Gossen IPP 144 - 40 GE user manual USER`S Manual

Page 1

USER`S MANUAL

Thermal Graphics Printers

IPP 144 - 40 G

IPP 144 - 40 GE

Paper Reroll Mechanism

IPP - AW

Image 1
Contents USER`S Manual Qualified Personnel Safety instructions ENTable of Contents Index KEY ResetIPP 144 40 G / IPP 144 40 GE General FeaturesModel Supply Voltage Review of the model typesPage Basic Version Technical DataPrint mechanism Paper EMC AWG Connections MiscellaneousVersion E Design Design and InstallationConnection InstallationPin assignments Pin AssignmentGND GND Serial Interface II only IPP 144 -40 GETXD DTRInterface selection Interface Interface Set slider switch S 101 to the right hand side Connecting diagramRS 232 C Current loop Set slider switch S 101to the left hand sideSender passive IPP 144 40 G active USB RS 232 C RS 485 Option ProfiBusOperation „AlarmOperating Controls Line FeedPage Replacing the Paper Roll Entering the menu program Print current parameters Menu Program„ACTUAL Parametrs ? Press „ENTER „CHANGE Parameters ?„ACTUAL Parameters ? Menu program „Change Parameters Quitting the menu program„END Example Changing parametersNo ? 300General Functions AdjustmentCyrillic Print graphics Serial InterfacesDirectly from DetailsSET Calendar Date / Time only E-version„SELECT YES ? „ENTER SET Calendar Time SettingSET Time Date / Time Output E Version Set Summer Winter Time ModeChange Time W-S Serial protocol Print date/time „always Print date/ time with a received control commandPrint Date / Time Headline Print Date / TimeStart Printing Functional DescriptionAddressing Protocol & Text Handshake MessagesXON Print interval serialXoff Version E IPP 144 40 GE 7.4.1.Text Entry Temperature 263,45 C Calling via serial interface Text OutputImportant notes Menu program / Complete Selection AppendixSET Time Character set various languages Character Sets Control Character used for Data TransmissionGeneral purpose characters Additional characters used by the printerPage Character set Ascii and cyrillic Print Character Commands Command GS ! n Command ESC n CodeSpecifies / clears underline Specifies character sizeDownload Specifies Command ESC %n ClearsCharacter set Specifies Command ESC $ nL nH Absolute Print Position CommandsSets horizontal tab position Command ESC D n1 nk Null PositionPrints column bitmap image Command ESC *m nL nH d1 dk Bitmap image CommandsMSB LSB Prints raster Command ESC A* nL nH d1 dk bitmap image Code8+1 8+2 8+3 2n/8+1 2n/8+2 2n/8+3 3n/8 NL+nHx256xn/8 Print Command GS / m download Bitmap image Code Command ESC Line Feed CommandsCommand ESC 3n Code Sets initial line feed Sets line feedSets width Command GS w n Barcode Barcode CommandsPrints barcode Command GS k m d1 dk NULL/GS k m n d1 dnCODE128 Page DPM...MF SUB DAAPrint-out, with time & date, marks and weights Examples for Automatic text Insert modeII Paper reroll mechanism IPP AW General information FrontRear Less = turn left More = turn right Inserting the paper Removing the paperIII Accessories Gossen Müller & Weigert

IPP 144 - 40 G, IPP 144 - 40 GE specifications

The Gossen IPP 144 - 40 GE and IPP 144 - 40 G are advanced portable light meters renowned for their precision and reliability in various lighting conditions. These instruments cater to professional photographers, videographers, and lighting designers seeking accurate light measurements to ensure optimal exposure in their work.

One of the standout features of the Gossen IPP 144 series is its dual measurement capability. The IPP 144 - 40 GE offers both incident and reflected light measurement, allowing users to evaluate light conditions from different perspectives. This flexibility enhances its usability in diverse environments, whether it be for capturing studio portraits or outdoor landscapes.

The device features a large, bright LCD display that ensures clear visibility of readings in any lighting situation. The easy-to-navigate menu allows users to access functions efficiently, streamlining the workflow. The robust construction of the meter guarantees durability, making it suitable for fieldwork and everyday use.

Equipped with sophisticated photo sensors, the Gossen IPP 144 meters are capable of providing highly accurate measurements in both artificial and natural lighting conditions. The range of measurement goes from very low light levels to bright daylight, accommodating a wide variety of scenarios. This adaptability is particularly useful for professionals working across different genres of photography and video production.

Another significant characteristic of the IPP 144 - 40 GE and IPP 144 - 40 G is the built-in memory function. This feature allows users to save specific readings for later analysis, enabling them to compare different lighting setups or conditions. With this capability, photographers can make informed decisions about adjustments to achieve desired aesthetic results.

Additionally, the meters come equipped with a calibration function, ensuring long-term reliability and accuracy. Regular calibration against known standards guarantees that users can depend on the readings delivered by these light meters.

Overall, the Gossen IPP 144 - 40 GE and IPP 144 - 40 G stand out with their combination of advanced measurement capabilities, durable design, and user-friendly interface. They are indispensable tools for professionals who demand precision and versatility in their light measurement equipment, ensuring their creative visions can be realized with confidence in any lighting environment.