Chapter 7
Table | |
|
|
Field | Description |
|
|
|
|
Sample Type | The method used for monitoring the variable. Possible |
| options are: |
| • Rate - The alarm uses the counter’s rate in the last |
| interval. |
| • Total - The alarm uses the absolute number of the |
| counter from the time the device was last reset. |
| * Note: The Alarms and Events tool can only |
| configure alarms using the Rate method. To |
| configure alarms based on the absolute |
| number of packets, use the CLI (Command |
| Line Interface) or a |
|
|
Startup Alarm | The type of event that can be generated as the first event |
| for the alarm. Possible types are: |
| • Rising - The first event that can be generated must |
| be a Rising Event. If the rate falls below the Falling |
| Threshold before it rises above the Rising Threshold, |
| a Falling Event is not generated. |
| • Falling - The first event that can be generated must |
| be a Falling Event. If the rate rises above the Rising |
| Threshold before it falls below the Falling Threshold, |
| a Rising Event is not generated. |
| • Rising and Falling - The first event generated can |
| be a Rising or a Falling Event. |
|
|
Rising Threshold | The upper threshold for the counter. |
|
|
Falling Threshold | The lower threshold for the counter. |
|
|
Owner | The owner of the alarm. This is usually the person who |
| created the alarm. |
|
|
46 | Avaya C460 SMON User Guide |