GE DEH-230 manual Installing and configuring remote HMI software

Page 25

7 Installing and configuring remote HMI software

Entellisys Remote HMI software allows users to access the switchgear system from any desktop computer.

There are two versions of Remote HMI software:

User Interactive version: provides programmable permission levels for all users from full “Administrator” access to view-only “Guest” privileges.

Viewer version: limited to view-only “Guest” privileges. Login name and passwords are fixed.

The following steps are required to install and configure the Entellisys Low Voltage Switchgear –

 

 

Remote HMI software:

7

 

 

 

Step 1: Review computer requirements

 

 

Please verify the target computer meets the requirements before proceeding:

 

 

 

 

 

OS

Microsoft Windows 2000, Service Pack 3, required

 

 

 

 

 

Processor

Pentium III 1 GHz and 133 MHz processor bus, minimum

 

 

 

 

 

Memory

256 MB RAM, minimum

 

 

 

 

 

Storage device

Hard disk drive 20 GB, minimum

 

 

 

 

 

Screen resolution

1024x768 in 256 colors, preferred

 

 

 

 

 

USB port

One port required (USB 1.0 or 2.0)

 

 

 

 

 

Step 2: Install and launch the HMI program

Insert the “Entellisys Remote HMI” CD and run the install program. Follow the onscreen installation wizard. Click Finish to complete the installation.

To start the Entellisys Remote HMI application, point to Start, select Programs, and then double-click Entellisys LVS HMI.

Step 3: Activate the software with a code from GE

The first time the Remote HMI program is launched, a window will display requesting an

Activation code.

25

Image 25
Contents System Administrator Manual DEH-230 How to contact us Page Contents Administrator access to the operating system System Maintenance System administrator roles ResponsibilitiesSecurity Champion System administrator roles and responsibilities Pre-programming settings prior to switchgear arrival Pre-programming settings prior to switchgear arrival Commissioning the switchgear Commissioning the switchgear HMI permissions and passwords PasswordsSetting HMI login permissions and passwords Names and passwords To change a password Resetting forgotten HMI passwordsModbus security Control and settings passwordsLocal HMI Breaker Control screen Time synchronization Setting time in the HMITime synchronization CPU a CPU B Configuring the switchgear for remote communicationsHMI IP address Setting IP addresses for remote communicationCPU IP address Set CPU IP Addresses screen Network security/VPN device Installing and configuring remote HMI software Site Code See HMI IP address on Installing and configuring remote HMI software Offline mode Settings files and offline system configurationTo enable or disable offline mode Viewing and comparing settings files Settings file compare screen Write Settings screen Writing settings to a live systemResetting the offline settings files to the current settings Publishing shared files Sharing files across HMIsUpdating an HMI with shared files Archive screen System archivesCreating an archive Restoring an archiveArchive File Selection screen System archives Viewing installed options Feature optionsUpgrading options Upgrade Options screenUpgrading options Feature options Part I Preparation for replacement of a CPU Preparing and configuring a replacementAfter clicking Next, the following instructions will display CPU Serial Number dialog box Option String dialog box Part II Replacing the CPUPart II Replacing the CPU Set Default IP dialog box 10 Set Original IP dialog box 12 CPU Firmware dialog box 14 Copy Setting dialog box Preparing and configuring a replacement CPU Viewing and updating circuit breaker names Other maintenance functionsViewing and updating circuit breaker accessories Breaker Accessories screen CPU Firmware Download screen Installing CPU firmwareViewing zone configuration Other maintenance functions Administrator access to the operating system

DEH-230 specifications

The GE DEH-230 is an advanced digital electro-hydraulic control system designed for industrial applications, particularly in power generation and processing sectors. This innovative system is a product of General Electric, a company renowned for its cutting-edge technology and engineering solutions. The DEH-230 is specifically engineered for steam turbines, gas turbines, and hydro turbines, providing exceptional control and reliability.

One of the standout features of the DEH-230 is its modular architecture. This design allows for flexibility and scalability, making it suitable for a wide range of applications. The system can be easily integrated into existing setups, accommodating different sizes and types of turbine controls. This modular approach also simplifies maintenance and upgrades, ensuring that facilities can adapt to changing operational needs.

In terms of technology, the GE DEH-230 employs highly sophisticated algorithms for precise control of turbine operations. The system utilizes advanced signal processing techniques and real-time data analytics to optimize performance. This capability helps in enhancing efficiency and reducing emissions, aligning with the global push for more sustainable energy solutions.

The DEH-230 also features robust communication protocols that facilitate seamless integration with various industrial control systems. This interoperability ensures that operators can achieve optimal control and monitoring of turbine operations within a centralized platform. The system is equipped with graphical user interfaces that enhance the user experience, making it easier for operators to adjust parameters and respond swiftly to operational demands.

Another important characteristic of the DEH-230 is its reliability. Built with high-quality components, the system is designed to withstand harsh operational environments, ensuring minimal downtime and consistent performance. With redundant systems and fail-safe mechanisms in place, it provides an added layer of security, which is critical in power generation applications.

Finally, the GE DEH-230 is backed by GE’s extensive support and service network. This ensures that users have access to expert assistance and resources whenever needed, contributing to the overall value proposition of the system. By combining advanced technology with dependable service, the DEH-230 stands out as a leading solution for modern turbine control needs.