Initio INI-9100UW user manual Main menu options, Scan Bus, Device Setup

Page 40

Main menu options

The main menu provides five possible setup options for meeting your system configuration.

Scan Bus

Device Setup

Adapter Setup

BIOS Setup

Disk Utility

Scan Bus

This option scans the SCSI bus. All device ID’s are displayed on the screen including SCSI ID’s without devices attached. This allows for a better definition of location and priority on the SCSI bus.

A device ID should only be changed if it conflicts with another device address on the same bus. Refer to your peripheral documentation for changing SCSI ID’s.

The best ID for a bootable hard disk is SCSI ID 0.

Device Setup

All device ID’s for the INI-9100U/9100UW are displayed on screen, including SCSI ID’s without devices attached. This allows for a better definition of location and priority on the SCSI bus.

Asynchronous Transfer. Use this option to set the synchronous data transfer mode. The INI-9100U/9100UW host adapter will transfer data at a maximum rate of 5 MBytes per second in asynchronous mode and 20 MBytes per second in synchronous mode. The INI-9100UW host adapter will transfer data at a maximum rate of 10 Mbytes per second in asynchronous mode and 40 Mbytes per second in synchronous mode. Use this option to set the synchronous data transfer mode. The default setting for this option is for synchronous operation. (no)

4-3

Image 40
Contents Initio Initio Corporation Del Franco Street San Jose, CA VoiceCopyright TrademarksChanges Technical SupportREADME.TXT File IiiThis page Intentionally Left Blank Table of Contents Microsoft Windows 10-111-1 12-113-1 ViiViii Inside this manual IBM OS/2 Notational Conventions Convention DescriptionThis page Intentionally Left Blank Introduction Introduction Initio INI-9100U/9100UW host adapterApplication and peripheral support INI-9100U Host adapterPlug and Play installation Product featuresOnboard Bios Command QueuingProgrammable Scsi Auto-TerminationProduct specifications Where to get helpOperating Temperature Storage TemperaturePage This page Intentionally Left Blank Getting Started Host adapter and the Scsi bus Getting StartedScsi bus preparation Scsi bus termination Examples of Scsi bus terminationInstallation basics Scsi Devices Configuration Host Adapter TerminationInstalling the INI-9100U/9100UW host adapter and cabling Quick installation overviewUnpacking and inspection Configuring the host adapter Cable terminationPage Hardware Installation This Chapter Is About ∙ Installing the INI-9100U/9100UWIntroduction Hardware InstallationPreparing your Scsi device INI-9100UW Board Layout Power down the host computer and all peripherals Installation in ten easy stepsINI-9100U INI-9100UW Description Use static electricity discharge precautions Inserting the host adapterInstallation of internal Scsi cables Inserting the INI-9100U/9100UW into a PCI slotDrive activity LED Multiple InitiatorsInstallation of external Scsi cables Host computer configurationSmartSCSI Setup Utility System startupHard disk drive preparation Low-level formatHost Adapter Setup Host Adapter Setup When to use the SmartSCSI Setup UtilityRunning the SmartSCSI Setup Utility Press Ctrl I for SmartSCSI Setup UtilityMain menu options Device SetupScan Bus Page Page Host Adapter Setup Bios Setup Disk Utilities MS-DOS/Windows Installation MS-DOS Driver InstallationOverview Enter Type Dossetup Enter Continue Ctrl + ALT + DELDevice driver command line options Driver config optionsThis page Intentionally Left Blank Microsoft Windows Microsoft Windows 95 Driver Installation New Windows 95 installation Driver tab, then select Change Driver Select Initio INI-9100U/9100UW Host Adapter, select OK, then Adding the Initio Driver to an existing Windows 95 system Updating the Initio device driver Page Page Microsoft Windows-NT Microsoft Windows-NT Driver Installation OEMSETUP.INFNew Windows-NT installation Windows-NT Setup Enter Initio host adapter driver is now installed Page ∙ Type A\WINNT, select Continue Page Page Novell NetWare Novell NetWare Driver Installation \NETWARE\HAM\INI9100.DDINew NetWare 4.xx installation D\netware4.0\english\ EnterNovell 4.x Installation ∙ Type A\netware\v4x Press Enter Specify Initio Driver PathSelect the Initio Driver Adding the Initio driver to an existing NetWare system ∙ Type CD \ Nwserver Enter ∙ Type Server Enter∙ Select ini910U.DSK, press Enter Load Pathname ini910u Driver Config Option This page Intentionally Left Blank IBM OS/2 IBM OS/2 Driver Installation \OS2\INI910U.DDPNew OS/2 installation Edit CONFIG.SYS file Adding the Initio driver to an existing OS/2 systemSelect Destination Directory Add OS/2 Device DriverInstall Verbose Mode provides detail information about driver on This page Intentionally Left Blank SCO Unix SCO Unix Driver Installation 10-2Installing the Initio driver in a new SCO Unix system Updating interrupts and hardware settings10-3 10-4 Linking a package in SCO UnixAdding the Initio driver to an existing SCO Unix system ∙ Type i91u Enter 10-5Cd /etc/conf/cf.d Linkunix∙ Type i91u Enter 10-6∙ . /linkunix Enter Attach Number Lun10-7 11-8 SCO UnixWare SCO UnixWare Driver Installation 11-2Installing the Initio driver in a new UnixWare system 11-3Install Host Bus Adapter Drivers 11-4Install another HBA Diskette 11-5∙ cd /etc/conf/sdevice.d Adding the Initio driver to an existing UnixWare system11-6 Using multiple Host Adapters 11-7Removing the Initio driver from a UnixWare system Appendix Troubleshooting 12-2∙ Type go Enter 12-3DOS Space 1GB MS-DOS, OS/2 & Windows NTNetWare 12-4Drives with Multiple Operating Systems 12-5Page Glossary This Chapter Is About ∙ Common terms and definitionsDefinitions of Terms 13-213-3 Product Warranty FCC Compliance StatementClass B Equipment Information to User 13-4EN 55 9100UW2 Declaration of Conformance Declaration of the Manufacturer/Importer13-5

INI-9100UW, INI-9100U specifications

The Initio INI-9100UW and INI-9100U are high-performance SCSI (Small Computer System Interface) controllers designed to provide exceptional data transfer rates and efficient connectivity for various storage solutions. These controllers are particularly favored in environments that demand reliable and fast data access, including servers and workstations.

One of the standout features of the INI-9100 series is its ability to support ultra-wide SCSI, allowing for data transfer rates of up to 40 MB/s. This speed is crucial for applications requiring rapid data movement, such as databases, streaming applications, and intensive computing tasks. The INI-9100UW variant extends this capability with its support for 68-pin connectors, which further enhances data throughput by allowing for a greater number of devices to be connected simultaneously.

Both the INI-9100UW and INI-9100U are built on a robust architecture, which includes integrated support for a wide range of SCSI devices. This includes hard disk drives, CD-ROMs, and tape drives, making these controllers versatile solutions for both modern and legacy systems. Their compatibility with various operating systems, including Windows and Linux, ensures seamless integration into existing setups.

Furthermore, the Initio controllers employ advanced technologies such as asynchronous transfers and cycle stealing, which minimize CPU load and allow the system to handle multiple tasks simultaneously without bottlenecks. This makes them particularly advantageous in multitasking environments.

Another key characteristic of the INI-9100 series is their dedicated onboard BIOS, which simplifies device management and setup processes. Users can easily configure the controllers for optimal performance using the user-friendly interface provided by the BIOS.

In summary, the Initio INI-9100UW and INI-9100U are powerful SCSI controllers that offer high-speed data transfer capabilities, robust architecture, and versatile compatibility with various SCSI devices. Their advanced technologies and user-friendly features make them ideal solutions for environments requiring reliable and efficient data access. As data storage needs continue to evolve, the INI-9100 series remains a valuable asset for both enterprise-level and individual users seeking to enhance their storage solutions.