Dialogic®
Physical Description
DM3 Media Boards
Quick Install Card for PCI
DMV600BTEP
Part number:
Copyright ©
Dialogic Corporation.
All Rights Reserved.
Before You Begin
Protecting the Board from Damage
CAUTION
All computer boards are sensitive to
electrostatic discharge (“ESD”). Handle all static- sensitive boards and components at a
If you are not familiar with ESD safety precautions, visit http://www.dialogic.com/support/hwinstall to learn more.
Unpacking the Board
Unpack the Dialogic® DM3 Media Board (“board”) according to the following steps:
1. | Prepare a |
2. | Carefully remove the board from the shipping |
CH4 CH3 CH2 CH1
Red | 8 |
Yellow
Green
Loopback
7
6
5
3 4
2
1 | 1 |
|
2 | 10 |
|
JP2A
JP2B
1.
2.General Network Interface Alarm LED
3.Power LED
4.Reset LED
5.SW1: Rotary switch to set board identification (Linux systems only).
6.POST LEDs: Indicate Power On Self Test (POST) status during power up.
Alarm LEDs (CH1 and CH2 only): Indicate network alarms for each trunk.
9Red: Alarm to indicate loss of signal.
Yellow: Alarm to indicate loss of frame synchronization at far end of external network.
Green: Indicates signal present; powered up and receiving signal from external sources.
Loopback: Indicates loopback mode is activated.
7.CT/MVIP Bus Termination Jumpers: Bus signal is terminated when the corresponding jumper clip is installed. Signal must be terminated only on boards at each end of the CT Bus cable.
JP2A: CT Bus termination jumper
JP2B: MVIP Bus termination jumper
8.P3: CT Bus connector
9.ISA Edge Retainer
10.Signal Processing Daughterboard
carton and |
by the edges and avoid touching the board’s |
components. |
3. Lay the board on the |
surface. |
Note: Place boards in
CAUTION: Do not remove the board from the
Configuring the Hardware
Board Identification
The DM3 device driver, part of the system software, assigns board instance numbers in ascending order (beginning with 0) as it detects each board in your system. A board instance number is the identification (ID) number used by the system software to recognize the board.
NOTE: If you add or remove a board, the system may change the existing board instance (ID) numbers.
Windows System
After the hardware and the system software are installed, refer to the Dialogic® Configuration Manager (DCM) configuration utility to retrieve the board instance (ID) number(s) assigned to the board(s) in your system.
See the DCM online help for details about board identification.
Linux System
In a Linux system, you must set SW1 to a unique number for each DM3 board in your system. Use a
After the hardware and system software are installed, refer to the proper configuration files to retrieve the board instance (ID) number(s) assigned to the board(s) in your system.
For more information about Linux configuration files, see the Dialogic® Configuration Guide supplied with your system release.
Installing the Hardware
NOTE: Dialogic recommends that you install the hardware before the system software. However, if you are adding a DM3 board to an existing DM3 system, you do not need to uninstall existing DM3 software.
1.With your computer on the
2.Remove the chassis cover plate.
3.Select an empty PCI expansion bus slot and remove the slot’s retaining screw and access cover plate (if applicable).
4.If you are not installing your board in an ISA form factor PCI slot, remove the ISA edge retainer from the board.
5.Using the slot’s board guides, insert the edge connector of the board into the bus slot. Press firmly until the board is securely seated in the slot.