BEA 80.0000.02 manual Bridge Rectifier, Title Request to Exit Manual Doors

Page 7

24V

TRANSFORMER

~ ~

BRIDGE

RECTIFIER

+ -

N/C

COM

DAY/ NIGHT SWITCH NORMALLY CLOSED FOR LOCK OPERATION

NORMALLY CLOSED DOOR POSITION SWITCH

MAGLOCK

NOTES: 1) USE COMMON NORMALLY/ OPEN CONTACTS FOR ELECTRIC PANIC AND STRIKES

IF AFTER TROUBLESHOOTING A PROBLEM, A SATISFACTORY SOLUTION CANNOT BE ACHIEVED, PLEASE CALL B.E.A., INC. FOR FURTHER ASSISTANCE DURING EASTERN STANDARD TIME AT 1-800-523-2462 FROM 8AM - 5PM. FOR AFTER-HOURS, CALL EAST COAST: 1-866-836-1863 OR 1-800-407-4545 / MID-WEST: 1-888-308-8843 / WEST COAST: 1-888-419-2564. DO NOT LEAVE ANY PROBLEM UNRESOLVED. IF YOU MUST WAIT FOR THE FOLLOWING WORKDAY TO CALL B.E.A., LEAVE THE DOOR INOPERABLE UNTIL SATISFACTORY REPAIRS CAN BE MADE. NEVER SACRIFICE THE SAFE OPERATION OF THE AUTOMATIC DOOR OR GATE FOR AN INCOMPLETE SOLUTION.WEB: WWW.BEASENSORS.COM

100 ENTERPRISE DRIVE PITTSBURGH, PA 15275 PHONE: (412) 249-4100 FAX: (412) 249-4101 EMAIL: www.beasensors.com

TITLE: REQUEST TO EXIT MANUAL DOORS

SIZE:

DRAWN BY:

REV BY:

PART NO:

80.0028.02

A

KJG

KJG

 

 

 

 

 

SCALE:

DATE:

SHEET

 

 

NONE

28 MAY 2005

1 OF 1

 

 

 

 

 

 

Image 7
Contents Transformer Title ON/ OFF/ Hold Open SwitchWiring Diagram Eagle Control24 VAC Title Sliding Door Lock with Wizards DC only Xfrmr Title Prision Door Release Maglock #1Operator Transformer BodyguardTitle Request to Exit Manual Doors Bridge RectifierTransformer Door Control Eagle Bodyguard Bodyguard Transformer LO21P White