The CML12SXXX board is fully tested and operational before shipping. If it fails to function properly, inspect the board for obvious physical damage first. Ensure that all IC devices in sockets are properly seated. Verify the communications setup as described under GETTING STARTED and see the Tips and Suggestions sections following for more information.

The most common problems are improperly configured communications parameters, and attempting to use the wrong COM port.

1.Verify that your communications port is working by substituting a known good serial device or by doing a loop back diagnostic.

2.Verify option jumpers JP1 is installed and MODC is open / idle.

3.Verify Autostart is not enabled. Apply a ground level to the XIRQ signal on the BUS_PORT and press the Reset switch. If the monitor prompts, erase the internal EEprom by performing a BULK command or disable the Autostart by following the procedure in the Autostart chapter.

4.Verify the power source. You should measure a minimum of 9 volts between the GND and +VIN connections on the TB1 power connector with the standard power supply provided.

5.If no voltage is found, verify the wall plug connections to 115VAC outlet and the power connector.

6.Verify the logic power source. You should measure +5 volts between the GND and +5V connections on the TB1 power connector. If the +VIN supply is good and this supply is not +5V, immediately disconnect power from the board. Contact support@axman.com by email for instructions and provide board name and problem.

7.Disconnect all external connections to the board except for COM1 to the PC and the wall plug.

8.Make sure that the RESET line is not being held low.

Check for this by measuring the RESET Signal on the BUS_PORT.

9.Verify the presence of a 4MHz square wave at the EXTAL pin or 8MHz E clock signal if possible.

10.Contact support@axman.com by email for further assistance. Provide board name and describe problem.

21

Image 21
Contents CML12S-DP256 Contents Getting Started Board Startup Installing the SoftwareSupport Software Modc = Out, JP2 = do not care, see COM PortsTutorial Software DevelopmentCreating Source Code AS12 HELLO.ASM -L Hello Assembling source codeRunning your application Auto Programming HCS12 Flash EEpromMON12 operation notes MON12 OperationMon12 Monitor Commands MON12 Interrupt SupportMovw #IRQSRV,VIRQ MON12 and Noice Memory Map Noice OperationBDM Operation AutostartClock frequency = 24MHz ECS MemenAuto OFF / spare ModcMode OscselTB1 and J1 Power Ports and ConnectorsJP1 and JP2 CUT-AWAY Options 1Analog Port McuportKeypad / Port H BusportPCOM1 and PCOM2 6 connected and 7,8 connectedPCOM2 pin connections Can PortCAN-H CAN-LLcdport Connector P1 P4 HCS12 Header RingLcdport Test Points BDM PortSee the HC12 Technical Reference Manual for complete Documentation of the BDMTroubleshooting Tips and Suggestions LCD Command and Character Codes CommandCode Delay MON12 Interrupt Table