SAFETY CHECK-OUT
After correcting the original service problem, perform the follow- ing safety checks before releasing the set to the customer:
Check the antenna terminals, metal trim, “metallized” knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below.
LEAKAGE
The AC leakage from any exposed metal part to earth Ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microampers). Leak- age current can be measured by any one of three methods.
1.A commercial leakage tester, such as the Simpson 229 or RCA
2.A
3.Measuring the voltage drop across a resistor by means of a VOM or
To Exposed Metal
Parts on Set
AC
0.15∝F 1.5kΩ voltmeter
(0.75V)
Earth Ground
Fig. A. Using an AC voltmeter to check AC leakage.
COMPONENTS IDENTIFIED BY MARK !OR DOTTED LINE WITH MARK !ON THE SCHEMATIC DIAGRAMS AND IN
THE PARTS LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT À LA SÉCURITÉ!!
LES COMPOSANTS IDENTIFIÉS PAR UNE MARQUE !SUR
LES DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE REMPLACER CES COMPOSANTS QUE PAR DES PIÈCES SONY DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU DANS LES SUPPLÉMENTS PUBLIÉS PAR SONY.
| TABLE OF CONTENTS |
|
1. GENERAL | 3 | |
2. ELECTRICAL ADJUSTMENT | 5 | |
3. DIAGRAMS |
| |
5 | ||
6 | ||
7 | ||
8 | ||
9 | ||
10 | ||
Printed Wiring Board – Power Section | 11 | |
4. EXPLODED VIEWS |
| |
Top Plate and Back Panel Section | 12 | |
Front Panel Section | 12 | |
Bottom Plate Section | 13 | |
5. ELECTRICAL PARTS LIST | 14 |
MODEL IDENTIFICATION
— BACK PANEL —
Parts No.
PARTS No. | MODEL |
US , CND | |
AEP, UK, E, AUS | |
|
|
• Abbreviation
CND : Canadian model
AUS : Australian model
2