The D-Series is an entirely different type of instrument than conventional temperature measuring devices. Designed specifically for the highest possible accuracy, it is the only infrared instrument which can be certified as to NIST-tracable accuracy on real surfaces of unknown emissivity, while completely free of contact errors and heat sinking errors of contact devices.

Actual measurement area is in the center, well away from the area contacted by the edge of the cone.

Recessed cone traps all emitted surface radiation, and blocks out any radiation from environment.

Only a thin lip of material actually contacts the target, thus minimizing heat transfer.

Reflective cone automatically corrects for emissivity variations by creating an actual blackbody at the precise location of measurement.

Figure 1. Unique Automatic Emissivity Compensation System (AECS) produces accurate temperatures everywhere the infrared probe is placed, by creating its own blackbody.

1. Emissivity errors

The true emissivity of a surface is known only approximately. Conventional IR devices without Exergen’s Automatic Emissivity Compensation System can only display an approximate temperature over their entire temperature range.

The “accuracy” specifications given by most manufacturers are only for a “black body” calibration and do not hold outside laboratory conditions. Black body calibrations do not include emissivity shifts, ambient change effects on the target, and other phenomena that introduce significant errors.

Effect of Emissivity on Temperature Reading for a

500°F (260°C) Target in 70°F (21°C) ambient

550

 

 

D-Series using marker

290

 

 

 

 

500

 

 

 

 

 

450

 

 

D-Series w/o marker

deg C

deg F

 

 

 

400

 

 

 

 

200

350

 

Conventional Infrared

 

 

300

 

 

 

 

150

1

0.8

0.6

0.4

0.2

0

Non-metals and Oxides

Emissivity

Clean Metals

 

 

 

 

 

Figure 2. D-Series is accurate over a wide emissivity range, sufficient to include all non-metals. If a marker (or any other non-metal coating) is used, the D-series is accurate on clean metals as well. Conventional IR devices have considerable inaccuracy.

2. Emissivity shift errors

Even if an IR “gun” is set to the correct emissivity to read a surface

accurately at a particular temperature, it does not mean that the IR ε “gun” will read the same target correctly at other temperatures.

Emissivity of virtually all surfaces changes with temperature. A common assumption for conventional IR thermometry is that emissivity is constant with changes in target surface temperature. Real materials do not have this characteristic.

Actual emissivity

Conventional IR assumption

Temperature

51 Water Street, Watertown, MA 02172 USA

800-422-3006617-923-9900 • Fax 617-923-9911

Image 2
Contents Microscanner Series Handheld IR Scanners Background reflection errors Infrared Psychrometry Microscanner E-Series Series Handheld IR Scanners Specifications

D-Series specifications

The Exergen D-Series infrared thermometers represent a significant advancement in the field of non-contact temperature measurement. Designed with both accuracy and usability in mind, these devices are well-suited for various applications, including clinical settings, industrial environments, and home use.

One of the standout features of the Exergen D-Series is its highly accurate infrared technology. Utilizing patented technology, the D-Series provides reliable temperature readings without the need for direct contact. This is particularly beneficial in medical environments where hygiene is a top priority, allowing for swift temperature checks while minimizing the risk of cross-contamination.

The D-Series employs a unique scanning method that allows it to measure the temperature of the temporal artery in the forehead. This results in readings that are not only quick—often taking only a second—but also precise, providing users with confidence in their measurements. The device has been clinically validated against other temperature measurement methods to ensure its accuracy, which is crucial for effective patient care and monitoring.

Another important characteristic of the D-Series is its user-friendly design. The thermometer is lightweight and ergonomically shaped, making it easy to handle and maneuver. Its large, backlit display allows for easy reading in various lighting conditions, and it can store multiple readings, which is beneficial for tracking temperature changes over time.

Additionally, the D-Series incorporates advanced features such as fever alerts, which provide audible notifications when a temperature reading exceeds a predetermined threshold. This feature is especially useful in pediatric care, enabling caregivers to respond promptly to potential fever situations.

The Exergen D-Series is also designed with efficiency in mind. It requires minimal calibration and maintenance, making it an ideal choice for busy healthcare environments. The device is powered by long-lasting batteries, further enhancing its practicality for continuous use.

In conclusion, the Exergen D-Series infrared thermometer showcases a perfect blend of advanced technology, ease of use, and practical functionality. Its accuracy, design, and additional features make it a valuable tool across various settings, providing users with reliable temperature readings that contribute to better health outcomes and overall well-being. Whether in a clinic, workplace, or at home, the D-Series stands out as a dependable solution for accurate temperature measurement.