Dialogic VFX/41JCT-LS Complete Board Installation, Connect External Cables, Sales Assistance

Page 2

3.Insert the board’s edge connector into the bus slot. Use the slot’s board guides as you insert the board edge connector into the slot. Apply pressure only to the top edge of the board, and press firmly until the edge connector is securely seated in the slot.

2.Attach the cable to the next board until all boards are connected by the cable.

Colored Stripe (Pin 1)

Your CT Bus cable may have a different number of connectors (drops).

3. If the cable has extra connectors or is loose, tuck the

cable down so that it does not snag when you replace

the computer cover. See the Caution given earlier in

this section.

7. Complete Board Installation

After you have installed the board(s) and if applicable attached cables and adapter, replace the computer cover and re-attach power cords.

8. Connect External Cables

Each RJ-11 jack on the rear bracket of the voice board supports a single voice channel. Use each RJ- 11 jack and phone cable to connect each channel to an analog PBX or standard telephone outlet.

Since this board emulates a standard telephone, a standard telephone will not function when directly attached to the board.

Rear bracket

on board

Your application software or Dialogic software release may have special installation or configuration requirements. Be sure to read your software documentation including release note information before you install the software.

Note: If you are adding hardware to an existing system, you do not need to uninstall existing Dialogic® software.

10. Warranty and Return Information

Warranty Period

For specific warranty information for this board, refer to the Warranty section of the Products page, located at this URL: http://www.dialogic.com/warranties/.

Contacting Technical Support

All contents of this document are furnished for informational use only and are subject to change without notice and do not represent a commitment on the part of Dialogic Corporation or its subsidiaries (“Dialogic”).

Reasonable effort is made to ensure the accuracy of the information contained in the document. However, Dialogic does not warrant the accuracy of this information and cannot accept responsibility for errors, inaccuracies or omissions that may be contained in this document.

INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH DIALOGIC® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN A SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO LIABILITY WHATSOEVER, AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF DIALOGIC PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY.

Dialogic products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications.

4.Replace and tighten the retaining screw to secure the board. If the screw is not installed and you attach a CT Bus cable to the board, the board may be accidentally unseated from the slot.

5.To install an additional board, select an empty PCI slot adjacent to the location of the previous board, and repeat (the second part of) step 2 through step 4.

5.Attach CT Bus Cable to Board (optional)

Colored Stripe (Pin 1)

If you use the board in stand-alone mode, skip the instructions in this section.

Use a CT Bus cable to connect your board to other CT Bus form-factor boards in the system.

Caution! To preserve the electrical integrity of the CT Bus, use a CT Bus cable with the appropriate number of connectors (“drops”). We recommend that no more than two connectors at either end of the cable be left unused. In addition, it is preferable to distribute the

6. Connect CT Bus/SCbus Adapter (optional)

If you use the board in stand-alone mode, skip the instructions in this section.

To connect your board to SCbus form-factor boards, use the CT Bus/SCbus adapter (part number

882-757-xx). You may use only one CT Bus/SCbus adapter per system.

1.Before installing the adapter, the Dialogic® boards in your chassis must be positioned in the correct order. The board on which the adapter is installed must be inserted in the first PCI slot adjacent to an ISA slot. Locate this board.

2.Align pin 1 of the adapter with pin 1 of the edge connector on the board. Press the adapter onto the board with the SCbus cable connector facing the rear edge of the board.

CT Bus / SCbus

Adapter

CT Bus

SCbus

Cable

Cable

 

Colored Stripe

 

Channel 1

Channel 2

Channel 3

Channel 4

J1-J4 on the VFX/41JCT-LS Board RJ-11 Connector

12 345 6

To analog

PBX or standard telephone outlet

Pin

Signal

 

 

1

Unused

 

 

2

Station - Earth Recall

 

 

3

Station - Ring

 

 

4

Station - Tip

 

 

5

Unused

 

 

6

Unused

 

 

Dialogic provides technical support for its products through a network of value added distributors who are trained to answer technical questions on installing and configuring Dialogic® products. If you are unsure how to contact your support channel, please call Dialogic in the United States at 973-967-6600 (9am-5pm EST) and we will assist in obtaining the appropriate support channel. Outside the United States please refer to http://www.dialogic.com/support/contact to obtain local contact information.

Dialogic also provides direct support via Dialogic® Pro™ Services agreements. For more details of direct support from Dialogic please refer to: http://www.dialogic.com/support/DialogicPro.

Returning a Product

To return a board for warranty repair or any other returns, please refer to the following: http://www.dialogic.com/support/hwfaults. To return a board for warranty repair, please refer to the following: http://www.dialogic.com/support/hwfaults. For all other returns, contact your vendor or Dialogic Customer Support (for more information, see http://www.dialogic.com/support/contact/ ).

It is possible that the use or implementation of any one of the concepts, applications, or ideas described in this document, in marketing collateral produced by or on web pages maintained by Dialogic may infringe one or more patents or other intellectual property rights owned by third parties. Dialogic does not provide any intellectual property licenses with the sale of Dialogic products other than a license to use such product in accordance with intellectual property owned or validly licensed by Dialogic and no such licenses are provided except pursuant to a signed agreement with Dialogic. More detailed information about such intellectual property is available from Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9. Dialogic encourages all users of its products to procure all necessary intellectual property licenses required to implement any concepts or applications and does not condone or encourage any intellectual property infringement and disclaims any responsibility related thereto. These intellectual property licenses may differ from country to country and it is the responsibility of those who develop the concepts or applications to be aware of and comply with different national license requirements.

Dialogic, Diva, Eicon, Eicon Networks, Eiconcard and SIPcontrol, among others, are either registered trademarks or trademarks of Dialogic. Dialogic's trademarks may be used publicly only with permission from Dialogic. Such permission may only be granted by Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9. Any authorized use of Dialogic's trademarks will be subject to full respect of the trademark guidelines published by Dialogic from time to time and any use of Dialogic’s trademarks requires proper acknowledgement. The names of actual companies and products mentioned herein are the trademarks of their respective owners.

installed boards in slots along the length of the CT Bus cable rather than clustered in one area.

Attach the CT Bus cable to the Dialogic board as follows:

1.Attach the end connector on the CT Bus cable to the CT Bus edge connector on the top edge of the first board in the sequence. The connectors are designed to fit together one way only. If the connector does not seat fully on the board, turn the cable around and try again. Make sure that the colored stripe on the cable faces the rear bracket.

(Pin 1 Indicator)

 

D/xxx JCT

D/xxx

Board

 

Board

PCI Slots

ISA Slots

For more information, see the hardware installation instructions for the CT Bus/SCbus Adapter.

Note: Connect the Earth Recall signal to pin 2. DO NOT connect Tip or Ring lines to pin 2 or improper operation of the VFX/41JCT-LS will result.

9. Install Software, Configure and Test

Install the Dialogic® software release and configure the Dialogic® boards as described in the Dialogic®Installation and Configuration Guide for your operating system.

11. Sales Assistance

If you have a sales question, please contact your

local Sales Representative or the Regional Sales Office for your area. Address, telephone and fax numbers, are available at the Dialogic website located at: http://www.dialogic.com/contact.htm.

To purchase Dialogic® products, please refer to the following website to locate the appropriate supplier. http://www.dialogic.com/purchase.htm.

Image 2
Contents Protect Boards from Damage Install the BoardSet Hardware Switches Set CT Bus Jumpers optionalInstall Software, Configure and Test Complete Board InstallationWarranty and Return Information Connect External Cables