Furman Sound PS-PRO II manual Service, Ce, Nrtl-C

Page 11

PS - PRO II - POWER CONDITIONER / sequencer

liability or otherwise. Under no circumstances, whether based on this Limited Warranty or otherwise, shall Manufacturer be liable for in- cidental, special, or consequential damages. Manufacturer’s employees or representatives’

ORAL OR OTHER WRITTEN STATEMENTS DO NOT CONSTITUTE WARRANTIES, shall not be relied upon by Purchaser, and are not a part of the contract for sale or this limited war- ranty. This Limited Warranty states the entire obligation of Manufacturer with respect to the Product. If any part of this Limited Warranty is determined to be void or illegal, the remainder shall remain in full force and effect.

PS-PRO II specifications

service

Before returning any equipment for repair, please be sure that it is adequately packed and cush- ioned against damage in shipment, and that it is insured. We suggest that you save the original packaging and use it to ship the product for servicing. Also, please enclose a note with your name, address, phone number and a description of the problem.

NOTE: All equipment being returned for repair must have a Return Authorization (RA) Number. To get an RA Number, please call the Furman Service Department, (707) 763-1010, Ext. 120 or 121, between 8 am and 5 pm U.S. Pacific Time. Please display your RA Number prominently on the front of all packages.

Current Rating:

20 Amps (2400 Watts at 120 VAC)

 

 

(16 Amps for "E" version)

 

Input Voltage:

85 to 264 VAC without damage

 

Delay Intervals:

Total elapsed ON or OFF delay time adjustable

 

 

from 1-60 seconds, with a single trimpot

 

ON Sequence:

-Delay 1 outlets go on immediately with switch.

 

 

-Delays between outlets 1 and 2, and 2 and 3,

 

 

adjustable from 1-60 seconds each

 

OFF Sequence:

-Delay 3 outlets go off immediately with switch.

 

 

-Delays between outlets 3 and 2, and 2 and 1,

 

 

same as ON delays

 

Remote Switch:

Screw terminals, 2 for switch, 2 additional for

 

 

optional LED (22 ga. minimum)

 

Spike Protection Modes:

Line to neutral, zero ground leakage

 

Spike Clamping Voltage:

188 Vpk @ 3,000 amps, (133 VAC RMS)

 

[“E” Version: 376 Vpk (266 VAC RMS)]

 

Response Time:

1 nanosecond

 

Maximum Surge Current:

6,500 amps

 

Dimensions:

1.75” H x 19” W x 10.5” D.

 

Weight:

12 lbs.

 

Construction:

Steel chassis, .125” brushed and black anodized

 

 

aluminum front panel; glass epoxy printed circuit boards

 

Power Consumption:

11 watts

 

Safety Agency Listings:

CE, NRTL-C

 

Over Voltage Shutdown:

US: 140V HI, 80V LO

 

 

E: 280V HI, 150V LO

 

Optional:

220/240V Versions (units with “E” suffix only) are

10

 

intended for use in countries with nominal 220 to

Image 11
Contents PS PRO II Power Conditioner / sequencer Introduction FeaturesDescription Installation recommendationsLocal control Power Sequencing FeaturesOn or off sequencing Momentary vs. maintained contact switching Remote controlFront Panel Faults-for example, accidental connection toRear Panel Momentary Mode Maintained ModeStatus terminal Multiple unitsFlashing delay 1 indicator Three year limited warrantyCE, NRTL-C ServiceFurman Sound, LLC