Edimax Technology ER-5398S Connecting network devices with coaxial cables, DIP Switch for

Page 10

4. Connecting network devices with coaxial cables

ER-5398S provides two auto-detect BNC/AUI coaxial ports, each can function as either BNC or as AUI but can be used at the same time. A set of configuration DIP switches are located between port 1 and port 2, they can be used to configure the coaxial port as auto-detect, BNC only or AUI only as illustrated in Figure 5-2 and Table 5-1.

NOTE : The default setting is auto- detect mode.

1

 

2

3

4

 

Figure 5-2 DIP Switch for

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

AUI/BNC port

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port 1

 

 

 

 

Port 2

1

2

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto

 

 

 

 

 

Auto

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUI

 

 

 

 

 

BNC

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

BNC

 

 

 

 

 

AUI

OFF

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUI

 

 

 

 

 

 

AUI

OFF

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 5-1 DIP Switch configuration for AUI/BNC port

When using the BNC port, attach the T-connector to the BNC port on the rear panel and connect the coaxial cables to the both open ends of the T-connector as illustrated in Figure 5-3. If the ER-5398S is at either end of the coaxial segment, make sure terminate the open end of T-connector with a 50-ohm terminator. When using the AUI port, firmly attach the AUI transceiver to the AUI port and secure the transceiver into the socket. The AUI transceiver’s SQE (Heart Beat) should be set off.

Note : Do not connect coaxial cable directly to the BNC port without using T- connector.

BNC 2

AUI 2

BNC 1

100-240VAC 1A

Power

AUI 1

 

Figure 5-3 Connect the coaxial cables

100-240VAC 1A

Power

BNC 2

AUI 2

BNC 1

AUI 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Push to the righthand side to fix

Figure 5-4 Connect the AUI transceiver

7

Image 10
Contents Ethernet Hub FCC Compliance Statement Contents Introduction ER-5398S TopologyFeatures Features & SpecificationsSpecification Package Contents Physical Description PanelLED LEDOperating Environment InstallationConnecting to network devices with UTP cable Uplink to Another Hub with UTP cableConnecting network devices with coaxial cables DIP Switch forConnecting the power Connect the powerPower LED is not lit Trouble-shootingAUI/BNC ports do not transmit Collision LED is constantly flashing Contact your dealer if problem persistPartition LED is lit Jabbler LED is constantly flashing