How to Use This Guide

How to Use This Guide

This preface provides an overview of this guide and the DFE‐Gold Series manual set, and a brief summary of each chapter; defines the conventions used in this document; and instructs how to obtain technical support from Enterasys Networks.

To locate information about various subjects in this guide, refer to the following table:

For...

Refer to...

 

 

An overview of the DFE module

Chapter 1, Introduction

 

 

Network requirements that must be met before

Chapter 2, Network Requirements

installing the DFE module

 

 

 

Instructions to install the DFE module hardware

Chapter 3, Installation

 

 

Troubleshooting installation problems and

Chapter 4, Troubleshooting

diagnosing network/operational problems using the

 

LANVIEW LEDs in either the RX/TX port status

 

mode or PoE port status mode

 

 

 

Specifications, environmental requirements, and

Appendix A, Specifications

physical properties of the 4G4285-49 and

 

4G4205-72

 

 

 

Instructions to set the mode switches when

Appendix B, Mode Switch Settings and

necessary and remove and replace the DRAM

Option Installations

SIMM or DIMM memory

 

 

 

Overview of Power over Ethernet technology and

Appendix C, About PoE (Power over

how it is implemented in relation to the DFE

Ethernet)

modules.

 

 

 

Related Documents

The manuals listed below can be obtained from the World Wide Web in Adobe Acrobat Portable Document Format (PDF) at the following site:

http://www.enterasys.com/support/manuals

Enterasys Matrix DFE‐Gold Series Configuration Guide provides information on how to use the Command Line Interface to set up and manage the DFE modules.

Matrix N‐Series N‐POE Power System Installation Guide describes how to implement PoE and connect to the 48 Vdc Optional Power connector of the DFE module.

Cabling Guide provides information on dB loss and cable specifications.

Unlike the Enterasys Matrix DFE‐Gold Series Configuration Guide and the Matrix N‐ Series N‐POE Power System Installation Guide, the Cabling Guide is not listed alphabetically on the web site. Instead, it is listed under the Overview Guides link.

xvi About This Guide

Image 18
Contents Enterasys Matrix Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Supplement to Product Instructions Vcci Notice Safety Information Class 1 Laser Transceivers Enterasys NETWORKS, INC. Firmware License Agreement Viii Page Page Contents Troubleshooting Appendix a SpecificationsAppendix B Mode Switch Settings and Option Installations Appendix C About PoE Power over Ethernet IndexContents of DFE Module Carton TablesAbout This Guide Who Should Use This GuideImportant Notice How to Use This Guide Related DocumentsFor Refer to Conventions Used in This Guide Following conventions are used in this guideGetting Help Introduction For information about Refer toOverview of DFE-Gold Series PoE Module Capabilities DFE Modules 4G4285-494G4285-49 DFE-Gold Module 4G4205-72 4G4205-72 DFE-Gold Module Connectivity Switch Configuration Using WebViewNetwork Expansion Module NEM Option ManagementSwitch Configuration Using CLI Commands Secure Networks Policy SupportStandards Compatibility Lanview Diagnostic LEDs Lanview Diagnostic LEDs Introduction Network Requirements Module Placement in a Matrix E7 Chassis Link AggregationFTM Bridge Function and Optional NEM 10BASE-T Network 100BASE-TX Network1000BASE-T Network 1000BASE-T Network Network Requirements Installation Installation Site Requirement Contents of DFE Module Carton QuantityUnpacking the DFE Module Installing Optional Network Expansion Modules DFE Module Placement and Installation RulesExample 1 -1, a Example 2 -1, BInstalling the DFE Module into a Chassis Example 3 -1, CExample 4 -1, D Installing Module into Matrix E7 or N7 Chassis PreparationPreparing to Install Module into Matrix E7 or N7 Chassis Installing the DFE Modules into a Matrix E7 or N7 Chassis Preparing to Install Module into Matrix E7 or N7 Chassis DFE Preparing to Install Module into Matrix E7 or N7 Chassis Card guides Connecting 48 Vdc Power for PoE Operation Connecting to the Network Connecting UTP Cables to DFE ModulesConnecting a Twisted Pair Segment with RJ45 Connector Making the UTP ConnectionsConnecting to the Network RX+ TX+ TX1+ RX1 TX2+ TX3+ RX3 RX2 TX4+ RX4 Verifying PoE Port Status Connecting to COM Port for Local Management What Is NeededConnecting to an IBM PC or Compatible Device Parameter SettingConnecting to a VT Series Terminal 10 Connecting a VT Series TerminalConnecting to a Modem Adapter Wiring and Signal Assignments COM Port Adapter Wiring and Signal Diagram RJ45Modem Port Adapter Wiring and Signal Diagram RJ45 DB25Completing the Installation Completing the Installation of a New System12 Matrix DFE Startup Screen Example N7 Chassis Logging in with an Administratively-Configured User Account Troubleshooting Using LanviewAbout the Management Mgmt LED Viewing Receive/Transmit Activity on 4G4285-49 Lanview LEDs on 4G4285-49Viewing Receive/Transmit Activity on 4G4205-72 Lanview LEDs on 4G4205-72Viewing the PoE Port Status Lanview LEDsColor State Recommended Action RX/TX Indications in Standard Mode CPURX/TX LED Indications in PoE Port Status Mode RX/TXLED Troubleshooting Checklist Series Configuration Guide for properTroubleshooting Checklist Problem Possible Cause Recommended ActionOverview of DFE Module Shutdown Procedure Recommended Shutdown Procedure Using OFFLINE/RESET Switch OFFLINE/RESET SwitchLast Resort Shutdown Procedure Using OFFLINE/RESET Switch Specifications Processors/Memory DFE Module SpecificationsTable A-1 4G4285-49 Specifications PhysicalTable A-2 4G4205-72 Specifications Regulatory Compliance Table A-3 COM Port Pin Assignments Signal Name Input/OutputCOM Port Pinout Assignments Table A-4 Compliance Standards Regulatory ComplianceMode Switch Settings and Option Installations Required ToolsSetting the Mode Switches Memory Locations and Replacement Procedures Dram Simm Dimm Gaining Access to Memory Modules Removing the Safety CoverFigure B-3 Removing the Safety Cover Dram Simm Replacement Procedure Removing the Network Expansion Module NEMFigure B-4 Removing the Network Expansion Module NEM Installing the Dram Simm Removing the Dram SimmDimm Replacement Procedure Removing the DimmInstalling the Dimm Figure B-7 Removing the Existing DimmInstalling the Network Expansion Module NEM Figure B-8 Installing the DimmFigure B-9 Installing the Network Expansion Module Reinstalling the Safety Cover Figure B-10 Installing the Safety Cover Page About PoE Power over Ethernet OverviewProprietary PD Detection PoE Port Status LEDs Table C-2 PoE Status LED Indications PoE Port StatusOverview About PoE Power over Ethernet Index NumericsConnecting to 3-14Network expansion module

4G4205-72, 4G4285-49 specifications

Enterasys Networks is a distinguished name in the realm of networking solutions, offering a variety of high-performance switches and routers designed for enterprise environments. Among their impressive lineup, the 4G4285-49 and 4G4205-72 models stand out for their advanced capabilities and robust features that cater to the demanding needs of modern IT infrastructure.

The Enterasys 4G4285-49 is a high-density Layer 3 switch that provides exceptional performance and reliability. It is equipped to handle the increasing data traffic common in enterprise networks, facilitating enhanced throughput and reduced latency. This model features 48 Gigabit Ethernet ports, ideal for connecting a vast array of devices within a network, along with one or two 10 Gigabit SFP+ uplink ports, ensuring fast data transmission to other network segments.

On the other hand, the 4G4205-72 is specifically designed as a versatile access switch with 24 Gigabit Ethernet ports and an additional 4 SFP+ uplink ports. This configuration makes it perfect for connecting endpoints like computers, printers, and other network devices while also providing scalability for future expansion.

Both models leverage advanced technologies such as Virtual LAN (VLAN) support, which helps in segmenting network traffic for better performance and security. Quality of Service (QoS) features are integrated, allowing administrators to prioritize critical applications and ensure optimal performance during high traffic periods. Additionally, security protocols like Access Control Lists (ACLs) and port security measures safeguard the network against unauthorized access.

The Enterasys 4G4285-49 and 4G4205-72 also support advanced management capabilities. With intuitive web-based interfaces and support for SNMP (Simple Network Management Protocol), IT teams can efficiently monitor network performance and troubleshoot issues as they arise.

In terms of build quality, both models are designed for reliability, featuring robust chassis and components that withstand the rigors of a data center environment. Their energy-efficient designs also contribute to reduced operational costs, aligning with the growing demand for sustainable networking solutions.

In summary, Enterasys Networks' 4G4285-49 and 4G4205-72 models combine high performance, advanced networking technologies, and robust security features, making them ideal choices for enterprises looking to enhance their network infrastructure and manage increasing data demands effectively.