ConnectPRO SL218 specifications Troubleshooting, Symptom Possible causes Recommended solutions

Page 10

KVM Switch

Troubleshooting:

Ensure that all cables are well seated. Check that keyboard/mouse cables are not swapped. Label and bundle the cables for each computer to avoid confusion when connected to the StreamLine.

Symptom

Possible causes

Recommended solutions

Nothing works

Bad connection at the

Push the assembled drawer and

 

 

 

C-36 connectors

 

the KVM module box firmly

 

 

 

 

 

 

 

 

 

together leaving only 8mm (5/16

 

 

 

 

 

 

 

 

 

inch) space in between. Be sure

 

 

 

 

 

 

 

 

 

they are secured by two screws.

VGA

monitor

Another

keyboard

or

If the C-36 connector on the KVM

works

fine

but

mouse is

connected

to

module box connects to a KVM

keyboard

and

the rear side of the KVM

drawer, its Local console should

touch pad does

module box (marked with

not connect to any keyboard or

not work.

 

Local) when

the C-36

mouse.

 

 

 

 

 

connector

is

 

connected

 

 

 

 

 

 

to the KVM drawer.

 

 

 

 

 

 

 

Connection

 

inside

the

Verify if the KVM drawer is bad by

 

 

 

KVM

drawer

becomes

disconnecting it

from

the KVM

 

 

 

loose due to vibration.

 

module box (the C-36 connector

 

 

 

 

 

 

 

 

 

is not connected). Connect a

 

 

 

 

 

 

 

 

 

keyboard, mouse and monitor to

 

 

 

 

 

 

 

 

 

the Local port on the KVM

 

 

 

 

 

 

 

 

 

module box

and

another

 

 

 

 

 

 

 

 

 

computer to any of the PC ports

 

 

 

 

 

 

 

 

 

and use the KVM module box as

 

 

 

 

 

 

 

 

 

a stand-alone KVM switch.

Some

 

front

The buttons at the left side

Use a standard KVM switch box

panel

buttons

of the front buttons (the

 

 

 

do not work

KVM

Switch

section)

is

 

 

 

 

 

 

only effective if a KVM

 

 

 

 

 

 

switch

box

 

is directly

 

 

 

 

 

 

connected

to

 

the KVM

 

 

 

 

 

 

drawer by the C-36

 

 

 

 

 

 

connector.

 

 

 

 

 

 

 

No OSD screen

No

power

 

to

the

Establish power

by turning on

 

 

 

StreamLine

 

 

 

computers, wait, press left CTRL

 

 

 

Loose monitor connection

keys several times.

 

 

 

 

 

 

 

 

 

 

Monitor not multi-sync

 

Reconnect monitor

 

 

 

 

 

 

 

 

 

 

Use multi-sync monitor

 

Keyboard

error

Loose keyboard

 

Make sure keyboard cables are

on boot

 

connection

 

 

 

 

Well seated

 

 

Master/slave

Improper installation

 

Make sure slave’s CONSOLE is

does not work

procedures

 

 

 

 

connected to Master’s PC 1~ PC

 

 

 

 

 

 

 

 

 

8 port

 

 

 

 

 

 

 

 

 

 

 

Press and hold the 1 and 2 push

 

 

 

 

 

 

 

 

 

buttons to initiate K/M reset

19

KVM Switch

 

 

 

 

 

 

 

Remove

any

possible

power

 

 

 

 

 

 

 

supply to the slave (unplug all

 

 

 

 

 

 

 

cables), before connecting it to

 

 

 

 

 

 

 

the Master

 

 

 

 

 

 

Keyboard

 

The computer was in

Press both SHIFT keys

 

 

 

strokes shifted

shifted state when last

 

 

 

 

 

 

 

 

 

 

 

switched

 

 

 

 

 

 

 

 

 

 

 

 

Theéand

 

All PCs are off or only one

Turn computers on.

 

 

 

 

êkeys do

not

PC is

turned

on.

Scan

 

 

 

 

 

 

 

 

 

work in Manual

mode works for power-on

Press

any

other key

to

abort

Scan

 

computers only

 

Manual Scan mode.

 

 

 

 

 

 

Scan

type

is

eye

mark

Set proper Scan type in OSD and

 

 

selected but no PC is eye

determine

which PCs

are eye

 

 

mark selected in OSD.

mark selected, do it in OSD.

 

Auto Scan does

All PCs are off or only one

Turn on computers

 

 

 

 

not switch

PC

PC is

turned

on.

Scan

 

 

 

 

 

 

 

 

 

and

the

mode works for power-on

Set proper

Scan Type in OSD

StreamLine

computers only

 

and determine which PCs are

beeps from time

 

 

 

 

 

eye mark selected, do it in OSD.

to time and red

Scan type is eye mark

 

 

 

 

 

 

 

 

 

indicator

 

selected but no power-up

Press

left

CTRL key

twice

to

flashes

 

PC is eye mark selected in

abort Auto Scan mode.

 

 

 

 

 

OSD.

 

 

 

 

Press any front button to select a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PC, and Auto Scan stops

 

 

Double OSD

 

Improper slave connection

Press push buttons 1 and 2 down

images at

 

procedure.

 

 

 

for 2 seconds to activate K/M

cascade

 

 

 

 

 

 

RESET

 

 

 

 

 

 

 

 

configuration

 

 

 

 

 

Remove

any

possible

power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supply to the

Slave (unplug all

 

 

 

 

 

 

 

cables), before connecting it to

 

 

 

 

 

 

 

the Master

 

 

 

 

 

 

OSD menu is

OSD

menu

has

fixed

Use <F4>:More\Position to select

not at the

 

resolution

and its

size

UL or

UR.

OSD

menu

may

proper position

varies

due

to

computer

appear near the middle of the

 

 

VGA resolution changes.

screen

when

LL

or

LR

is

 

 

 

 

 

 

 

selected.

 

 

 

 

 

 

 

Computer

can

Loose mouse adapter

Secure

the

mouse

adapter

to

not use serial

 

 

 

 

 

computer’s COM port

 

 

 

mouse

 

Incorrect mouse adapter

Use only the mouse adapter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

comes with the unit

 

 

 

 

 

 

Incorrect

PC

port

The mouse

conversion is only

 

 

connection

 

 

 

effective at PC ports 7 and 8.

 

Can not select a

Improper Master unit

 

Only Master ports PC1~PC8 can

computer

 

connection

 

 

 

be connected to slaves.

 

 

connected to a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

slave

 

Improper slave unit

 

Connect slave CONSOLE port to

 

 

connection

 

 

 

PC1~PC8 ports of the Master

 

 

 

Too many levels of slaves

Only one level of slave units is

 

 

 

 

 

 

 

allowed. Pop up OSD again to

20

Image 10
Contents KVM Switch Configurations Features for OSD menuInstallation Device Connection Cascade StreamLine configurationFront Panel Push Buttons Initial Power-UpOperation OSD On-Screen-Display OperationAuto Scan Manual Scan Hot-key commands Cascade Configuration ConnectionSpecifications Change Configuration while RunningAppendices Troubleshooting Symptom Possible causes Recommended solutionsLimited Warranty