Gefen EXT-HDMI1.3-244 External Edid Management, Following Edid features are copied from Output

Page 15

EDID MANAGEMENT

External EDID Management

The 2x4 Switcher for HDMI 1.3 features EDID Management. Before the source can send video or audio signals, the source device reads the EDID (Extended Display Identification Data) from the output devices connected to the Splitter. The EDID contains information about what type of A/V data that the source can send to each output device.

The 2x4 Switcher for HDMI 1.3 distributes a single source to multiple output devices. This involves reading EDID data from more than one device. Management of the EDID data is important to maintain compatibility between all devices.

The following EDID features are copied from Output 1:

Supported Resolutions

3D Support

Audio Features

EDID color features are built based on all attached displays, using the following rules:

Deep Color will be enabled if one or more displays are connected to the Splitter supporting Deep Color.

xvYCC (x.v.Color) is supported if all connected displays support it.

Display Connections:

If a display is not connected to Output 1, then no EDID changes are made, meaning that the previous EDID information will be used. This state will be in effect until a display is connected to Output 1 and the Splitter is power- cycled.

EDID is built from Output 1 to the Input. The audio block will be copied from Output 1. EDID-copying is performed only when the Splitter is reset or power-cycled.

12

Image 15
Contents 2x4 Switcher for Hdmi Write To Asking for AssistanceTechnical Support Technical Support HoursContents How It Works Gefen 2x4 Switcher for HdmiIntroduction GefenOperation Notes Features Hdmi FeaturesFeatures Panel Layout Panel Descriptions Power LED IndicatorWiring Diagram for the Gefen 2x4 Switcher for Hdmi Connecting and Operating 2X4 Switcher for HdmiHow to Connect the 2x4 Switcher for Hdmi How to Operate the 2x4 Switcher for HdmiIR Remote Description RMT-2IR Remote Control UnitInstalling the IR Remote Control Battery IR Remote InstallationSetting the IR Remote Channel on the RMT-8IR IR Remote ConfigurationSetting The IR Channel IR Channel ConfigurationAudio Format Supported Channels Edid Mode SelectionEdid Management Timing Refresh RateFollowing Edid features are copied from Output External Edid ManagementDisplay Connections 5V DC SpecificationsProduct Registration WarrantyRev B3 Nordhoff St., Chatsworth CA