Compaq GS140 Memory Channel − Optional OpenVMS Systems, Memory Channel Controller/Network Hub

Page 12

....................................................................................................................................................................................................................................

.

QUICKSPECS

Compaq AlphaServer GS140

 

 

Options

Step 10 MEMORY CHANNEL Optional (continued)

OpenVMS Systems (continued)

In cases where nodes must be separated by a longer distance than standard copper cables allow, the CCMFB option converts the output of the standard CCMAB controller or CCMLB line card to single-mode fibre optic cable. The fibre optic connection may be up to 2,000 meters long between two CCMAB controllers connected in virtual hub mode, or 3,000 meters between a CCMAB controller and a CCMHB hub. (The connection from the CCMHB hub to a second system may also be 3,000 meters). The CCMFB option requires a second PCI slot in the system from which it draws power only. It is normally connected to the corresponding CCMAB controller with the short BN39B-01 cable. The CCMFB is also used in the CCMHB hub where it occupies a slot normally used by the CCMLB line card, limiting expansion to four radial fibre optic connections.

The CCMHB-BA hub expansion box provides additional slots for up to 8 fibre optic connections. Two standard length, single-mode fibre optic cables are available (BN34R-10 and BN34R-31); however, users normally provide this connection. Customers should reference the TIA/EIA 568-A Commercial Building Telecommunications Cabling Standard, Section 12.3.4. Fibre optic connectivity is completely transparent to the systems using it and has no performance impact.

MEMORY CHANNEL Controller/Network Hub

 

PCI System Area Network controller, maximum two

CCMAB-AA

System Area Network hub with 4 line cards; includes BN19P-2E power cord for Canada, Japan,

CCMHB-AA

and US operations; country-specific power cord for other regions is required

 

MEMORY CHANNEL hub expansion box with no line cards

CCMHB-BA

Expansion line card for CCMHB hub

CCMLB-AA

1-m cable for CCMAB and CCMHB

BN39B-01

4-m cable for CCMAB and CCMHB

BN39B-04

10-m cable for CCMAB and CCMHB

BN39B-10

Copper-to-single mode fibre optic converter

CCMFB-AA

TruCluster Production Server Software for Tru64 UNIX

QB-3RLAQ-AA

Tru64 UNIX Driver for MEMORY CHANNEL license

QB-4ZCAQ-AA

OpenVMS Cluster license for Alpha systems

QL-MUZAQ-AA

MEMORY CHANNEL Power Cords

 

Ireland, United Kingdom

BN19A-2E

Egypt, India

BN19S-2E

Central Europe

BN19C-2E

Israel

BN18L-2E

Switzerland

BN19E-2E

Italy

BN19M-2E

Denmark

BN19K-2E

Australia, New Zealand

BN19H-2E

MEMORY CHANNEL (Requirements for Currently Installed AlphaServer 8400 systems)

Console firmware at revision V2.3 or higher

CCMAA-BA adapter must be installed in slots 0-7 of a DWLPA-AA/AB/BA/BB PCI; no restriction for DWLPB-AA/AB/BA/BB PCI bus

For two system nodes, order one CCMAA-BA per system and one BC12N-10 cable to connect them.

For three or more system nodes, order CCMHA-AA (MEMORY CHANNEL Hub) one CCMAA-BA and one BC12N-10 cable per system node.

CCMHA-AA (MEMORY CHANNEL Hub) is configured with four CCMLA-AA Line Cards and supports up to four nodes. Expansion up to eight system nodes can be achieved by adding up to four additional CCMLA-AA Line Cards, except TruCluster Production Server configurations

PCI to MEMORY CHANNEL controller, maximum two

CCMAA-BA

MEMORY CHANNEL Hub with four line cards

CCMHA-AA

MEMORY CHANNEL Line Card for use with MEMORY CHANNEL Hub (CCMHA-AA)

CCMLA-AA

12DA-10051-00A-008 — 02.28.2000

Image 12
Contents CD-ROM with space for Optional diskette driveCabinet Control System Standard Features Service and Support Intelligent ManageabilitySecurity OS SupportSystems/Options − Select system− Additional CPU Modules SMP Expansion − Optional − Memory − OptionalOptions − I/O Expansion Buses − Optional− System I/O Modules − Optional − Storage Adapters/Controllers − OptionalKZPBA-CA KZPBA-CBKZPAC-AA KZPAC-CA− Storage Adapters/Controllers − − External Storage Controllers − OptionalScsi Signal Converter − Storage Devices − OptionalInternal Storage UltraSCSI StorageWorks Plug-in UnitsRAID Storage Solutions − Storage Devices − Optional UltraSCSI HubsBit Disk Drives Tape Drives− Storage Devices − Optional External Storage Devices SW5XX, SW6XX, SW8XX Storage Cabinets Scsi Disk Drives− Networks and Communications − Optional PCI LAN Communications Controllers− Memory Channel − Optional Tru64 Unix SystemsOpenVMS Systems Memory Channel Power Cords − Memory Channel − Optional OpenVMS SystemsMemory Channel Controller/Network Hub − Graphics Support for Tru64 Unix − Optional KFE72-EA− Tru64 Unix and OpenVMS Partitions − Optional Monitor Power Cords Unsupported Options for GS140 Partitions− Monitors − Optional Video Extension CableSN-LKQ47-AF SN-LKQ47-ATSN-LKQ47-AX SN-LKQ47-BT− Power Expansion Components − Optional Phase Expansion ComponentsExpansion Cabinet QA-MT4AA-H8 QA-MT4AA-GZ QA-6ADAA-H8 QA-6ADAA-GZ QB-5RXAQ-AA QL-MTJAQ-AA QL-MTKAQ-AAQL-MTFAQ-AA Tru64 Unix OpenVMSPowerware Plus 3-Phase UPS Models UPS Models 15 and 18 kVAUPS Models 24 and 36kVA 4N-AEAAN-BD 4N-AEAAP-BD 4N-AEAAN-BE 4N-AEAAP-BECabinets with 480V Input Transformer UPS Monitoring and Unattended Shutdown Software4N-AEAEO-DA 4N-AEAEO-DC 4N-AEAEO-DB 4N-AEAEO-DD 4N-JMIU4-AB Power Configuration Table Add PCI optionsAdd Eisa options Disk and Tape optionsUpgrades Upgrades − Technical InformationSMP Speed Upgrades In-Cabinet Upgrades In-cabinet CD-ROM In-Cabinet 3-phase Power ExpansionVAX/DEC 7000 to AlphaServer GS140 In-Cabinet SMP Upgrades AlphaServer GS140 SMP Expansion OptionsTechnical Specifications 25 DA-10051-00A-008