Bay Technical Associates DS74 manual Port Device Type, Unit responds with the port’s current type

Page 11

DS74 Serial I/O Module

+

----+------

+

-----------------Device

+

------+------

+------

+------

+---------

+----

+----

+

PortDevice

Baud Word Stop

ParityHandshakeLineDrive

Type

Name

Rate Size Bits

DTR

RTS

+

----+------

+

-----------------

+

------+------

+------

+------

+---------

+----

+----

+

1 RS232 Device A

9600 8

1

None None

HI

HI

+

----+------

+

-----------------

+

------+------

+------

+------

+---------

+----

+----

+

Enter Port Device Name

(Max. 16

characters):

 

 

 

 

 

 

 

or press ENTER for no

change .....:test

 

 

 

 

 

 

NOTE: Once you make a change to the Port Device Name, you have to back out of the menu and will be asked to Accept changes. If you type ‘y’ for yes, the changes take effect immediately for the serial port.

Accept changes ? (Y/N) :y

Type ‘Y’ for YES or ‘N’ for NO and press <cr>.

Changes accepted.

Port Device Type

There are two configurations of port types. The standard RS-232 is the basic configuration for transfer of data. RPC-SNMP is allows the port to be monitored through SNMP protocol. The host module will poll the port at a predetermined time based on the firmware and displays the RPC/RPS SNMP ID data from the unit connect to the port on the host main menu. Default is RS-232 Type

NOTE: If no RPC/RPS with SNMP enabled device is connected to the port, the host module will wait approximately 40 seconds for the port to respond to it’s polling upon power up or host module unit reset and display the following: No communication with RPC at Module # Port #

Select the port you want to change the TYPE, followed by a <cr>.

Enter Serial Port Number (? = Help, ENTER = Exit) :1

The unit responds with the port’s current type.

 

Module 2, Port 1 device type: RS232

Note: Changing port type will force a unit reset when configuration is exited

RS-232

1

RPC-SNMP

2

Exit

X,CR

Enter Request :2

 

Selecting either option the module responds with the DS74 Configuration Menu.

NOTE: Once you make a change to the port type, you have to back out of the Port Type menu and will be asked to Accept changes. If you type ‘Y’ for YES, the changes take effect immediately for the serial port.

Accept changes ? (Y/N) :y

11

Image 11
Contents DS Series Manual DS74 Serial I/O Module RTS/DTR Line Driver Inactivity State Cabling DS74 EIA-232 RJ-45 SignalAdapters Signals Signal RS-232 COM Port Port DS Port RPC DE-9 Pin DB-25 PinAdapters Serial SetupDS74 Configuration Menu Unit Configuration MenuHandshaking Serial Port ConfigurationStatus Baud Rate Parity Word SizeStop Bits RTS/DTR Line Driver Inactivity State Port Device NameUnit responds with the port’s current type Port Device TypeVerify DS74 is functioning Reset DS74 ConfigurationExceptions BayTech Product WarrantyBayTech Extended Warranty Repair and Return Policy Technical SupportReturn Authorization Process