The Remote Site
4.2Environment
It is recommended to take some security measures for the site to prevent tampering with the equipment (for example a locked cabinet).
The ambient temperature around the equipment must be within 0 – 45 ºC. The relative humidity must be within 5% - 95%, non condensing.
4.3Configuring the CPE Modem
The CPE Modem must be configured to map the VLANs used by the IP DSLAM to PVCs towards the Central Office (see Figure 4 on page 8). It must be configured to use the PVCs (VPI, VCI) used by the Central Office DSLAM, and the Management and Data VLAN IDs used by the IP DSLAM.
|
|
|
| Central |
|
|
|
| Office |
| Management VLAN | VPI / VCI | Management PVC | DSLAM |
VLAN ID | VLAN ID |
| ||
| VPI / VCI | |||
|
|
| ||
VLAN ID | VLAN ID |
|
| |
|
| VPI / VCI | ||
| Data VLAN | VPI / VCI |
| |
| Data PVC |
| ||
|
|
|
Figure 4 Configuration of the CPI Modem
Note: The Management VLAN ID does not necessarily have to be the same VLAN ID as the ID used in the EDA network (although it is recommended to use it to avoid confusion).
8 |