GE GFK-1852 user manual Connect Mode, Automatic Connection Address

Page 34

4

Connect Mode

This parameter defines how the VMSE makes a connection and how it reacts to incoming connections over the network.

Function

7

6

5

4

3

2

1

0

Connection Acceptance

 

 

 

 

 

 

 

 

-never accept incoming

0

0

0

 

 

 

 

 

-accept incoming with active DTR only

0

1

0

 

 

 

 

 

-accept unconditional (if not busy)

1

1

0

 

 

 

 

 

Response on Serial to Connect

 

 

 

 

 

 

 

 

-nothing (quiet)

 

 

 

0

 

 

 

 

-character response: (C=conn., D=disc.,

 

 

 

1

 

 

 

 

N=not available/unreachable)

 

 

 

 

 

 

 

 

Active Connection Startup

 

 

 

 

 

 

 

 

-no active connection startup

 

 

 

 

0

0

0

0

-start connection with any character on

 

 

 

 

0

0

0

1

the serial line

 

 

 

 

 

 

 

 

-start connection with active-going

 

 

 

 

0

0

1

0

DTR line

 

 

 

 

 

 

 

 

-start connection with CR (0x0d) only

 

 

 

 

0

0

1

1

-manual connection startup

 

 

 

 

0

1

0

0

(‘C’ + address)

 

 

 

 

 

 

 

 

Datagram Mode

 

 

 

 

1

1

0

0

Modem Emulation Mode

 

 

 

 

0

1

1

0

Figure 4-4. Connect Mode Options

Please refer to Appendix B for information on converting values to hexadecimal format.

Automatic Connection Address

Using either of the serial ports, an automatic TCP connection to a network node can be configured by setting the remote IP address and the TCP port number parameters.

If automatic connection is selected, all parameters must be supplied in full.

If manual connection startup is configured (with “C” + address/port), only the part not supplied in the command string is used. In manual mode, the last byte of the address must be supplied.

4-12

VersaMax Serial to Ethernet Adapter User's Manual – July 2000

GFK-1852

Image 34
Contents GE Fanuc Automation GFL-002 Preface Contents Contents Chapter Serial Line Interfaces Appendix a IP Addresses Introduction and Quick Start IntroductionPass Thru Firmware Vmse Firmware OptionsSRTP/SNP Firmware Modbus TCP/RTU firmwareQuick Start Default IP AddressProcedure Assigning a New IP Address Preliminary StepResults of the Ping Command Results of the Telnet 3.16.27.44 1 Command Screen Appearance Just Before Step G Vmse Configuration Screen GFK-1852 Configuration Command PromptConfiguration Example Parameter PromptIntroduction and Quick Start Vmse Interfaces Serial InterfaceNetwork Interface Power RequirementsHardware Address MAC Address Packing Algorithm PassThru Firmware only Network ProtocolsIP Address Port Number Configuration Steps ConfigurationEntering Serial Configuration Mode Entering Network Configuration Mode VMSE’s IP AddressArp -s 191.12.3.77 00-20-4A-01-64-0B Assigning a New IP AddressUnix Telnet 191.12.3.77Configuration Parameters SRTP/SNP Firmware Configuration Setup Network/IP SettingsGateway IP Address Channel, Serial, and Protocol SetupsSRTP/SNP Protocol Mode NetmaskSNP ID to IP Address Mapping only for SRTP/SNP Mode#2 Serial Interface ConfigurationSNP T1 T4 Timers SNP ID a IP AddressPassThru Firmware Configuration Setup Basic ParametersGateway IP Address Telnet Configuration PasswordIP Address NetmaskCommon settings Interface ModeFlow Control Remote IP Address Port NumberRemote TCP Port Connect Mode Automatic Connection AddressATDTx.x.x.x,pppp or ATDTx.x.x.x/pppp Datagram ModeModem Emulation Mode ATDTx.x.x.xATD0.0.0.0 Disconnect ModeForce Telnet Mode ATDx.x.x.xBuffer Flushing Inactivity TimeoutPack Control Send Characters Telnet Terminal TypeModbus TCP/RTU Firmware Configuration Setup Modbus Hardware Configuration ScreenProtocol Serial and Mode SettingsModem Control Settings Serial InterfaceAdvanced Modbus Protocol Settings Modbus ID to IP Address Mapping only used for MasterMonitor Commands Monitor Mode and Firmware UpgradeCommand Description SI194.39.78.234146.138.146.138 Command result codesFirmware Download Using Serial Port IP address =HyperTerminal Dialog Box Firmware Download Using a Network Host Windows NT Procedure Firmware DistributionDestination Password Windows NT Command Line Example Code ExplanationVmse Firmware File List Windows 95/98 Procedure Obtaining Tftp Software for Windows 95/98Serial Line Interfaces Serial Line InterfacesScrew Block Connector Pin-outs and Other Components Front Panel LayoutFront Panel Components Cable Diagrams Cable IC200CBL504 To PLCUser-Built Cable #1 Vmse RJ45 Serial to Miniconverter SpecificationsApplication User-Built Cable #2 Vmse RJ45 Serial to PC 9-Pin Sub-D For Serial Monitor/Load of VmseUser-Built Cable #3 Vmse RJ45 Serial to PC 9-pin D-Sub 10. Vmse to VersaMax Serial CableUser-Built Cable #4 Vmse RS-422 Terminals to PLC To PLC RS-422/485 Serial PortUsing the Vmse on an RS-422/485 Multidrop Network Multidrop Application NotesPin No Signal Description 15. IBM-AT 9-Pin Serial Port ConnectorPin, D-Sub PLC Serial Port Connector 3LQ15-Pin, D-Sub PLC Serial Port Connector RS-485 Port 15-Pin Female D-SubPin Signal Name Description Number RJ-11 PLC Serial Port ConnectorRS-232, 6-Pin RJ-11 RJ-45 VersaMax Nano/Micro PLC Serial Port Connector RS-232, 8-Pin RJ-45IC690ACC901 Miniconverter 9-Pin, Male D-Sub Connector 20. IC690ACC901 Miniconverter RS-232 Connector Pin-OutTechnical Data LEDs DimensionsWeight CaseClass a Network IP AddressesIP Addressing Class B NetworkBroadcast Address Class C NetworkNetwork Address IP NetmaskPrivate IP Networks and the Internet Network RFC’s Binary to Hexadecimal Conversion Table Decimal Binary HexadecimalElectromagnetic Emissions Product SafetyDeclaration of Conformity Electromagnetic ImmunityIndex Index LEDSRTP/SNP

GFK-1852 specifications

The GE GFK-1852 is an advanced communication and control processor designed for industrial automation solutions. It serves as a critical component in the realm of programmable logic controllers (PLCs) and offers robust features that enhance operational efficiency across various sectors.

One of the standout features of the GE GFK-1852 is its support for multiple communication protocols. This flexibility allows it to connect seamlessly with various devices and systems, making it an excellent choice for complex industrial environments. The GFK-1852 is compatible with Ethernet/IP, Modbus TCP/IP, and other industrial communication standards, facilitating integration with a wide range of equipment and network configurations.

Another significant aspect of the GE GFK-1852 is its high processing speed and performance. Equipped with a powerful processor, it can handle extensive data processing needs, ensuring real-time response and minimal latency. The device supports multiple I/O configuration options, which can be tailored to meet the specific requirements of a given application. This adaptability makes it suitable for both small-scale and large-scale operations.

The inclusion of built-in security features is also noteworthy. The GE GFK-1852 comes with various encryption protocols and user authentication mechanisms to safeguard against unauthorized access and cyber threats. This aspect is increasingly important in today’s interconnected industrial landscape where security vulnerabilities can lead to significant operational disruptions.

Additionally, the GE GFK-1852 offers sophisticated diagnostic and monitoring capabilities. Users can gain valuable insights into operational performance through real-time data analytics and logging features. This empowers maintenance teams to address potential issues proactively, ultimately improving uptime and reducing maintenance costs.

Another key characteristic is its user-friendly interface. The GFK-1852 is designed with ease of use in mind, enabling operators to configure and manage the device with minimal training. Programmed through intuitive software tools, it simplifies complex tasks and enhances user productivity.

In conclusion, the GE GFK-1852 stands out as a versatile and high-performance communication processor ideal for diverse industrial applications. Its support for multiple communication protocols, high-speed processing, built-in security, and user-friendly design make it a top choice for businesses looking to optimize their automation systems. By leveraging the capabilities of the GFK-1852, organizations can seamlessly integrate their operations, enhance productivity, and ensure a secure industrial environment.