RS-232 SERIAL CONTROL INTERFACE

What features are available via the RS-232 serial communications port?

The TV Multi Format Switcher can accept commands through the RS-232 serial communications port located on the rear panel. The current RS-232 control commands allow switching/routing of A/V inputs to outputs without the use of the IR remote control.

How do I use these features?

These features were initially intended for utilization by custom installers in automated setups. However, these features can be tested by using any computer equipped with a 9-pin serial port and a terminal emulation program.

What pins are used to communicate with the TV Multi Function Switcher?

Only pins 2 (Receive), 3 (Transmit), and 5 (Ground) are used for communication. A straight-through cable should be used with this Switcher.

5 4 3 2 1

1 2 3 4 5

9 8 7 6

6 7 8 9

Only Pins 2 (RX), 3 (TX), and 5 (Ground) are used on the RS-232 serial interface

What are the RS-232 communications port settings?

 

Bits per second

9600

Data bits

8

Parity

None

Stop bits

1

Flow Control

None

10

Image 13
Contents Multi-Format Switcher Write To Asking for AssistanceContents Gefen IntroductionOperation Notes Package Includes FeaturesPanel Layout Front Panel Panel DescriptionsConnecting and Operating the EXT-TV-MFS CV1 CV2 SV1 SV2 CO1 CO2 PC HD1 HD2 HD3 Multi Format Switcher Remote DescriptionEXT-TV-MFS Remote Installation Extending the IR Range IR Code ConfigurationRS-232 Serial Control Interface How do I use these features?Commands RS-232 Serial Communication CommandsSpecifications Page Rev A8 Nordhoff St., Chatsworth CA