Environmental
| NOTE: For information on supported expanded operating |
| temperature range and configurations, see support.dell.com/ |
| manuals. |
Storage | |
| gradation of 20 °C per hour |
Relative humidity |
|
Operating | 20% to 80% (noncondensing) at a maximum wet bulb |
| temperature of 29 °C (84.2 °F) |
Storage | 5% to 95% at a maximum wet bulb temperature of 38 °C (100.4 °F) |
Maximum vibration |
|
Operating | 0.26 Grms at 5 |
Storage | 1.87 Grms at 10 |
Maximum shock |
|
Operating | One shock pulse in the positive z axis (one pulse on each side of |
| the system) of 31 G for 2.6 ms in the operational orientation |
Storage | Six consecutively executed shock pulses in the positive and |
| negative x, y, and z axes (one pulse on each side of the system) |
| of 71 G for up to 2 ms |
| Six consecutively executed shock pulses in the positive and |
| negative x, y, and z axes (one pulse on each side of the system) |
| of 32 G faired square wave pulse with velocity change at 270 |
| inches/second (685 centimeters/second) |
Altitude |
|
Operating | |
| NOTE: For altitudes above 2950 ft, the maximum operating |
| temperature is derated 1ºF per 550 ft. |
Storage | |
Airborne Contaminant Level |
|
Class | G1 as defined by |
8