Digi X2 manual Test the IP address configuration

Page 67

C o n f i g u r e D i g i d e v i c e s

Test the IP address configuration

Once the IP address is assigned, test the IP address configuration to be sure it works as configured. This procedure assumes that the Digi device has an IP address.

1Access the command line of a PC or other networked device.

2Issue the following command:

ping ip-address

where ip-addressis the address assigned to the Digi device. For example:

ping 192.168.2.2

6 7

Image 67
Contents ConnectPort X Family User’s Guide E r ’ s G u i d e Contents N t e n t s Configure Digi devices N t e n t s N t e n t s N t e n t s N t e n t s Monitor and manage Digi devices 175 Administration tasks Specifications and certifications Index GlossaryN t e n t s Audience PurposeScope General release documentation Where to find more informationTo Contact Digi International Use Digi contact informationG i c o n t a c t i n f o r m a t i o n Introduction ConnectPort X Family products User interfaces FeaturesFeature/task Path to feature in the web interface See Quick reference for configuring featuresConfiguration Serial Ports port Profile Settings Configuration Network Advanced Network Settings Set mesh SSH Configuration Security Configuration System Device Identity Settings Network interface features Hardware featuresConfigurable network services IP protocol support Serial data communication over TCP and UDP Supported RFCs and MIBs Dynamic Host Configuration Protocol DhcpAuto-IP Simple Network Management Protocol SnmpTelnet Remote Login rloginSupported Snmp traps Secure Sockets Layer SSL/Transport Layer Security TLSAdvanced Digi Discovery Protocol Addp Internet Control Message Protocol IcmpPoint-to-Point Protocol PPP Network Address Translation NAT/Port ForwardingProvisioning wizard Mobile/Cellular features and protocol supportDigi SureLink Mobile/Cellular protocols Code-Division Multiple Access CdmaGlobal System for Mobile communication GSM Universal Mobile Telecommunications Service Umts General Packet Radio Service GprsEnhanced Data Rates for GSM Evolution Edge Evolution-Data Optimized EV-DO, EVDO, or 1xEV-DO IP address assignment alternatives Encrypted RealPort RealPort softwareModem emulation AlarmsSecurity features Customization capabilities Configuration managementNetwork services associated with specific serial ports Network servicesSupported connections and data paths in Digi devices Network services associated with the command-line interface Network services associated with serial ports in generalModem emulation pseudo-modem client connections Command-line interface CLI-based client connectionsNetwork/serial clients Autoconnect behavior client connectionsConfiguration capabilities Configuration capabilities and interfacesConfiguration interfaces Digi Device Setup wizard Page Digi Device Discovery utility Advantages of the Digi Device Discovery utility are Web interface Page Command-line interface Connectware Manager interface Connectware Manager Getting Started Guide Simple Network Management Protocol Snmp Digi enterprise MIBs supported Standard MIBs supportedAdditional Snmp resources Monitoring interfaces Monitoring capabilities and interfacesSnmp Connectware ManagerAdministration tasks Configure Digi devices Alternate methods for assigning an IP address Default IP addressConfigure an IP address using the Digi Device Setup Wizard My Computer CD ROM Drive setup.exeConfigure an IP address using Auto-IP Configure an IP address using DhcpIP addresses and Connectware Manager Configure an IP address from the command-line interfaceTest the IP address configuration Configuration through the web interface Open the web interface By using the Digi Device Discovery utilityInstall Digi Device Discovery utility Select Device Discovery Utility and click InstallDiscover devices Organization of the web interface Home Configuration pagesApply and save changes Cancel changesRestore the Digi device to factory defaults Application pagesChange the IP address from the web interface, as needed Configure network communications IP settings Alternatives for configuring network communicationsExclusion range Dhcp server settingsDhcp terminology ScopeOptions LeaseGrace period ReservationDhcp server configuration settings Addresses in the Dhcp server settingsPage Manage the Dhcp server Network services settings # ssh -l fred digi16 -p 2501 # telnet digi16 Addp Service Services provided Default Network Port NumberSnmp Network services and IP pass-through Settings Dynamic DNS update settingsPage Status and history information IP filtering settings IP forwarding settings Example Socket tunnel settings How IP pass-through works IP pass-through settingsN f i g u r e D i g i d e v i c e s Using pinholes to manage the Digi device How IP pass-through affects network access to Digi devicesRemote device management and IP pass-through Steps to configure IP pass-throughIP Pass-through Screen shot shows IP Pass-through configuration settings Uses for VPN-enabled Digi devices Virtual Private Network VPN settingsHow VPN tunnels work Example VPN configurationCdma carrier requirements HQ router / VPN appliance configurationIP address requirements for VPN tunnels GSM GPRS/EDGE APN type neededConfigure VPN settings Using a console portSetting Remote Site Digi Connect VPN VPN Concentrator N f i g u r e D i g i d e v i c e s Click VPN Internet Key Exchange IKE Settings Use the following as the identity Page Default Security Policies Page N f i g u r e D i g i d e v i c e s Page N f i g u r e D i g i d e v i c e s Tunnel Network Traffic to the following Remote Network Manual-keyed IPSEc/ESP VPN tunnel security settingsAlgorithm Size Enable Encryption Encryption algorithmAlgorithm Size Key Length Enable Authentication Authentication algorithmIsakmp VPN tunnel security settings Size Key Length VPN tunnel proposal configuration for Isakmp tunnels Advanced network settings GSM-based mobile service providers Configure mobile cellular settingsInformation required from mobile service provider CDMA-based mobile service providersMobile service provider settings Set mobile configuration settings to factory defaultsLaunch the Mobile Device Provisioning Wizard Provision a mobile deviceAutomatic versus manual provisioning Select a mobile service provider from the listExample provision ConnectPort WAN VPN for Sprint PCS Select automatic or manual provisioning Device provisioning in progress Provisioning complete Digi SureLink settings Mobile connection settingsLink integrity monitoring settings Hardware reset thresholdsN f i g u r e D i g i d e v i c e s Page Status and statistical information for mobile connections Mesh network terms ZigBee protocol Node ZigBee node types Configure Mesh/ZigBee network settingsCoordinator ZigBee stack RouterEnd device ZigBee protocol termsMaximum child end devices JoiningNetwork maximum depth Maximum child routersMesh Network configuration settings Page Basic radio settings Power Level Conducted Power DBm Advanced radio settingsClick Change Profile Configure serial portsSelect and configure a port profile About port profilesConsole Management profile RealPort profileAutomatic TCP connections autoconnection TCP Sockets profileRFC 2217 support UDP Sockets profile TCP and UDP network port numbering conventionsFor this connection type Use this Port Serial Bridge profile Local Configuration profileModem Emulation profile Custom Profile Basic serial settingsSerial Settings Advanced serial settingsCharacter Key Sequence TCP settingsHexadecimal \xhh Values Tab Line feed Backslash UDP settings Camera settings Configure camera settingsCamera operation Alarm notification settings Configure alarmsAlarm list Alarm conditionsAlarm conditions Enable and Disable Alarms Alarm destinationsSnmp configuration settings Configure system settingsDevice description information Steps for setting up remote management Configure remote management Connectware Manager settingsAbout client-initiated and server-initiated connections Connection settingsLast Known Address LKA Retry if the LKA update fails Client initiated management connection settingsMobile Settings Advanced remote management settingsUsername Alarms and the Connectware Manager server Configure Security settingsFor more information on Connectware Manager About user models and user permissions Password authenticationEnable password authentication From the command lineChange the password for administrative user Disable password authenticationUpload an SSH public key Disable unused and non-secure network servicesUse IP filtering Recommended distribution of Python interpreter Configure applicationsPython configuration pages Python program managementPython files Auto-start settingsManually execute uploaded Python programs Access the command line Configuration through the command lineVerify device support of commands To configure Use this command Set snmp N f i g u r e D i g i d e v i c e s Configuration through Connectware Manager ZigBee Networks View Node View N f i g u r e D i g i d e v i c e s What’s next? Batch capabilities for configuring multiple devicesMonitor and manage Digi devices Display system information Monitoring capabilities in the web interfaceGeneral system information Serial port information Serial port diagnosticsUp Time Total/Used/Free MemorySignals ConfigurationParity Errors Overrun ErrorsOverflow Errors Framing ErrorsNetwork statistics No Routes Default Time-To-LiveIP Statistics Datagrams Received Datagrams Forwarded ForwardingIcmp statistics UDP statisticsCell ID Signal Strength RssiMobile information and statistics Mobile Connection Statistics Registration StatusIP Address Idle ResetsInactivity Timer Mobile StatisticsModem Serial Number Mobile InformationPhone Number Modem ManufacturerSession consecutive failures SureLink statisticsSession successes Session failuresTotal bypasses DiagnosticsTotal failures Total link down requestsManage VPN connections Manage connections and servicesManage serial ports Manage connectionsStart, stop, and restart the Dhcp server Manage network servicesEvent logging Manage Dhcp server operationView and manage current Dhcp leases Reserved active Lease status typesAssigned active Assigned expiredUnavailable Address ReleasedManage Mesh networks Manage Mesh networks from the web interface Frames Sent Gateway device detailsNetwork view of the Mesh devices Python Application ZigBee Socket CountersSelf Addressed Errors Python Application ZigBee Socket Error CountsTransmit I/O Errors Not Joined ErrorsMesh device state pages Commands for displaying device information and statistics Monitoring capabilities from the command lineDisplay Info Show Set alarmSet buffer and display buffers Set snmpCommands for managing connections and sessions Configure Mesh network settings command syntax Commands for managing Mesh networks and nodesSet mesh Display Mesh network configuration settings command syntax PAN ID Display meshInfo zigbeesockets Monitoring capabilities from Connectware Manager Monitor/manage Mesh networks from Connectware Manager Monitoring Capabilities from Snmp Administration tasks Administration from the web interface Delete files Custom files are not deleted by device resetFile management Uploading FilesCertificate/Key Management Backup/restore device configurations Prerequisites Update firmware and Boot/POST CodeUpdate firmware from a file on a PC Update Firmware from a Tftp ServerSettings cleared and retained during factory reset Restore a device configuration to factory defaultsUsing the web interface WAN Using the Reset buttonEnable/disable access to network services Reboot the Digi deviceAdministrative task Command Administration from the command-line interfaceSpecifications and certifications ConnectPort X8 specifications Hardware specificationsSpecification Value Radio Frequency Interface RFI FCC Safety standardsRegulatory information and certifications FCC Part 15 Class BIndustry Canada Modifications FCCDeclaration of Conformity Standards ConnectPort International EMC StandardsImportant Safety Information 802.11 Access control listAddress Resolution Protocol ARP AlarmsCOM port redirection Configuration managementDynamic Host Configuration Protocol Dhcp Digi Device Setup WizardDevice server ESP Passthrough Encapsulating Security Payload ESPEncryption Enhanced Data Rates for Global Evolution EdgeFile Transfer Protocol FTP Factory defaultsGeneral Packet Radio Service Gprs High Speed Downlink Packet Access HsdpaHyperText Transfer Protocol over Secure Socket Layer Https HyperText Transfer Protocol HttpInternet Control Message Protocol Icmp IP filtering Internet Group Management Protocol IgmpIPsec Internet Protocol Security Mobile Device Provisioning Wizard Management Information Base MIBModem emulation Power-On Self Test PostPort forwarding RealPort Remote login rloginRlogin ProvisioningSerial tunneling Setup WizardSecure Sockets Layer SSL Serial bridgeTelnet Static IP address assignmentTTY port redirection Transmission Control Protocol TCPTransport Layer Security TLS Trivial File Transfer Protocol TftpUser Datagram Protocol UDP Universal Mobile Telecommunications Service UmtsZigBee To 255 devices in a single Wpan Index DCD 145 Dhcp Gprs NAT Local Configuration Modem Emulation PPP D e 151 TCP D e D e
Related manuals
Manual 254 pages 23.5 Kb Manual 1 pages 201 b

X2 specifications

Digi X2 and X1 are advanced cellular IoT (Internet of Things) gateways that provide an innovative solution for industrial applications, smart cities, and remote asset management. Both devices equip users with the means to connect, monitor, and control a wide variety of assets without the limitations traditionally imposed by wired connections.

Digi X2, designed for complex IoT demands, features dual SIM slots which ensures uninterrupted connectivity through automatic failover. This makes it particularly valuable for critical applications where connectivity is non-negotiable. Additionally, the X2 is equipped with LTE-M and NB-IoT support, enabling extensive coverage in areas where other networks may struggle.

On the software side, the Digi X2 supports Digi Remote Manager, a powerful tool that allows users to monitor, manage, and deploy devices remotely. This cloud-based management system simplifies the overall management of IoT devices by providing real-time insights, easy configuration changes, and over-the-air updates, saving both time and resources.

In contrast, the Digi X1 serves as an entry-level model that balances performance with cost-effectiveness. It supports LTE connectivity, providing a reliable connection suitable for a variety of applications. The X1 also offers seamless integration with existing networks, allowing users to leverage their current infrastructure while expanding their IoT capabilities.

Both Digi X2 and X1 are designed with ruggedness in mind, making them suitable for deployment in harsh environments. They are engineered to withstand extreme temperatures and vibrations, ensuring reliability even in demanding industrial settings.

Another notable characteristic of these devices is their extensive input/output (I/O) capabilities, which enable them to interact with sensors, machines, and other types of devices. This versatility allows for a broad spectrum of applications, from monitoring temperatures in remote locations to tracking assets across geographic boundaries.

In summary, the Digi X1 and X2 provide robust, reliable, and scalable solutions for modern IoT implementations. With their advanced cellular connectivity, cloud management capabilities, and durable design, they are poised to enhance connectivity across industries, driving efficiencies and enabling smarter operations. Whether for critical industrial applications or efficient asset management, Digi's offerings are tailored to meet the diverse needs of today's IoT landscape.