Avocent 3050, 3100, 3200 manual Managing local accounts, Access levels

Page 56

44AutoView 3050/3100/3200 Switch Installer/User Guide

To force upgrade the IQ module firmware using the AutoView 3050/3100/3200 switch on-board web interface:

1.From the side navigation bar, select Appliance - Appliance Settings - Ports - IQ modules.

2.Select the IQ modules that you wish to upgrade and click the Upgrade button.

CAUTION: Disconnecting an AutoView 3050/3100/3200 switch or IQ module or turning the user’s computer off and then on again during a firmware update may render it inoperable and require it to be returned to the factory for repair.

Managing local accounts

The AutoView 3050/3100/3200 switch OBWI provides local and login security through administrator-defined user accounts. By selecting Local Accounts on the side menu bar, administrators may add and delete users, define user preemption and access levels and change passwords.

Access levels

When a user account is added to the OBWI, the user may be assigned to any of the following access levels:

Appliance administrators

User administrators

Users

Table 4.3: Allowed Operations by Access Level

Operation

Access Level

Appliance

Administrator

User

Administrator

Users

Configure OBWI system-level settings

Yes

No

No

 

 

 

 

Configure access rights

Yes

Yes

No

 

 

 

 

Add, change and delete user accounts

Yes, for all

Yes, for users and

No

 

access levels

user administrators

 

 

 

only

 

 

 

 

 

Change your own password

Yes

Yes

Yes

 

 

 

 

Access target device

Yes, all target

Yes, all target

Yes, if allowed

 

devices

devices

 

 

 

 

 

Image 56
Contents AutoView 3050/3100/3200 USA Notification Canadian Notification AutoView 3050/3100/3200 Switch Power On Table of Contents Web Interface Operations Console Menu Appendices List of Figures Active Directory KVM Appliance Admin List of Tables AutoView 3050/3100/3200 Switch Installer/User Guide Features and Benefits Reduce cable bulkExample Switch Configuration AutoView 3100/3200 shown AutoView 3050/3100/3200 Switch Connectivity Installation OverviewAutoView 3050/3100/3200 Switch Installer/User Guide Setting up your network Supplied with the AutoView 3050/3100/3200 switchGetting started Additional items neededTo install the rack mounting bracket Rack Mounting an AutoView 3050/3100/3200 SwitchRack mounting safety considerations Connecting the AutoView 3050/3100/3200 Switch Hardware To connect and turn on your AutoView 3050/3100/3200 switchTo connect a serial IQ module to a serial device Configuring the AutoView 3050/3100/3200 SwitchSetting up the built-in web server Connecting to the Obwi through a firewall IQ and serial IQ modules AutoView 3050/3100/3200 switchVerifying the Connections Adjusting Mouse Settings on Target Devices AutoView 3050/3100/3200 Switch Installer/User Guide Basic Operations Viewing and selecting ports and serversSelecting a target device To select a target deviceSoft switching To soft switch to a target deviceTo select the previous target device To disconnect from a target deviceNavigating the Oscar interface Local Port OperationTo access the Oscar interface Main dialog box Main Dialog Box FunctionsSetup Dialog Box Functions Managing a KVM sessionTo access the Oscar interface Setup dialog box Oscar Interface Setup Dialog BoxTo access the Oscar interface Menu dialog box To set a Screen Delay Time for the Oscar interfaceChanging the display behavior To choose the display order of target devicesTo determine how the status flag is displayed To access the Oscar interface Flag dialog boxControlling the status flag To access the Oscar interface Broadcast dialog box Selecting target devices for broadcastingSelecting target devices for Scan mode To select the target devices for broadcastingTo add target devices to the Scan list Oscar Interface Scan Dialog BoxSetting local port Screen Saver options To access the Oscar interface Screen Saver dialog boxTo remove a target device from the Scan list To set the Screen Saver optionsTo immediately activate the screen saver Setting the keyboard country codeTo exit Screen Saver mode and log in to the local port To set the keyboard country code for Sun servers Configuring network settingsTo set the Ethernet Mode To configure the IP address To enable or disable the Ping ResponseConfiguring the IP address To access the Oscar interface Devices dialog box Assigning device typesTo assign a device type 12 Oscar Interface Devices Dialog BoxTo assign names to target devices To access the Oscar interface Names dialog boxAssigning target device names Commands Dialog Box Functions To list target devices alphabetically by nameTo access the Oscar interface Commands dialog box Enabling or disabling BroadcastingTo turn Broadcasting on To turn Broadcasting offEnabling or disabling Scan mode Viewing and disconnecting user connectionsTo start the Scan mode To cancel Scan modeTo disconnect a user 17 Oscar Interface User Status Dialog BoxDisplaying version information To display version informationResetting your PS/2 keyboard and mouse To reset the PS/2 mouse and keyboard valuesSending a ping request To send a ping requestAutoView 3050/3100/3200 Switch Installer/User Guide AutoView 3050/3100/3200 Switch Obwi Web Interface OperationsAutoView 3050/3100/3200 Explorer Window To log in to the AutoView 3050/3100/3200 switch ObwiViewing and Selecting Ports and Servers Using the side navigation bar Web Interface OperationsUsing the top option bar Launching a KVM SessionManaging the AutoView 3050/3100/3200 Switch Obwi To disconnect an active KVM session administrator onlyUpgrading IQ modules To delete offline IQ modulesAccess levels Managing local accountsRebooting the appliance Preemption levelsViewing and changing appliance configuration information Managing Device PropertiesConfiguring Ldap Ldap authentication priorityTo configure Ldap authentication priority parameters Ldap Overview parametersTo configure Ldap server parameters Ldap Search parametersTo configure Ldap search parameters Ldap Search Page in the ObwiLdap Query parameters To configure Ldap query parameters Appliance and Target Device Query ModesActive Directory KVM User Active Directory KVM Appliance Admin Setting up Active Directory for Performing Queries To set up group queriesWeb Interface Operations AutoView 3050/3100/3200 Switch Installer/User Guide Video Viewer Video Viewer WindowSession time-out Video Viewer Window FeaturesTo enable, disable or configure the session time-out Video Viewer Setting the window size Adjusting the viewTo change the Video Viewer window resolution Changing the toolbarTo refresh the screen To enable or disable Full Screen modeTo align the mouse cursors Adjusting color depth Additional video adjustmentTo enable full or manual scaling To manually adjust the video quality of the windowTarget video settings Automatic video adjustment Contrast and brightnessDetection thresholds Block Noise Threshold and Pixel Noise ThresholdAdjusting mouse options Refresh ImageVideo Test Pattern Cursor typeTo enter Single Cursor mode To select a key for exiting Single Cursor modeTo exit Single Cursor mode To change the mouse cursor settingVendor-specific video settings Mouse scalingMouse alignment and synchronization To set mouse scalingTo set Avocent Mouse Sync from the Video Viewer Avocent Mouse SyncTo realign the mouse Using Keyboard Pass-through Using MacrosTo specify keyboard pass-through To send a macroSaving the View Closing a Video Viewer Window SessionTo capture the Video Viewer window to a file To capture the Video Viewer window to your clipboardNetwork Configuration To connect a terminal to the AutoView 3050/3100/3200 switchTo configure network settings using the Console menu Console MenuConsole Main Menu Security Configuration Enable Debug MessagesConsole Password Other Console Main Menu OptionsExit Restore Factory DefaultsReset Appliance Appendix a Flash Upgrades Using the Console menu interfaceUsing the Obwi Recovering from a failed Flash upgradeTo upgrade the AutoView 3050/3100/3200 switch firmware To recover from a failed Flash upgradeSerial IQ module modes Appendix B Using Serial IQ ModulesConfiguring the serial IQ module Ctrl-F8 Using History mode To configure a serial IQ moduleCreating a serial IQ module macro To create a macroTo use History mode Serial IQ module pinoutsUTP copper cabling Wiring standardsAppendix C UTP Cabling Cabling installation, maintenance and safety tips Appendix D Technical Specifications DDC2BLocal Port Appendix E Sun Advanced Key Emulation AutoView 3050/3100/3200 Switch Installer/User Guide To resolve an issue Appendix F Technical SupportAutoView 3050/3100/3200 Switch Installer/User Guide Page For Technical Support 590-640-501E
Related manuals
Manual 2 pages 38.58 Kb

3200, 3050, 3100 specifications

The Avocent 3100 and 3050 are leading models in the KVM (Keyboard, Video, Mouse) over IP technology space, designed to provide robust and efficient server management for data centers and corporate environments. These units are part of Avocent's renowned portfolio of management solutions aimed at enhancing IT operations and accessibility.

One of the standout features of both the Avocent 3100 and 3050 is their ability to remotely manage servers, allowing IT administrators to connect to multiple machines from virtually anywhere with an internet connection. This remote capability is essential for reducing downtime as it permits troubleshooting, configuration, and even rebooting of systems without the need for physical presence in the server room. This is especially beneficial for businesses with data centers located in various geographic regions.

Both models possess high-definition video support, with resolutions up to 1920x1200, ensuring that administrators can view critical system interfaces clearly. The advanced video technologies present in these units facilitate seamless integration with high-resolution displays, maximizing the efficiency of server management tasks.

User friendliness is another hallmark of the Avocent 3100 and 3050. They come equipped with a straightforward web-based interface that streamlines the administrative process. This intuitive design allows users to quickly navigate through system settings and configurations, making it easy for even less experienced staff members to manage resources effectively. Additionally, these devices support multiple languages, accommodating diverse teams across global operations.

Security is paramount in any IT management tool, and Avocent has prioritized this by integrating robust security protocols. Both models support the use of SSL encryption, secure access controls, and user authentication methods, ensuring that sensitive data and system integrity are protected from unauthorized access.

The hardware characteristics of these units also reflect durability and reliability. They are built with quality components to ensure longevity in continuous operating environments common in data centers. Energy-efficient designs contribute to lower operating costs, aligning with modern sustainability goals.

In summary, the Avocent 3100 and 3050 are advanced KVM over IP devices that combine high-definition video capabilities, user-friendly interfaces, and strong security measures, making them invaluable tools for IT professionals managing complex server environments. Their robust engineering guarantees prolonged performance, ultimately driving business efficiency and success in an increasingly digital landscape.