Buffer-Based Trigger
The
Digital Input Trigger
The digital input trigger dials the modem when an input signal is detected on the DCDSS1 digital input. It is a +5 volt signal, which can be set to active high or active low. The signal must stay active for at least 5 milliseconds to be detected.
Data Delivery Methods
Data and error logs can be emailed using a MIME attachment or sent using FTP. Additionally, notifications can be configured to allow email or pager notification that data has been delivered.
Error Conditions
The DCDSS1 has a 2.9 Kbyte error log buffer for storing error conditions. Each error condition is time stamped.
| Error Condition Logged |
| Cause |
|
|
|
| Data received from the local serial | |||
| BYTE(S) LOST | port during ISP communications or | |||
|
| when in Bypass Mode is not stored | |||
| DATA OVERRUN | Onboard UART FIFO overflowed |
|
| |
| DATA ERROR | Character received with parity, |
|
| |
| framing or break error |
|
| ||
|
|
|
| ||
|
| An error occurred in the email |
|
| |
| NOTIFICATION FAILED | notification process (mail server |
|
| |
| connection, command structure, |
|
| ||
|
|
|
| ||
|
| etc.) |
|
|
|
|
| An error occurred in the email data | |||
| DATA ATTACHMENT FAILED | process (mail server connection, |
|
| |
|
| command structure, etc.) |
|
| |
| ERROR ATTACHMENT | An error occurred in the email error | |||
| log process (mail server connection, | ||||
| FAILED | ||||
| command structure, etc.) |
|
| ||
|
|
|
| ||
| FTP FAILED | An error occurred in the FTP |
|
| |
| process (FTP server connection, |
|
| ||
|
|
|
| ||
|
|
|
|
|
|
| Documentation Number DCDSS11702 Manual | Appendix A | 3 |
|
B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph