Multitech MTPRI-HD30B manual T1 DIP Switch 5 thru 8 Configuration

Page 13

 

 

 

 

1 Introduction

 

 

 

 

enabled

 

 

5

Equalization Control 4.

Refer to the following

Refer to the following listing

 

 

 

See Note 1

listing

 

 

6

Equalization Control 3.

Refer to the following

Refer to the following listing

 

 

 

See Note 2

listing

 

 

7

Equalization Control 2.

Refer to the following

Refer to the following listing

 

 

 

See Note 2

listing

 

 

8

Equalization Control 1.

Refer to the following

Refer to the following listing

 

 

 

See Note 2

listing

 

 

Note 1: Used with DIP-Switches 6 thru 8 for pulse equalization, line build-out (LBO), and equalizer gain limit settings.

Note 2: Used with DIP-Switches 5,7,8 for pulse equalization, line build-out (LBO), and equalizer gain limit settings.

T1 DIP Switch 5 thru 8 Configuration

 

DIP#5

DIP#6

DIP#7

DIP#81

Function

Tx Level

Cable

RcvLevel

0

0

0

0

T1

Long Haul

0.0 dB

100TP

36 dB

0

0

1

0

T1

Long Haul

-7.5 dB

100TP

36 dB

0

1

0

0

T1 Long Haul

-15 dB

100TP

36 dB

0

1

1

0

T1

Long Haul

-22.5 dB

100TP

36 dB

0

0

0

1

T1

Long Haul

0.0 dB

100TP

26 dB

0

0

1

1

T1

Long Haul

-7.5 dB

100TP

26 dB

0

1

0

1

T1 Long Haul

-15 dB

100TP

26 dB

0

1

1

1

T1

Long Haul

-22.5 dB

100TP

36 dB

1

1

1

1

T1

Short

533-655ft/

100TP

36 dB

 

 

 

 

 

Haul

2.4dB

 

 

 

Note 1: DIP Switch #8 sets the receive equalizer gain (EGL) during T1 long haul operations.

Note 2: applicable when enabled.

E1 DIP Switch 5 thru 8 Configuration

DIP#5

DIP#6

DIP#7

DIP#8

Function

Tx Level

Cable

RcvLevel

1

0

0

0

E1 Short Haul

ITU Rec G.703

120TP/

12 dB

1

0

0

1

E1 Long Haul

0.0 dB

75Coax

43 dB

100TP

1

0

1

0

E1 Long Haul

0.0 dB

100TP/

43 dB

 

 

 

 

 

 

75Coax

 

CommPlete Communications Server

5

Image 13
Contents PRI Card MTPRI-HD23B MTPRI-HD30B User Guide CommPlete Communications Server CommPlete Communications Server RJ48C Canadian Limitations NoticeRinger Equivalence Number CommPlete Communications Server Table of Contents Viii Introduction Introduction FeaturesProduct Description Status LEDsYellow Alarm RED AlarmSystem Error Physical LinkCard Components Position DIP SwitchT1 DIP Switch 5 thru 8 Configuration CPU Technical SpecificationsIsdn RJ-48C Installation Pre-Installation Notes Safety WarningsInstallation Procedure PRI Card User Guide Solving Problems Run Time LED Status Indicators General Troubleshooting ProcessStartup Self Test LED Patterns Problems involving Heart Beat