B&B Electronics ES1AE manual UDP Client Settings

Page 30

Using the Web Configuration and Management Interface

Figure 11. UDP Server Settings

UDP Client Settings

If your ES1A is configured as a UDP client you can automatically distribute serial data from you ES1A to many devices at the same time. This is sometimes referred to as Data Distribution or UDP Multicast.

Figure 12. UDP Client Settings

You can configure multiple destinations. In the appropriate boxes, type the Description, Send To IP address or DNS name and UDP Port number, then click Add. You can also configure the conditions under which to send data.

Consult the Tutorial and online Help for more detail.

20

Manual Documentation Number: ES1A -2907m pn7041-rev002

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445www.bb-europe.com

Image 30
Contents Mini Ethernet to RS-232 Converter Model ES1AEManual Documentation Number ES1AE-2907m International Headquarters Page Manual Documentation Number ES1AE-2907m pn7041-rev002 Page Table of Contents Managing the ES1A Manual Documentation Number ES1AE-2907m Pn7041-rev002 Iii Manual Documentation Number ES1AE-2907m pn7041-rev002 Features IntroductionDirect IP Paired ModeCommunication Modes Virtual COM PortOther Communications Modes 4Manual Documentation Number ES1A -2907m pn7041-rev002 Package Checklist Hardware OverviewEthernet Port Connector Indicators, Switches and ConnectorsReset Switch Link Integrity LED YellowPower Connector Connecting the HardwareSerial Port Connector Configuration Connections8Manual Documentation Number ES1A -2907m pn7041-rev002 Check the contents of your ES1A package. It should contain… Getting StartedConfigure the ES1A Configuring the IP Address Using the Discovery SoftwareConfiguring the ES1A Using the Web Configuration and Management Interface LoggingLogging Out Using Tutorial and Help Configuring Network SettingsIP Settings Network Services SettingsAdvanced Network Settings Configuring the Serial Port Port Profile SettingsRealPort TCP Sockets UDP Sockets UDP Client Settings Basic Serial Settings Advanced Serial SettingsConfiguring Alarms and Notification Alarm Notification SettingsAlarm Conditions Alarm Destinations Using the Web Configuration and Management Interface Managing the ES1A System SettingsUsing Remote Management Managing Users and PermissionsConfiguring User Access and Permissions Adding New UsersManaging Serial Ports and Connections Serial PortsConnections Managing the ES1A Backup/Restore Using Administrative FeaturesFactory Default Settings Update FirmwareSystem Information GeneralSerial Serial Port Diagnostics NetworkReboot Using RealPort Configuring the IP AddressConfiguring the Serial Port for RealPort Adding a Virtual COM Port using RealPort Removing a Virtual COM Port using RealPortUpdating RealPort Using RealPort Appendix a Default Configuration Settings TCPDefault Configuration Settings Appendix B Product Specifications Manual CD-ROM diskProduct Specifications Appendix C Dimensional Diagrams Dimensional Diagram of the ES1AAppendix D RS-232 Connections DTERJ-45 Pin Signal Wire Color Appendix E Network Connections