Acer STR7LAA001 Power specifications

Page 7

Acer AC100 Server Specifications

Power specifications

 

 

 

 

 

 

 

200 W Power Supply

 

 

 

 

 

 

 

Operational Input Voltage

100 to 240

 

 

 

 

 

Range (Vrms)

 

 

 

 

 

 

 

Frequency Range (Nominal)

50 / 60

 

 

 

 

 

 

(Hz)

 

 

 

 

 

 

 

Nominal Input Voltage (Vrms)

100

120

200

208

220

230

240

Max. Rated Output Wattage

200.83

200.85

200.87

200.83

200.65

200.65

200.643

Nominal Input Current (A

2.46

2.03

1.21

1.17

1.11

1.06

1.022

rms)

 

 

 

 

 

 

 

Max. Rated Input Wattage

245.37

242.45

237.64

237.34

236.99

236.65

236.389

Rating

 

 

 

 

 

 

 

Max. Rated VA (Volt-Amp)

246.35

244.16

242.98

242.93

243.82

244.72

245.472

Efficiency (%) at Max. Rated

81.85

82.84

84.53

84.62

84.67

84.79

84.880

Output Wattage

 

 

 

 

 

 

 

Power Factor

1.00

0.99

0.98

0.98

0.97

0.97

0.963

Leakage Current (mA)

0.26

0.30

0.56

0.57

0.57

0.61

0.620

Max. Inrush Current (A peak)

58.80

73.60

116.80

127.20

128.80

129.60

132.800

Max. Inrush Current Duration

0.90

0.90

0.75

0.77

0.77

0.77

0.768

(ms)

 

 

 

 

 

 

 

Max. British Thermal Unit

1912

1876

1836

1831

1832

1828

1835

Rating (BTU/hr)

 

 

 

 

 

 

 

7

Image 7
Contents What’s New Product OverviewRear view Front View Door OpenNetwork Controllers Deployment/ServiceabilityProcessors and Chipset MemoryChassis/Form Factor Power SupplyOperating Systems Input/output interfaceEnvironmental Specifications Onboard storage specifications Technical specifications PCIe specificationsOnboard LAN specifications Memory specifications and population Power specifications AC100 model options Acer server software utilitiesHard drives Available options ProcessorsTPM module Service and support