National Instruments NI UES-3880 manual DIN-rail Mounting, Wall Mounting optional

Page 5

DIN-rail Mounting

The aluminum DIN-rail attachment plate should already be fixed to the back panel of the switch when you take it out of the box. If you need to reattach the DIN-rail attachment plate, make sure the stiff metal spring is situated towards the top, as shown in the figures below.

STEP 1:

Insert the top of the DIN-rail into the slot just below the stiff metal spring.

metal spring

STEP 2:

The DIN-rail attachment unit will snap into place as shown below.

metal spring

DIN-Rail

DIN-Rail

 

To remove the switch from the DIN-rail, simply reverse Steps 1 and 2 above.

Wall Mounting (optional)

For some applications, you will find it convenient to mount the NI UES-3880 on the wall, as illustrated below.

STEP 1:

Remove the aluminum DIN-rail attachment plate from the NI UES-3880’s rear panel, and then attach the wall mount plates, as shown in the diagram below.

top plate

bottom plate

STEP 2:

 

 

6.0 mm

Mounting the NI UES-3880 on the wall requires 4 screws.

 

 

Use the switch, with wall mount plates attached, as a guide

 

 

 

 

 

 

 

 

 

 

 

 

to mark the correct locations of the 4 screws. The heads of

 

 

 

 

 

 

the screws should be less than 6.0 mm in diameter, and the

 

 

 

 

 

 

shafts should be less than 3.5 mm in diameter, as shown in

3.5 mm

the figure at the right.

 

 

 

 

 

 

NOTE Before tightening the screws into the wall, make sure the screw head and shank size are suitable by inserting the screw into one of the keyhole-shaped apertures of the Wall Mounting Plates.

Do not screw the screws in all the way—leave about 2 mm to allow room for sliding the wall mount panel between the wall and the screws.

— 4 —

Image 5
Contents NI UES-3880 Overview Package ChecklistFeatures Panel Layout Mounting Dimensions unit = mm Wall Mounting optional DIN-rail MountingSafety First Wiring RequirementsWiring the Redundant Power Inputs Grounding the SwitchWiring the Alarm Contact 10/100BaseTX Ethernet Port Connection DIP Switch Settings Redundant Power InputsAlarm Contact Dual Speed Functionality and Switching LED IndicatorsSwitching, Filtering, and Forwarding Auto MDI/MDI-X ConnectionAuto-Negotiation and Speed Sensing Switching and Address LearningPower SpecificationsTechnology InterfaceTechnical Support and Professional Services Worldwide Offices Worldwide Technical Support and Product InformationNational Instruments Corporate Headquarters