Motorola 660AV manual Troubleshooting Symptom Charts/Peripheral

Page 32

 

 

Troubleshooting

 

Symptom Charts/Peripheral (Continued) - 14

 

 

 

Peripheral (Continued)

 

 

 

 

Cannot double-click

1

Remove duplicate System files from

to open application,

2

hard drive.

disk, or server

3

Clear parameter RAM. Hold down <Command> <Option> <P>

 

 

 

 

<R> during startup but before “Welcome to Macintosh”

 

 

 

4

appears.

 

 

 

If mouse was connected to keyboard, connect mouse to

 

 

 

 

computer ADB port instead. If mouse works, replace

 

 

 

5

keyboard or ADB cable.

 

 

 

If mouse does not work in any ADB port on computer, replace

 

 

 

6

mouse.

 

 

 

Replace logic board. Retain customer’s SIMMs.

No response to any

1

Check keyboard connection to ADB port.

key on keyboard

2

Replace keyboard cable.

 

 

 

3

Replace keyboard.

 

 

 

4

Replace logic board. Retain customer’s SIMMs.

Image 32
Contents Centris 660AV/Quadra 660AV Basics Overview Figure Centris 660AV and Quadra 660AVSpecifications Processors Digital Signal Memory Vram Disk Storage CD-ROMInterfaces Expansion SlotEthernet Audio Devices KeyboardSound and Video Sound GeneratorLine Voltage Frequency Power ElectricalPhysical Environmental Troubleshooting General Symptom Charts Error ChordsSystem System Floppy Drive Floppy Drive Floppy Drive Video Video Hard Drive Troubleshooting Symptom Charts/Hard Drive CD-ROM drive Peripheral Troubleshooting Symptom Charts/Peripheral Peripheral Miscellaneous Take Apart Top Cover Power Supply Power Supply Take Apart Power Supply Take Apart Take Apart Power Supply Remove the CD-ROM Drive EMI shield Tab Main Power Supply Power Switch Logic Board Take Apart Logic Board Floppy Speaker Drive Cable Disconnect these cables CD-ROM Drive EMI Shield Hard Drive EMI Shield Tab Take Apart Logic Board Slide the logic board Replacement Note Slide Floppy Drive Take Apart Take Apart Floppy Drive Hard Drive Take Apart Hard Drive Take Apart Hard Drive Remove the hard drive EMI shield Tab CD-ROM Drive Power Cable Scsi Data Cable Take Apart CD-ROM Drive Remove the CD-ROM Drive EMI shield Replacement Note Be sure Internal Chassis and Speaker Two rail and tab sets at Page Cable and the LED cable Remove the two torx Bottom Cover Internal Chassis Metal Tab Rail Replacement Note After Bottom Cover Actuator Replacement Note Take Apart Bottom Cover Upgrades Expansion Cards Upgrades Expansion Cards Loosely connect Adapter Card Tab Connector Bottom Case Slot Expansion Slot Upgrades Expansion Cards Attach the thumbscrews Upgrade Slotted CD-ROM Drive Bezel Drive Bay Shield Upgrades CD-ROM Drive Upgrade Push in the CD-ROM Align the slots at Connect these cables Power Mac Upgrade Additional Procedures Battery VerificationPositive Probe Negative Probe Replacement Page Page Exploded View Exploded View