each type of query has three modes that utilize certain types of information to determine whether or not an LDAP user has access to an appliance or connected target devices.

You can configure the following settings on the LDAP Query Page:

The Query Mode (Appliance) parameters determine whether or not a user has access to the appliance.

The Query Mode (Server) parameters determine whether a user has user access to servers connected to an appliance. The user does not have access to the appliance, unless granted by Query Mode (Appliance).

The Group Container, Group Container Mask and Target Mask fields are only used for group query modes and are required when performing an appliance or device query.

The Group Container field specifies the organizational unit (ou) created in Active Directory by the administrator as the location for group objects. Group objects are Active Directory objects that can contain users, computers, contacts and other groups. Group Container is used when Query Mode is set to Group Attribute. Each group object, in turn, is assigned members to associate with a particular access level for member objects (people, appliances and target devices). The access level associated with a group is configured by setting the value of an attribute in the group object. For example, if the Notes property in the group objects is used to implement the access control attribute, the Access Control Attribute field on the LDAP Query Page should be set to info. Setting the Notes property to KVM User Admin causes the members of that group to have user administration access to the appliances and target devices that are also members of that same group.

The Group Container Mask field defines the object type of the Group Container, which is normally an organizational unit. The default value is “ou=%1”.

The Target Mask field defines a search filter for the target device. The default value is “cn=%1”.

The Access Control Attribute field specifies the name of the attribute that is used when the query modes are set to User Attribute or Group Attribute. The default value is info.

To configure LDAP query parameters:

1.Select Configure-Appliance-Authentication-Search.

2.Select either Basic, User Attribute or Group Attribute for the Appliance Query Mode and the Server Query Mode.

3.Enter the appropriate information in the Group Container, Group Container Mask, Target Mask and Access Control Attribute fields.

4.Click Save.

NOTE: These options cannot be changed if the LDAP Priority is set to LDAP Disabled on the Overview screen.

Appliance and Server Query Modes

One of three modes can each be used for Query Mode (Appliance) and Query Mode (Server):

Image 74
Contents Autoview 3008/3016 USA Notification Canadian Notification AutoView 3008/3016 Switch Power On Table of Contents Web Interface Operations Video Viewer Appendices List of Figures 10 Versions Window List of Tables AutoView 3008/3016 Switch Installer/User Guide Features and Benefits Reduce cable bulkAutoView 3008/3016 Switch Installer/User Guide AutoView 3008/3016 Switch Connectivity Installation OverviewBasic AutoView 3016 Switch Configuration Getting started Setting up your networkSupplied with the AutoView 3008/3016 switch Additional items neededRack mounting safety considerations Rack Mounting an AutoView 3008/3016 SwitchConnecting the AutoView 3008/3016 Switch Hardware To install the rack mounting bracketTo configure network settings via the Oscar interface To configure network settings via the ObwiTo connect a serial IQ module to a serial device Adjusting Mouse Settings on Target DevicesConnecting to the Obwi Through a Firewall To configure the firewall Verifying the Connections Cascading AutoView SwitchesAutoView 3008/3016 switch IQ and serial IQ modulesInstallation AutoView 3008/3016 Switch Installer/User Guide To access the Oscar interface Main dialog box Basic Operations Main Dialog Box FunctionsTo select a target device Viewing and selecting ports and serversSelecting a target device To select the previous target deviceSoft switching To soft switch to a target deviceNavigating the Oscar interface Shift-Shift and/or Alt-AltSetup Dialog Box Functions Local Port OperationChanging the display behavior To choose the display order of target devicesControlling the status flag To set a Screen Delay Time for the Oscar interfaceTo access the Oscar interface Flag dialog box To change how the Oscar interface is invokedTo determine how the status flag is displayed Oscar Interface Flag Dialog BoxSetting the keyboard country code To set the keyboard country code for Sun serversTo access the Oscar interface Devices dialog box Configuring network settingsTo change network settings Assigning device typesTo assign a device type Oscar Interface Devices Dialog BoxAssigning target device names To assign names to target devicesCommands Dialog Box Functions 11 Oscar Interface Name Modify Dialog BoxTo add target devices to the Scan list Selecting target devices for Scan modeTo access the Oscar interface Commands dialog box To cancel Scan mode Enabling or disabling Scan modeTo start the Scan mode Viewing and disconnecting user connections To disconnect a userTo display version information and upgrade firmware Displaying version information and upgrading firmware16 Oscar Interface Version Dialog Box Select an Avriq module to view and click the Version button Returning an Avriq module to factory default status To issue a remote PS/2 reset commandTo reset the local mouse and keyboard AutoView 3008/3016 Switch Installer/User Guide AutoView 3008/3016 Switch Obwi Web Interface OperationsAutoView 3008/3016 Explorer Window To log in to the AutoView 3008/3016 switch ObwiViewing and Selecting Ports and Servers Web Interface Operations To disconnect a user session Launching a KVM SessionViewing and terminating user sessions Session sharing options Disconnect Session Status WindowTo connect to target devices when sharing is enabled Session Sharing Definitions TermManaging users Managing the AutoView 3008/3016 switch ObwiAccess levels Setting up user accounts Modifying users To add or modify a userUsers Window To delete a user To change a user password or access levelTo configure user rights to specific servers Locking and unlocking user accountsViewing and changing appliance configuration information Managing Device PropertiesTo enable, disable or configure the session time-out Session time-outTo enable NTP functionality Configuring an Override Admin AccountEnabling and configuring Snmp To configure an Override Admin AccountTo configure general Snmp settings Snmp WindowViewing and resynchronizing server connections Enabling individual Snmp trapsModifying a server name To modify a server nameViewing and configuring cascaded switch connections Viewing the IQ modules and IACsTo configure a cascaded switch connection Viewing version informationAvriq versions To view version information for Avriq modulesUpgrading firmware To reset an Avriq moduleTo upgrade appliance firmware To upgrade Avriq module firmware 12 Upgrade Appliance Firmware Tftp Server WindowTo reboot the switch Rebooting the switchManaging AutoView switch configuration files 14 Save Appliance Configuration Window File System To restore a user database file to a AutoView switch To restore a configuration file to an AutoView switchTo save a user database from a AutoView switch Managing user databases16 Restore Appliance User Data File System Window To configure Ldap authentication priority parameters Configuring LdapLdap authentication priority Ldap Overview parametersLdap Search parameters To configure Ldap server parametersTo configure Ldap search parameters Ldap Query parametersTo configure Ldap query parameters Appliance and Server Query ModesSetting up Active Directory for performing queries To set up group queriesInstalling a Web Certificate To install a web certificate18 Install Web Server Certificate Window AutoView 3008/3016 Switch Installer/User Guide Video Viewer Window Features Video Viewer WindowAutoView 3008/3016 Switch Installer/User Guide Changing the toolbar Setting the window sizeTo change the Video Viewer window resolution To specify a toolbar hide timeTo align the mouse cursors Adjusting the viewTo enable or disable Full Screen mode To refresh the screenTo enable full or manual scaling Adjusting color depthAdditional video adjustment To manually adjust the video quality of the windowClick the Manual Video Adjust button Contrast and brightness Target video settingsAutomatic video adjustment Detection thresholdsVideo Test Pattern Adjusting mouse optionsRefresh Image Cursor typeTo enter Single Cursor mode To select a key for exiting Single Cursor modeMouse scaling To exit Single Cursor modeTo change the mouse cursor setting To set mouse scalingMouse alignment and synchronization Using Keyboard Pass-throughVendor-specific video settings To realign the mouseUsing Macros Saving the ViewClosing a Video Viewer Window Session To close a Video Viewer window sessionAutoView 3008/3016 Switch Installer/User Guide To configure network settings using the Console menu Network ConfigurationTo connect a terminal to the AutoView 3008/3016 switch Console MenuOther Console Main Menu Options Exit Set Web Interface PortsInput Web Server Certificate AutoView 3008/3016 Switch Installer/User Guide Appendix a Flash Upgrades Using the Console menu interfaceRecovering from a failed Flash upgrade To recover from a failed Flash upgradeSerial IQ module modes Appendix B Using Serial IQ ModulesConfiguring the serial IQ module Ctrl-F8 Creating a serial IQ module macro Using History modeTo configure a serial IQ module To create a macroTo use History mode Serial IQ module pinoutsUTP copper cabling Wiring standardsAppendix C UTP Cabling Cabling installation, maintenance and safety tips Appendix D Technical Specifications DDC2BLocal Port Appendix E Sun Advanced Key Emulation AutoView 3008/3016 Switch Installer/User Guide To resolve an issue Appendix F Technical SupportAutoView 3008/3016 Switch Installer/User Guide Page 590-920-501C

3016, 3008/3016, 3008 specifications

The Avocent 3008, 3016, and 3016 KVM (Keyboard, Video, Mouse) switches are advanced solutions in the field of IT management, designed for data center environments that require seamless control over multiple servers and devices. These switches are known for their reliability, performance, and user-friendly features, making them essential tools for system administrators and IT professionals.

One of the primary features of the Avocent 3008 and 3016 series is their capability to manage multiple servers simultaneously. The model numbers denote the number of devices that can be controlled, with the 3008 supporting up to eight servers and the 3016 accommodating up to sixteen. This allows IT professionals to maximize their control and minimize the physical hardware required in server rooms.

Both the 3008 and 3016 support high-definition video output, ensuring that users receive clear and crisp visual displays from their servers. The ability to handle resolutions up to 1920x1200 at high refresh rates facilitates smooth and efficient operation, especially for graphics-intensive applications. The integrated video compression technology further enhances this capability by ensuring optimal video performance across different server configurations.

Security is another critical aspect of the Avocent switches. They come equipped with advanced user authentication and access management features, which prevents unauthorized access to the connected devices. The switches comply with various security standards, ensuring that sensitive data is protected throughout the management process.

The Avocent 3008 and 3016 also boast an intuitive on-screen display (OSD) that simplifies the user interface. This feature enables users to easily navigate between connected servers, manage settings, and access administrative functions with minimal effort. In addition, they support a variety of connection interfaces, including USB and PS/2, to accommodate different types of keyboards and mice.

In terms of connectivity, the Avocent switches support both local and remote access, allowing system administrators to manage servers from anywhere within the network. This flexibility is essential for modern IT operations, where remote management has become a standard practice.

Overall, the Avocent 3008 and 3016 series KVM switches offer robust features, advanced technology, and user-friendly designs. Their ability to manage multiple servers efficiently, combined with high-definition video support, enhanced security measures, and flexible connectivity options, makes them ideal for any data center looking to optimize its IT management processes. Whether for small businesses or large enterprises, these KVM switches help streamline operations and improve overall productivity.