Dell T310 owner manual Installing a Processor, 129

Page 129

12Carefully, lift the processor out of the socket and leave the release lever up so that the socket is ready for the new processor.

13After removing the processor, place it in an antistatic container for reuse, return, or temporary storage.

NOTE: Do not touch the bottom of the processor. Touch only the side edges of the processor. If you are permanently removing the processor, you must install a processor blank and a heat-sink blank in the CPU socket to ensure proper system cooling.

14Adding the blank is similar to installing a processor. See "Installing a Processor" on page 129.

Installing a Processor

1Unpack the new processor.

2Align the processor with the socket keys on the ZIF socket. See Figure 3-23.

3Install the processor in the socket.

CAUTION: Positioning the processor incorrectly can permanently damage the system board or the processor. Be careful not to bend the pins in the socket.

4With the release lever on the processor socket in the open position,

align the processor with the socket keys and set the processor lightly in the socket.

CAUTION: Do not use force to seat the processor. When the processor is positioned correctly, it engages easily into the socket.

5Close the processor shield.

6Rotate the socket release lever down until it snaps into place.

7Using a clean lint-free cloth, remove the thermal grease from the heat sink.

8Open the grease packet included with your processor kit and apply thermal grease evenly to the top of the new processor.

9Place the heat sink on the processor. See Figure 3-23.

10Using a #2 Phillips screwdriver, tighten the heat-sink retention screws. See Figure 3-22.

11Replace the cooling shroud. See "Installing the Cooling Shroud" on page 89.

12Replace the expansion card stabilizer. See "Installing the Expansion Card Stabilizer" on page 87.

Installing System Components

129

Image 129
Contents Dell PowerEdge T310 Systems July Contents Power Management Screen Processor Settings ScreenUefi Boot Settings Screen Other Information You May NeedEntering the iDRAC Configuration Utility Entering the BMC Setup ModuleRemoving the Front Bezel Installing the Front Bezel Removing the Expansion Card Stabilizer ContentsInstalling a Hot-Swap Hard Drive Into a Removing the Cooling Shroud Installing the Cooling ShroudInstalling an Optical or Tape Drive Removing a Redundant Power SupplyReplacing the System Battery 130 General Memory Module InstallationRemoving the RAID Battery 132 108Troubleshooting a Wet System 150 Contents 134136 154 When to Use the Embedded System Diagnostics161 166169 170177 Accessing System Features During Startup Front-Panel Features and Indicators Displays an error code followed by Information, and system error messagesBeen powered on Power-on indicatorLCD Panel Features Optional Home Screen To enter Bios Progress modeSelect RightSetup Menu View Menu Hard-Drive Indicator Patterns Back-Panel Features and Indicators Rebuild abortedSeconds, and off six seconds Redundant power supply 400 W Redundant power supplyVideo connector Serial connectorNIC Indicator Codes Guidelines for Connecting External DevicesPower Indicator Codes Diagnostic Lights Optional Bios checksum failure Diagnostic Indicator Codes CausesInstalled in your system Information onlyLCD Status Messages Removing LCD Status Messages Viewing Status MessagesRange. Power DisabledBattery Check Battery E1211Fault. Power E122C CPU PowerE122A E122D MemoryCPU or Bios CPU configur- unsupportedError. Power Parity errorE1610 Power Supply Check errorCheck power Supply E1614 Power Supply Error. Check Power supply E1618 PredictiveE1626 Power Supply E1624 Lost powerE1629 Power ConfigError. Review Error on BusE1711 PCI parity ## Device ##E1716 Chipset Ierr E1715 Fatal I/OBus ## Dev ## E1717Configuratio Fault. ReviewConfigured E1810 Hard drive ##E2016 Interrupt Controller failure Power cycle AC E2013 Bios unableE2017 Timer refresh Timer errorE201A SuperIO E2019 Parity errorE201B Keyboard E201CDuring Post Check screen Message E2023 Bios unable ConfigurError on Dimm E201E Post memoryE2111 SBE log Disabled onDimm ## Reseat DimmSystem Messages Alert! Power RebootingFatal error BootNvramclr jumper is installed on system board Mode detectedCPU x installed Attempt FailedBootable media is Current boot modeCorrect Connectors Gate A20 failure Is set to UefiPlease run Setup ConfigurationAccessible USB Disabled. IfCount exceeded Maximum rankFollowing Dimm has beenMemory set to No boot deviceMemory tests Terminated byNo timer tick No boot sector onInterrupt PCI Bios failed To installQuad rank Dimm Read fault Requested sector not foundDetected after Single rank orSector not found Seek errorSeek operation Shutdown failureMatch DIMMs shouldFollowing DIMMs should Match in size Time-of-dayTimer chip Setup programWill now reset Time-of-day notProtected mode System ServicesUnable to launch Image. SystemSystem reset Error has causedInstalled Code updateMemory Configuration Configuration isDegraded. CPU Not optimalWrite fault Diagnostics MessagesWrite fault on Selected driveOther Information You May Need Alert MessagesAbout Your System Choosing the System Boot Mode Using the System Setup Program and Uefi Boot ManagerResponding to Error Messages Entering the System Setup ProgramUsing the System Setup Program Navigation Keys System if any changes were madeMain Screen System Setup OptionsSpecify related features and options. See Serial Option Description Sata SettingsPower Management Fans, and memory modules with preconfigured orOption Description Report Keyboard Errors Memory Settings ScreenPOST. Any critical errors will be displayed To the systemSata Settings Screen Processor Settings ScreenBoot Settings Screen Integrated Devices Screen Serial Communication Screen PCI IRQ Assignment ScreenSelect an IRQ value at system startup Option Description Serial CommunicationEmbedded Server Management Screen Optional Power Management ScreenSystem Security Screen Enables or disables the NMI feature Exit Screen Entering the Uefi Boot ManagerUefi Boot Manager Screen Using the Uefi Boot Manager Navigation KeysSystem and Setup Password Features Uefi Boot Settings ScreenSystem Utilities Screen Using the System Password Using the System Setup Program and Uefi Boot Manager Repeat to step Using the Setup PasswordEmbedded System Management Baseboard Management Controller Configuration Entering the BMC Setup ModuleTry again Entering the iDRAC Configuration Utility IDRAC Configuration UtilityUsing the System Setup Program and Uefi Boot Manager Installing System Components Recommended ToolsInside the System Page Tab slots Installing System Components Front BezelRemoving the Front Bezel Insert tab Installing System Components Installing the Front BezelFront Bezel Inserts Removing the Front Bezel InsertInstalling the Front Bezel Insert EMI Filler PanelRemoving an EMI Filler Panel Removing and Installing an EMI Filler Panel EMI filler panel Installing an EMI Filler PanelOpening the System Opening and Closing the SystemSystem cover Chassis slots Closing the SystemInstalling the Expansion Card Stabilizer Expansion Card StabilizerRemoving the Expansion Card Stabilizer Removing the Cooling Shroud Cooling ShroudRemoving and Installing the Cooling Shroud Cooling shroud Installing the Cooling ShroudRemoving a Hard-Drive Blank Hard DrivesSee Figure Remove the front bezel. See Removing the Front Bezel onRemoving a Hot-Swap Hard Drive Installing a Hard-Drive BlankPage Installing a Hot-Swap Hard Drive Removing a Hot-Swap Hard Drive From a Hard-Drive Carrier Removing a Cabled Hard Drive Installing a Hot-Swap Hard Drive Into a Drive CarrierHard-drive bracket Installing a Cabled Hard Drive Removing a Cabled Hard Drive From a Hard-Drive Bracket Tabs Installing System ComponentsRemoving an Optical or a Tape Drive Optical and Tape DrivesInstalling an Optical or Tape Drive 100Drive bay screw slots 101 Installing System Components Power Supplies Removing a Redundant Power Supply103 Velcro strap Installing a Redundant Power Supply105 Removing a Non-Redundant Power SupplyInstalling a Non-Redundant Power Supply System FanRemoving the System Fan Installing the System Fan 107System fan System Memory General Memory Module Installation Guidelines109 Mode-Specific Guidelines110 Memory Sockets ProcessorAvailable 111 Installing Memory ModulesInstalling System Components 113 Removing Memory ModulesExpansion Card Installation Guidelines Expansion Cards114 115 Installing an Expansion CardInstalling System Components 117 Removing an Expansion Card Installing an iDRAC6 Express Card IDRAC6 Express Card Optional119 Notch Removing an iDRAC6 Express Card OptionalInstalling an iDRAC6 Enterprise Card IDRAC6 Enterprise Card Optional121 IDRAC6 Enterprise card connector 123 Removing an iDRAC6 Enterprise CardVFlash Media Optional Installing a VFlash MediaInternal USB Memory Keys Removing a VFlash Media125 21. Removing or Installing a USB Memory Key USB memory keyRemoving a Processor Processor127 22. Installing and Removing the Heat Sink Heat sinkProcessor shield ZIF socket Socket key 128129 Installing a ProcessorSystem Battery Replacing the System BatterySystem battery is a 3.0-volt V, coin-cell battery 131 24. Replacing the System BatteryRemoving the RAID Battery RAID Battery OptionalBattery carrier Battery carrier tabs Installing a RAID BatteryRAID battery 133Removing the Chassis Intrusion Switch Chassis Intrusion SwitchInstalling the Chassis Intrusion Switch Intrusion connector on the system board135 Removing the Control Panel Assembly Control Panel Assembly137 Installing the Control Panel Assembly SAS BackplaneRemoving the SAS Backplane 139 Power Distribution Board Installing the SAS BackplaneRemoving the Power Distribution Board 141 System Board Replacing the Power Distribution BoardRemoving the System Board 142143 System board Installing the System Board145 146 147 Troubleshooting Your SystemTroubleshooting External Connections Troubleshooting the Video SubsystemTroubleshooting a USB Device Troubleshooting a Serial I/O Device Troubleshooting a NIC149 Troubleshooting a Wet System 151 Troubleshooting a Damaged System Troubleshooting the System Battery152 153 Troubleshooting Power SuppliesTroubleshooting a Fan Troubleshooting System Cooling Problems155 Troubleshooting System MemoryTroubleshooting Your System 157 Troubleshooting an Internal USB KeyTroubleshooting an Optical Drive 159 Troubleshooting a Tape Backup UnitTroubleshooting a Hard Drive 161 Troubleshooting a SAS or SAS RAID ControllerOpen the system. See Opening the System on 162 Troubleshooting Expansion Cards163 Troubleshooting the ProcessorTroubleshooting Your System Embedded System Diagnostics Features Using Online DiagnosticsRunning the System Diagnostics 165Running the Embedded System Diagnostics When to Use the Embedded System DiagnosticsUsing the Custom Test Options System Diagnostics Testing OptionsSelecting Devices for Testing Selecting Diagnostics OptionsViewing Information and Results Cycle pins System Board Jumpers169 170 System Board Connectors171 172 Hard drive connectors SAS Backplane Board ConnectorsSAS a connector Jumpers and Connectors Front BackPower Distribution Board Connectors Disabling a Forgotten PasswordJPWR1 connector JPWR2 connector 175 176 Contacting Dell 177Getting Help 178 Amperes AC Alternating current 179180 181 182 Mm Millimeters Ms Milliseconds 183184 System memory See RAM 185TCP/IP Transmission Control Protocol/Internet Protocol 186187 188 Using Dell PowerEdge Diagnostics 189Index 190 191 Post192 193 Wet system Uefi Boot Manager entering, 69 main screen194
Related manuals
Manual 73 pages 27.4 Kb

T310 specifications

The Dell PowerEdge T310 is a tower server designed to meet the needs of small businesses and remote offices looking for an efficient and reliable server solution. With its robust architecture and user-friendly features, the T310 provides a solid foundation for various applications, such as file sharing, data backup, and running virtual machines.

One of the standout features of the Dell T310 is its powerful processing capabilities. It is equipped with Intel Xeon processors, which deliver impressive performance and reliability. These processors are designed for multi-threaded applications and can handle intensive workloads, making the T310 suitable for demanding environments. The server supports up to two Intel Xeon processors, allowing businesses to scale their computing power as their needs grow.

Memory capacity is another key characteristic of the T310. It supports up to 32GB of DDR3 RAM, which is essential for running multiple applications simultaneously without any performance degradation. The memory can be expanded easily, allowing businesses to increase capacity as their data needs evolve.

Storage options on the T310 are flexible and extensive. The server features up to four hot-swappable 3.5-inch hard drive bays, supporting SATA and SAS drives. This allows for a maximum internal storage capacity of up to 8TB, giving businesses the space they need for data-intensive tasks. The hot-swappable design enhances uptime, enabling users to replace drives without shutting down the server.

In terms of connectivity, the Dell T310 is equipped with multiple USB ports, Ethernet ports, and optional expansion slots. It also supports various RAID configurations, ensuring data protection and redundancy. This flexibility makes it an excellent choice for organizations looking to maintain data integrity while maximizing performance.

Another notable aspect of the T310 is its energy efficiency. The server incorporates Dell’s energy-efficient technologies, helping businesses reduce their overall energy consumption and lower operational costs. The compact design of the T310 allows it to fit easily into standard office environments without taking up excessive space.

Overall, the Dell PowerEdge T310 stands out as a reliable and versatile tower server. Its combination of processing power, memory capacity, flexible storage options, and energy-efficient technologies make it a great choice for small to medium-sized businesses looking for a dependable server solution to support their critical applications and services.