networks easily, facilitating connectivity with PLCs, SCADA systems, and various IoT applications. As a result, the I-7540D significantly enhances interoperability among devices, regardless of the manufacturer or communication protocol.

The I-7540D also boasts robust hardware specifications that ensure reliable performance in demanding industrial environments. With a wide operating temperature range from -25°C to 75°C, this gateway is equipped to withstand extreme temperatures, making it suitable for outdoor and harsh indoor applications. Additionally, it features a durable design that meets various industrial standards, ensuring long-term operation without frequent maintenance.

In terms of user accessibility, the I-7540D includes comprehensive web-based configuration and monitoring tools. This user-friendly interface simplifies the setup process, enabling users to manage their devices remotely without needing specialized software. Enhanced security features, including HTTPS and user authentication, protect data integrity and ensure that only authorized personnel can access the system.

The integration of wireless communication capabilities in the I-7540D sets it apart from traditional wired gateways. This feature opens up new possibilities for industrial applications, such as connecting devices in hard-to-reach locations or areas where cabling is impractical. The device supports various wireless standards, including Wi-Fi and cellular networks, allowing for flexible installation and minimal infrastructure costs.

In summary, the ICP DAS USA I-7540D is a feature-rich industrial field gateway that excels in facilitating communication across diverse devices and protocols. With its flexibility, robust design, and user-friendly interface, it serves as an essential tool for industries aiming to harness the power of automation and IoT technologies. By incorporating the I-7540D into their systems, organizations can significantly enhance operational efficiency, improve data collection, and streamline processes, paving the way for a more connected and intelligent industrial environment.