Soundstream Technologies REFERENCE 405 owner manual Protection Circuits, Service, Specifications

Page 7

8. PROTECTION CIRCUITS

Your REFERENCE405 amplifier is protected against both overheating and short circuits by means of the following circuits:

0 Main power supply fuses (2 at 20 amps each)

0Smart Power Supply Thermal Rollback activating at 85OC.

0A fail-safe thermal protection circuit activating at 95OC.

0Speaker over-current protection relays (on the 4 x 25 watt channels).

Your amplifier also incorporates an innovative Fault Diagnosis system that identifies a blown power supply fuse.

0If you experience blown main power fuses, DO NOT increase values beyond 20 amp (each) fuses.

10. SERVICE

Your Soundstream amplifier is protected by a limited warranty. Please read the enclosed warranty card.

11. SPECIFICATIONS

POWER OUTPUT

25 watts x 4 plus 100 watts x 1 (4 ohms, 12 V)

50 watts x 1 (4 ohms, 12 V, High Current)

40 watts x 4 plus 120 watts x 1 (4 ohms, 14.4 V) 200 watts x 1 (2 ohms)

>240 watts x 1 (1 or l/2 ohm)

9. TROUBLESHOOTING

PROBLEM

No sound and LEDs are not lit

Fault LED is lit

Repeatedly blown amp fuse, frequent activation of Smart

Power Supply Circuit or

speaker protection circuit breakers

no sound from subwoofer channel with 2 or 4 channels of input

no sound from channels

3 & 4 with 2 channels of input

CAUSE

0no power or ground at

amp

0no remote turn-on signal

0blown fuse near battery

0amp power supply fuse is blown

0check speaker configuration, amp may be in “High Power”mode, put amp into “High Current” mode if speaker load is less than 2 Ohms (see

Section 2, Selecting Operating Modes)

0speaker or leads may be shorted

0verify adequate amplifier ventilation

0check input settings on bottom of amplifier--switch should be set at inputs “I, 2, 3 or 4” unless using external inputs

check input settings on bottom of amplifier--switch should be set at inputs “1

&2”

0 THD: ~0.1%

0 Signal to Noise: >lOO dB

0Frequency Response: 20 Hz to 20 kHz +/- 0.5 dB

(dedicated sub channel): 20 Hz to 400 Hz +/- 0.5 dB

0 Bandwidth: 15 Hz to 50 kHz (dedicated sub channel): 15 Hz to 1 kHz

0Stereo Separation: >90 dB

0Damping: >200

0Input Sensitivity: 100 mV - 2.5 V a Input Impedance: 12 k ohms

Crossover Specifications:

0High Pass: 12 dB/octave, Continuously Variable from 60 - 240 Hz (front & rear)

0Low Pass: 24 dB/octave, Continuously Variable from 30 - 120 Hz

Dimensions: 16” W x 9-l/2” D x 2-l/4” H

11

12

Image 7
Contents SOUNDSTREAM@ Congratulations Design FeaturesSfERmJ~hmo SmEo~,Mmo STEFEo~jhmMounting of the Amplifier InstallationPlan the Installation Location of the AmplifierSoundstream Power40 Power80 Power40 or Power80 Or 8 ga Gas ~ 5. WiringLevel Setting Crossover AdjustmentsProtection Circuits ServiceSpecifications TroubleshootingSoundstream Technologies Speaker Wiring Configurations