FTLF1217P2xTL Pluggable SFP Product Specification – September 2008
I.Pin Descriptions
Pin | Symbol | Name/Description | Ref. |
1 | VEET | Transmitter Ground (Common with Receiver Ground) | 1 |
2 | TFAULT | Transmitter Fault. | 2 |
3 | TDIS | Transmitter Disable. LED output disabled on high or open. | 3 |
4 | MOD_DEF(2) | Module Definition 2. Data line for Serial ID. | 4 |
5 | MOD_DEF(1) | Module Definition 1. Clock line for Serial ID. | 4 |
6 | MOD_DEF(0) | Module Definition 0. Grounded within the module. | 4 |
7 | Rate Select | No connection required |
|
8 | LOS | Loss of Signal indication. Logic 0 indicates normal operation. | 5 |
9 | VEER | Receiver Ground (Common with Transmitter Ground) | 1 |
10 | VEER | Receiver Ground (Common with Transmitter Ground) | 1 |
11 | VEER | Receiver Ground (Common with Transmitter Ground) | 1 |
12 | RD- | Receiver Inverted DATA out. AC Coupled |
|
13 | RD+ | Receiver |
|
14 | VEER | Receiver Ground (Common with Transmitter Ground) | 1 |
15 | VCCR | Receiver Power Supply |
|
16 | VCCT | Transmitter Power Supply |
|
17 | VEET | Transmitter Ground (Common with Receiver Ground) | 1 |
18 | TD+ | Transmitter |
|
19 | TD- | Transmitter Inverted DATA in. AC Coupled. |
|
20 | VEET | Transmitter Ground (Common with Receiver Ground) | 1 |
Notes:
1.Circuit ground is internally isolated from chassis ground.
2.TFAULT is an open collector/drain output, which should be pulled up with a 4.7k – 10k Ohms resistor on the host board. Pull up voltage should be between 2.0V to Vcc + 0.3V. A high output indicates an LED fault, i.e. LED open or short. Low indicates normal operation. In the low state, the output is pulled to <0.8V.
3.LED output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.
4.Should be pulled up with 4.7k – 10kohms on host board to a voltage between 2.0V and 3.6V. MOD_DEF(0) pulls line low to indicate module is plugged in.
5.LOS is open collector output. Should be pulled up with 4.7k – 10kohms on host board to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
♥ Finisar Corporation September 13, 2008 Rev. B | Page 2 |